文献速递妇产影像介入US

HIFU消融对局部复发子宫肌瘤组织病理学特征的影响

The Impact of HIFU Ablation on the Histopathological Features of Locally Recurrent Fibroids Tissue Post-HIFU Treatment.
PubMed 文献 · Ultrasound Med Biol · 2024-06-18

前瞻性纳入2021年1月1日至2023年7月1日在中国一所教学医院因子宫肌瘤行经腹子宫切除术或肌瘤剔除术的患者,将HIFU消融后局部复发再手术者设为HIFU组、未行HIFU消融者设为对照组,比较HE、Masson及免疫组化染色的平滑肌细胞计数、胶原含量、微血管计数及ER、PR表达。结果显示两组上述指标均无显著差异(p > 0.05),结论认为HIFU消融不影响局部复发肌瘤组织的病理特征。

要点

  • HIFU组与对照组局部复发肌瘤的平滑肌细胞计数、胶原含量、微血管计数及ER、PR表达均无显著差异(p > 0.05)。
  • HIFU组平滑肌细胞计数337.68/视野、胶原含量46.06%、微血管计数13.66/视野。
  • 对照组平滑肌细胞计数328.52/视野、胶原含量41.69%、微血管计数14.08/视野。

核心结论

  • HIFU消融对局部复发子宫肌瘤组织的病理特征无影响,是一种理想的非侵入性治疗选择。

研究设计与样本

  • 前瞻性研究,纳入2021年1月1日至2023年7月1日在中国一所教学医院因子宫肌瘤行经腹子宫切除术或肌瘤剔除术的患者,HIFU消融后局部复发再手术者为HIFU组、未行HIFU消融者为对照组。

关键影像表现/征象

  • HIFU组与对照组平滑肌细胞计数分别为337.68/视野和328.52/视野,差异无统计学意义(p > 0.05)。
  • HIFU组与对照组胶原含量分别为46.06%和41.69%,差异无统计学意义(p > 0.05)。
  • HIFU组与对照组微血管计数分别为13.66/视野和14.08/视野,差异无统计学意义(p > 0.05)。
  • HIFU组与对照组ER评分分别为6.9和7.47,PR评分分别为7.3和7.56,差异均无统计学意义(p > 0.05)。

临床应用与阅片要点

  • 作者认为HIFU消融不影响局部复发肌瘤组织的病理特征,是理想的非侵入性治疗选择。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the impact of high-intensity focused ultrasound (HIFU) ablation on the histopathological features of locally recurrent fibroids tissue.

METHODS: Patients who underwent transabdominal hysterectomy or myomectomy for uterine fibroids from January 1, 2021 to July 1, 2023 at a teaching hospital in China were enrolled in this prospective study. The patients who underwent surgery for local recurrence of uterine fibroids after HIFU ablation were categorized as the HIFU group, and patients who had not undergone HIFU ablation for uterine fibroids were the control group. Hematoxylin-eosin (HE) staining, Masson staining, and immunohistochemical staining were performed to analyze the counts of smooth muscle cells (SMCs), collagen content, microvascular count, and the expression levels of estrogen receptor (ER) and progesterone receptor (PR) in the fibroid tissue specimens.

RESULTS: The mean SMC counts in the HIFU and control groups were 337.68/field and 328.52/field respectively. The mean collagen content in the HIFU group and control group were 46.06% and 41.69% respectively. The mean microvessel counts in the HIFU group and control group were 13.66/field and 14.08/field respectively. The mean ER scores in the HIFU and control groups were 6.9 and 7.47 respectively, and the mean PR scores were 7.3 and 7.56 respectively. Overall, there were no significant differences in the SMC counts, collagen content, microvascular counts, and the ER and PR expression levels between the HIFU group and control group (p > 0.05).

CONCLUSIONS: HIFU ablation has no effect on the pathological characteristics of local recurrent fibroid tissue, and is an ideal non-invasive treatment option.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhang P, Xie L, Chen J, et al. The Impact of HIFU Ablation on the Histopathological Features of Locally Recurrent Fibroids Tissue Post-HIFU Treatment. Ultrasound Med Biol. 2024. PMID: 38897842. doi:10.1016/j.ultrasmedbio.2024.05.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。