自由呼吸高分辨率、无交换及运动校正水脂分离在儿童腹部MRI中的应用
研究纳入22例儿童(4.2±2.3岁),在3T扫描仪上比较3点Dixon径向VIBE序列(含6峰脂肪模型与软门控运动校正)与常规2点Dixon技术的图像质量。结果显示新方法整体Likert评分显著优于常规技术(P<0.05),2点Dixon在14/22例出现水脂交换伪影而新方法未出现,图像锐度显著改善,代价是额外约1分钟采集时间。
要点
- 3点Dixon径向VIBE联合6峰脂肪模型与软门控运动校正可消除水脂交换伪影。
- 新方法整体图像质量评分显著优于常规2点Dixon(P<0.05),图像锐度显著改善。
- 新方法额外增加约1分钟采集时间,作者认为有潜力替代常规2点Dixon技术。
核心结论
- 高分辨率黄金角径向VIBE 3点Dixon采集联合6峰脂肪模型与软门控运动校正可改善图像质量,代价是额外约1分钟采集时间,作者认为该技术有潜力替代常规2点Dixon技术。
研究设计与样本
- 研究纳入22例儿童患者(4.2±2.3岁),在3T扫描仪上分别采用常规腹部方案和3点Dixon径向VIBE序列行腹部MRI,由3名儿科放射科医师在PACS工作站上阅片评分。
关键影像表现/征象
- 使用2点Dixon技术的22例患者中有14例观察到水脂交换伪影,使用所提出的方法时该伪影未出现。
- 所提出方法生成的图像整体Likert评分显著优于常规2点Dixon技术重建的图像(P<0.05)。
- 使用所提出框架的图像锐度显著改善。
诊断标准与关键数值
- 由3名儿科放射科医师采用5点Likert量表对主观图像质量和水脂交换伪影进行评分。
- 采用Laplacian方差(VoL)客观量化重建图像的锐度。
临床应用与阅片要点
- 作者认为该技术有潜力替代常规2点Dixon技术。
- 作者指出在较小患者中,高质量水脂分离与精细结构清晰显示对诊断准确性至关重要。
- 新方法额外增加约1分钟采集时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The T1-weighted GRE (gradient recalled echo) sequence with the Dixon technique for water/fat separation is an essential component of abdominal MRI (magnetic resonance imaging), useful in detecting tumors and characterizing hemorrhage/fat content. Unfortunately, the current implementation of this sequence suffers from several problems: (1) low resolution to maintain high pixel bandwidth and minimize chemical shift; (2) image blurring due to respiratory motion; (3) water/fat swapping due to the natural ambiguity between fat and water peaks; and (4) off-resonance fat blurring due to the multipeak nature of the fat spectrum. The goal of this study was to evaluate the image quality of water/fat separation using a high-resolution 3-point Dixon golden angle radial acquisition with retrospective motion compensation and multipeak fat modeling in children undergoing abdominal MRI.
MATERIALS AND METHODS: Twenty-two pediatric patients (4.2 ± 2.3 years) underwent abdominal MRI on a 3 T scanner with routine abdominal protocol and with a 3-point Dixon radial-VIBE (volumetric interpolated breath-hold examination) sequence. Field maps were calculated using 3D graph-cut optimization followed by fat and water calculation from k-space data by iteratively solving an optimization problem. A 6-peak fat model was used to model chemical shifts in k-space. Residual respiratory motion was corrected through soft-gating by weighting each projection based on the estimated respiratory motion from the center of the k-space. Reconstructed images were reviewed by 3 pediatric radiologists on a PACS (picture archiving and communication systems) workstation. Subjective image quality and water/fat swapping artifact were scored by each pediatric radiologist using a 5-point Likert scale. The VoL (variance of Laplacian) of the reconstructed images was used to objectively quantify image sharpness.
RESULTS: Based on the overall Likert scores, the images generated using the described method were significantly superior to those reconstructed by the conventional 2-point Dixon technique ( P < 0.05). Water/fat swapping artifact was observed in 14 of 22 patients using 2-point Dixon, and this artifact was not present when using the proposed method. Image sharpness was significantly improved using the proposed framework.
CONCLUSIONS: In smaller patients, a high-quality water/fat separation with sharp visualization of fine details is critical for diagnostic accuracy. High-resolution golden angle radial-VIBE 3-point Dixon acquisition with 6-peak fat model and soft-gated motion correction offers improved image quality at the expense of an additional ~1-minute acquisition time. Thus, this technique offers the potential to replace the conventional 2-point Dixon technique.
引用
- Nosrati R, Calakli F, Afacan O, et al. Free-Breathing High-Resolution, Swap-Free, and Motion-Corrected Water/Fat Separation in Pediatric Abdominal MRI. Invest Radiol. 2024. PMID: 38857418. doi:10.1097/RLI.0000000000001092
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。