PubMed 文献 · Radiology · 2024-01-01

这项前瞻性研究纳入101例疑似子宫肿瘤的成年患者,在MRI与MR弹性成像上测量肿瘤硬度(c)和黏度(φ),以子宫切除标本病理评估LVSI为参考标准。LVSI阳性组肿瘤硬度高于阴性组(中位4.1 m/sec vs 2.2 m/sec,P < .001),将肿瘤硬度加入临床-影像模型后预测LVSI的AUC达0.93,优于临床-影像模型(AUC 0.77,P = .003)。

要点

  • LVSI阳性组肿瘤硬度中位4.1 m/sec,高于LVSI阴性组的2.2 m/sec(P < .001)。
  • 联合模型预测LVSI的AUC为0.93,优于临床-影像模型(AUC 0.77,P = .003)。
  • MR弹性成像模型预测LVSI的AUC为0.89,与联合模型相比无显著差异(P = .06)。

核心结论

  • 将MR弹性成像测量的肿瘤硬度加入临床-影像模型,可改善对子宫内膜癌患者LVSI的预测。

研究设计与样本

  • 前瞻性研究,纳入2022年10月至2023年7月连续成人疑似子宫肿瘤患者101例,均行MRI与MR弹性成像,以子宫切除标本病理评估LVSI为参考标准。

关键影像表现/征象

  • 在T2加权幅度图上勾画的感兴趣区复制到MR弹性成像图像上,用于计算c(硬度,单位米每秒)和φ(黏度,单位弧度)值。
  • LVSI阳性组肿瘤硬度中位4.1 m/sec(IQR 3.2-4.6 m/sec),高于LVSI阴性组中位2.2 m/sec(IQR 2.0-2.8 m/sec),P < .001。

诊断标准与关键数值

  • 肿瘤体积、癌抗原125水平和肿瘤硬度与LVSI阳性相关,校正比值比范围1.01-9.06,P值范围<.001-.04。
  • 联合模型预测LVSI的AUC为0.93,优于临床-影像模型(AUC 0.77,P = .003),与MR弹性成像模型(AUC 0.89)性能相似(P = .06)。

临床应用与阅片要点

  • LVSI阳性组29例(中位年龄54岁,IQR 49-60岁),LVSI阴性组72例(中位年龄53岁,IQR 48-62岁)。
  • MR弹性成像测量肿瘤硬度可作为无创预测子宫内膜癌LVSI的补充指标,联合临床-影像模型可提高预测性能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Pathologic lymphovascular space invasion (LVSI) is associated with poor outcome in endometrial cancer. Its relationship with tumor stiffness, which can be measured with use of MR elastography, has not been extensively explored. Purpose To assess whether MR elastography-based mechanical characteristics can aid in the noninvasive prediction of LVSI in patients with endometrial cancer. Materials and Methods This prospective study included consecutive adult patients with a suspected uterine tumor who underwent MRI and MR elastography between October 2022 and July 2023. A region of interest delineated on T2-weighted magnitude images was duplicated on MR elastography images and used to calculate c (stiffness in meters per second) and φ (viscosity in radians) values. Pathologic assessment of hysterectomy specimens for LVSI served as the reference standard. Data were compared between LVSI-positive and -negative groups with use of the Mann-Whitney U test. Multivariable logistic regression was used to determine variables associated with LVSI positivity and develop diagnostic models for predicting LVSI. Model performance was assessed with use of area under the receiver operating characteristic curve (AUC) and compared using the DeLong test. Results A total of 101 participants were included, 72 who were LVSI-negative (median age, 53 years [IQR, 48-62 years]) and 29 who were LVSI-positive (median age, 54 years [IQR, 49-60 years]). The tumor stiffness in the LVSI-positive group was higher than in the LVSI-negative group (median, 4.1 m/sec [IQR, 3.2-4.6 m/sec] vs 2.2 m/sec [IQR, 2.0-2.8 m/sec]; P < .001). Tumor volume, cancer antigen 125 level, and tumor stiffness were associated with LVSI positivity (adjusted odds ratio range, 1.01-9.06; P range, <.001-.04). The combined model (AUC, 0.93) showed better performance for predicting LVSI compared with clinical-radiologic model (AUC, 0.77; P = .003) and similar performance to the MR elastography-based model (AUC, 0.89; P = .06). Conclusion The addition of tumor stiffness as measured at MR elastography into a clinical-radiologic model improved prediction of LVSI in patients with endometrial cancer. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ehman in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Long L, Liu M, Deng X, et al. Tumor Stiffness Measurement at Multifrequency MR Elastography to Predict Lymphovascular Space Invasion in Endometrial Cancer. Radiology. 2024. PMID: 38832881. doi:10.1148/radiol.232242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。