文献速递腹部技术与安全CT

物质密度双能CT图像:腹膜癌早期诊断中的附加价值:原创研究

Material density dual-energy CT images: value added in early diagnosis of peritoneal carcinomatosis : Original research.
PubMed 文献 · Abdom Radiol (NY) · 2024-06-25

研究纳入30例腹膜癌患者共120次腹部双能CT扫描,比较65 keV单独与65 keV+物质密度图像诊断腹膜癌的价值。联合物质密度图像总体敏感度89% vs 84%(p=0.11),有经验阅片者敏感度98% vs 90%(p=0.02),并可使额外13-23%患者获得更早诊断。联合图像诊断信心、病灶清晰度及对比噪声比更高,阅片者间一致性中等。

要点

  • 65 keV+物质密度图像较65 keV单独使有经验阅片者诊断敏感度从90%提升至98%。
  • 联合物质密度图像可使额外13-23%患者获得腹膜癌更早诊断。
  • 联合物质密度图像对比噪声比1.7±0.5,高于65 keV图像的0.1±0.02。

核心结论

  • 物质密度图像可实现对腹膜癌更早且更好的检出,获益程度因阅片者经验和患者体型而异。

研究设计与样本

  • 纳入30例(60±13岁;24例女性)经多次腹部双能CT扫描检出腹膜癌的患者,每例患者4次表现不同的双能CT扫描共120次扫描行定性与定量分析;3名放射科医师独立评价65 keV单独与65 keV+物质密度图像,采用5点Likert量表评价诊断信心、病灶清晰度、锐利度/勾画及图像质量,并行对比噪声比定量估算;采用Wilcoxon符号秩检验和比值比计算比较两种方案,Kappa系数评价阅片者间一致性,P<0.05为有统计学意义。

诊断标准与关键数值

  • 65 keV+物质密度图像诊断腹膜癌总体敏感度89%(95%CI:84,92),65 keV单独为84%(95%CI:78,88),p=0.11;有经验阅片者65 keV+物质密度图像敏感度98%(95%CI:93,100)vs 65 keV单独90%(95%CI:83,94),p=0.02;按患者计算,使用物质密度图像使额外13-23%患者获得腹膜癌更早诊断,亚组分析中BMI≤29.9 kg/m2患者获益尤其明显;对比噪声比物质密度图像1.7±0.5 vs 65 keV图像0.1±0.02,p<0.001;两方案判断腹膜癌的阅片者间一致性均为中等(κ=0.58和κ=0.47)。

临床应用与阅片要点

  • 有经验阅片者采用65 keV+物质密度图像可提高腹膜癌诊断信心、病灶清晰度和锐利度(p<0.001);对BMI≤29.9 kg/m2患者,物质密度图像带来的更早诊断获益尤其明显。

局限性

  • 总体敏感度提升(89% vs 84%)未达统计学显著(p=0.11)。
  • 两方案阅片者间一致性均为中等(κ=0.58和κ=0.47)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the value of material density (MD) images generated from a rapid kilovoltage-switching dual-energy CT (rsDECT) in early detection of peritoneal carcinomatosis (PC).

MATERIALS AND METHODS: Thirty patients (60 ± 13 years; 24 women) with PC detected on multiple abdominal DECT scans were included. Four separate DECTs with varying findings of PC from each patient were used for qualitative/quantitative analysis, resulting in a total of 120 DECT scans (n = 30 × 4). Three radiologists independently reviewed DECT images (65 keV alone and 65 keV + MD) for diagnosis of PC (diagnostic confidence, lesion conspicuity, sharpness/delineation and image quality) using a 5-point Likert scale. Quantitative estimation of contrast-to-noise ratio (CNR) was done. Wilcoxon signed-rank test and Odds ratio calculation were used to compare between the two protocols. Inter-observer agreement was evaluated using Kappa coefficient analysis. P values < 0.05 were considered statistically significant.

RESULTS: 65 keV + MD images showed a slightly higher sensitivity (89%[95%CI:84,92]) for PC detection compared with 65 keV images alone without statistical significance (84%[95%CI:78,88], p = 0.11) with the experienced reader showing significant improvement (98%[95%CI:93,100] vs. 90%[95%CI:83,94], p = 0.02). On a per-patient basis, use of MD images allowed earlier diagnosis for PC in an additional 13-23% of patients. On sub-group analysis, earlier diagnosis of PC was particularly beneficial in patients with BMI ≤ 29.9 kg/m2. 65 keV + MD images showed higher diagnostic confidence, lesion conspicuity, and lesion sharpness for the experienced reader (p < 0.001). CNR was higher in MD images (1.7 ± 0.5) than 65 keV images (0.1 ± 0.02, p < 0.001). All readers showed moderate interobserver agreement for determining PC by both protocols (κ = 0.58 and κ = 0.47).

CONCLUSION: MD images allow earlier and improved detection of PC with the degree of benefit varying based on reader experience and patient body habitus.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Pisuchpen N, Lennartz S, Parakh A, et al. Material density dual-energy CT images: value added in early diagnosis of peritoneal carcinomatosis : Original research. Abdom Radiol (NY). 2024. PMID: 38916617. doi:10.1007/s00261-024-04451-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。