文献速递妇产影像技术与安全MR

压缩SENSE加速子宫3D T2加权成像的多中心研究

Acceleration of uterine 3D T2-weighted imaging by compressed SENSE-a multicentre study.
PubMed 文献 · Br J Radiol · 2024-01-01

该多中心研究纳入91名女性志愿者,评估压缩SENSE不同加速因子及不同脂肪抑制程度对子宫各向同性高分辨率3D T2加权成像质量的影响。结果显示加速因子CS5结合中度脂肪抑制图像质量最高且扫描时间最短,被推荐用于常规女性盆腔3D-ISO-T2WI扫描。

要点

  • CS5加速因子图像主观评分最高且扫描时间最短,推荐用于常规子宫3D-ISO-T2WI。
  • CS3、CS4、CS5图像信噪比和对比噪声比最高,其中CS5扫描时间最短。
  • 中度脂肪抑制图像主观评分最高,不同脂肪抑制程度间信噪比和对比噪声比无显著差异。

核心结论

  • 推荐CS5加速因子联合中度脂肪抑制用于常规女性盆腔3D各向同性高分辨率T2加权成像扫描。

研究设计与样本

  • 多中心研究,共纳入91名女性志愿者,其中44名接受不同CS加速因子(SENSE3、CS3、CS4、CS5、CS6、CS7)的子宫矢状位3D-ISO-T2WI扫描,51名接受不同脂肪抑制程度(无、轻度、中度、重度)的扫描,4名同时接受两组扫描;使用3.0T MRI设备,采用3分制主观评分及信噪比、对比噪声比、子宫肌层信噪比进行客观评价。

诊断标准与关键数值

  • CS3、CS4、CS5加速因子图像的信噪比和对比噪声比最高,其中CS5扫描时间最短且主观评分最高之一。
  • 不同脂肪抑制程度图像的信噪比和对比噪声比无显著差异,中度脂肪抑制图像主观评分最高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To find the optimal acceleration factor (AF) of the compressed SENSE (CS) technique for uterine isotropic high-resolution 3D T2-weighted imaging (3D-ISO-T2WI).

METHODS: A total of 91 female volunteers from the First Affiliated Hospital of Dalian Medical University, Chu Hsien-I Memorial Hospital and Tianjin Institute of Endocrinology, and The Fourth Hospital of Harbin were recruited. A total of 44 volunteers received uterus sagittal 3D-ISO-T2WI scans on 3.0T MRI device with different CS AFs (including SENSE3, CS3, CS4, CS5, CS6, and CS7), 51 received 3D-ISO-T2WI scans with different degrees of fat suppression (none, light, moderate, and severe), while 4 volunteers received both series of scans. Image quality was subjectively evaluated with a 3-point scoring system. Junction zone signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and myometrial SNR were also calculated. Intraclass correlation coefficients were used to analyse the consistency of the measurement results by 2 observers. Analysis of variance test or Friedman rank sum test was used to compare the differences in subjective scores, SNR, and CNR under different AFs/different degrees of fat suppression.

RESULTS: Images by AFs of CS3, CS4, and CS5 had the highest SNR and CNR. Among them, CS5 had the shortest scan time. CS5 also had one of the highest subjective scores. There was no significant difference in SNR and CNR among images acquired with different degrees of fat suppression. Also, images with moderate fat suppression had the highest subjective scores.

CONCLUSION: The CS5 combined with moderate fat suppression is recommended for routine female pelvic 3D-ISO-T2WI scan.

ADVANCES IN KNOWLEDGE: The CS5 has the highest image quality and has the shortest scan time, which is the best AF. Moderate fat suppression has the highest subjective scores. The CS5 and moderate fat suppression are the best combination for a female pelvic 3D-ISO-T2WI scan.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Song Q, Ma C, Tian S, et al. Acceleration of uterine 3D T2-weighted imaging by compressed SENSE-a multicentre study. Br J Radiol. 2024. PMID: 38885406. doi:10.1093/bjr/tqae113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。