超声造影联合卵巢-附件报告和数据系统超声风险分层对附件肿块的诊断效能:系统评价与Meta分析
该系统评价与Meta分析检索PubMed、Web of Science、Embase和Cochrane Library,纳入5篇文献共598例患者,评估超声造影联合O-RADS对附件肿块的诊断准确性。合并敏感度为0.95(95%CI:0.91-0.98),特异度为0.86(95%CI:0.79-0.91),AUC为0.97(95%CI:0.95-0.98),联合方案的合并AUC和诊断比值比优于单独O-RADS超声。作者认为O-RADS联合超声造影可提高卵巢附件肿块的诊断准确性。
要点
- 超声造影联合O-RADS诊断附件肿块合并敏感度0.95、特异度0.86、AUC 0.97。
- 联合方案合并AUC与诊断比值比优于单独O-RADS超声。
- 纳入5篇文献共598例患者,采用QUADAS-2评价质量与偏倚可能。
核心结论
- O-RADS联合超声造影可提高卵巢附件肿块的诊断准确性。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Web of Science、Embase和Cochrane Library,纳入5篇文献共598例患者,采用QUADAS-2评价文献质量与偏倚可能,使用STATA 12.0软件进行统计分析。
诊断标准与关键数值
- 超声造影联合O-RADS诊断附件肿块的合并敏感度0.95(95%CI:0.91-0.98)、特异度0.86(95%CI:0.79-0.91)、阳性似然比6.81(95%CI:4.61-10.08)、阴性似然比0.05(95%CI:0.03-0.11)、诊断比值比111.30(95%CI:65.32-189.65)、AUC 0.97(95%CI:0.95-0.98)。
临床应用与阅片要点
- 作者认为O-RADS联合超声造影可提高卵巢附件肿块的诊断准确性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: A number of studies have reported that contrast-enhanced ultrasound (CEUS) imaging might be used for the early diagnosis of adnexal masses. A meta-analysis was performed to evaluate the diagnostic accuracy of CEUS combined with Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound risk stratification for adnexal masses.
MATERIALS AND METHODS: Related articles were retrieved from PubMed, Web of Science, Embase, and the Cochrane Library in strict accordance with established standards, and data (including true positive, false positive, false negative, and true negative values) was extracted from the original articles. The Quality Assessment of Diagnostic Accuracy Studies 2 was used to evaluate the quality of articles and the possibility of bias. STATA 12.0 software was used to perform statistical analysis.
RESULTS: Five articles that included 598 patients were analyzed in this meta-analysis. The pooled sensitivity and specificity of CEUS combined with O-RADS for the diagnosis of adnexal masses were 0.95 (95% confidence interval [CI]: 0.91-0.98) and 0.86 (95% CI: 0.79-0.91). Moreover, the positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), and area under the curve (AUC) were 6.81 (95% CI: 4.61-10.08), 0.05 (95% CI: 0.03-0.11), 111.30 (95% CI: 65.32-189.65), and 0.97 (95% CI: 0.95-0.98), respectively. The pooled AUC and DOR for the detection of CEUS combined with O-RADS were superior to O-RADS US.
CONCLUSION: Our findings revealed that O-RADS combined with CEUS can improve the diagnostic accuracy of ovarian adnexal masses.
引用
- Yi YY, Li C, Zhu WJ, et al. Diagnostic performance of contrast-enhanced ultrasound (CEUS) combined with Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound risk stratification for adnexal masses: a systematic review and meta-analysis. Clin Radiol. 2024. PMID: 38942707. doi:10.1016/j.crad.2024.05.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。