文献速递妇产影像泌尿生殖US

超声造影联合IOTA简单规则与O-RADS鉴别含实性成分卵巢良恶性肿块的诊断效能

Differentiating Benign From Malignant Ovarian Masses With Solid Components: Diagnostic Performance of CEUS Combined With IOTA Simple Rules and O-RADS.
PubMed 文献 · Ultrasound Med Biol · 2024-06-13

本研究为两中心回顾性研究,纳入2018年1月至2023年2月86例女性共94个卵巢病灶,对含实性成分者行超声造影(CEUS)并应用IOTA简单规则(SR)与O-RADS分类。SR与O-RADS特异度较低,联合CEUS后敏感度、特异度及AUC均提高。

要点

  • 含实性成分卵巢肿块中,IOTA SR与O-RADS单独应用特异度偏低。
  • CEUS联合SR后AUC由0.783升至0.904,联合O-RADS后AUC由0.641升至0.871。
  • 联合CEUS可提高含实性成分卵巢肿块良恶性鉴别的诊断效能。

核心结论

  • IOTA SR与O-RADS在鉴别含实性成分的卵巢良恶性病变时特异度相对较低,联合CEUS可显著提高其诊断效能。

研究设计与样本

  • 两中心回顾性研究,纳入86例女性共94个卵巢病灶,收集时间为2018年1月至2023年2月;对超声显示实性成分的病灶行CEUS,并回顾性分析CEUS图像,应用IOTA术语、IOTA SR与O-RADS分类。

关键影像表现/征象

  • 良恶性病灶在开始增强时间、达峰强度时间及达峰强度与子宫肌层比较三项参数上差异有统计学意义;CEUS评分将良性病灶定为0分、恶性病灶定为3分。

诊断标准与关键数值

  • 在可应用SR的60个病灶中,SR敏感度0.900、特异度0.667、AUC 0.783;O-RADS敏感度1.000、特异度0.283、AUC 0.641;SR联合CEUS敏感度0.917、特异度0.891、AUC 0.904;O-RADS联合CEUS敏感度0.958、特异度0.783、AUC 0.871。

临床应用与阅片要点

  • 对含实性成分的卵巢肿块,可应用IOTA SR与O-RADS分类,并联合CEUS评分以提高良恶性鉴别诊断效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to apply the International Ovarian Tumor Analysis (IOTA) Simple Rules (SR), the Ovarian-Adnexal Reporting and Data System (O-RADS) and contrast-enhanced ultrasound (CEUS) in an identical cohort of Chinese patients and to analyze their performance in discrimination of ovarian masses with solid components.

METHODS: This was a two-center retrospective study that included a total of 94 ovarian lesions in 86 women enrolled from January 2018 to February 2023. The lesions were classified by using the IOTA terminology and CEUS was performed for the lesions exhibiting solid components on ultrasonography, IOTA SR and O-RADS were applied, and CEUS images were analyzed retrospectively. We assessed the time to wash-in, time to peak intensity (PI), PI compared to myometrium, and time to wash-out, and observed statistically significant differences between benign and malignant lesions in the first three parameters. CEUS characteristics were employed to determine CEUS scores for benign (score 0) and malignant (score 3) lesions. Subsequently, the lesions were reassessed based on the IOTA SR and O-RADS classifications and CEUS scores. The sensitivity, specificity, and area under the receiver-operating-characteristics curve (AUC) of the different models were also determined.

RESULTS: Among the 94 ovarian lesions, 46 (48.9%) were benign and 48 (51.1%) were malignant. It was found that in the 60 lesions to which the SR could be applied, the sensitivity, specificity, and AUC was 0.900, 0.667, and 0.783, respectively. The sensitivity, specificity, and AUC of O-RADS was observed to be 1.000, 0.283 and 0.641, respectively. When SR and O-RADS were combined with CEUS, their sensitivity, specificity, and AUC values were increased to 0.917, 0.891, 0.904, and 0.958, 0.783, 0.871, respectively.

CONCLUSION: IOTA SR and O-RADS exhibited relatively low specificity in differentiating malignant from benign ovarian lesions with the solid components, and their diagnostic performance can be significantly improved when combined with CEUS.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Lu B, He W, Liu C, et al. Differentiating Benign From Malignant Ovarian Masses With Solid Components: Diagnostic Performance of CEUS Combined With IOTA Simple Rules and O-RADS. Ultrasound Med Biol. 2024. PMID: 38876911. doi:10.1016/j.ultrasmedbio.2024.05.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。