文献速递心血管外周血管US

肝静脉与上腔静脉血流速度波形分析预测右心房压升高的头对头比较

Head-to-Head Comparison of Hepatic Vein and Superior Vena Cava Flow Velocity Waveform Analyses for Predicting Elevated Right Atrial Pressure.
PubMed 文献 · Ultrasound Med Biol · 2024-06-03

在193例心血管疾病患者中,比较肝静脉收缩期充盈分数(HV-SFF)与上腔静脉收缩期/舒张期前向血流速度峰值比(SVC-S/D)预测右心房压(RAP)升高的诊断效能。SVC-S/D>1.9诊断RAP升高的AUC为0.842,显著高于HV-SFF<55%的0.614(p<0.001),且SVC-S/D在估算RAP基础上提供增量诊断价值。

要点

  • SVC-S/D>1.9诊断RAP升高的AUC为0.842,高于HV-SFF<55%的0.614(p<0.001)。
  • SVC-S/D与RAP呈负相关(r=-0.430,p<0.001),HV-SFF亦呈负相关(r=-0.350,p<0.001)。
  • SVC-S/D在基于下腔静脉形态估算RAP基础上显示增量诊断价值,HV-SFF联合估算RAP未见诊断准确率改变。

核心结论

  • SVC-S/D较HV-SFF能更准确地诊断右心房压升高。

研究设计与样本

  • 研究纳入193例心血管疾病患者,在超声心动图检查后2天内接受心导管检查,测量HV-SFF和SVC-S/D,并以HV-SFF<55%和SVC-S/D<1.9作为RAP升高的判定标准,同时计算FIB-4作为血清肝纤维化标志物。

关键影像表现/征象

  • HV-SFF和SVC-S/D分别可在177例(92%)和173例(90%)患者中测得。
  • 在两者均可测量的161例患者中,HV-SFF与RAP呈负相关(r=-0.350,p<0.001),SVC-S/D与RAP呈负相关(r=-0.430,p<0.001)。

诊断标准与关键数值

  • SVC-S/D>1.9诊断RAP升高的AUC为0.842,HV-SFF<55%诊断RAP升高的AUC为0.614,两者差异p<0.001。
  • 多因素分析显示FIB-4(β=-0.211,p=0.013)和平均RAP(β=-0.319,p<0.001)是HV-SFF的独立决定因素。
  • 多因素分析显示平均RAP(β=-0.471,p<0.001)是SVC-S/D的独立决定因素,而FIB-4不是。
  • HV-SFF<55%联合基于下腔静脉形态估算的RAP时诊断准确率不变,SVC-S/D在估算RAP基础上显示增量诊断价值。

临床应用与阅片要点

  • SVC-S/D>1.9可用于更准确地诊断右心房压升高,HV-SFF<55%的诊断准确率较低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Blood flow in the hepatic veins and superior vena cava (SVC) reflects right heart filling; however, their Doppler profiles are often not identical, and no studies have compared their diagnostic efficacies. We aimed to determine which venous Doppler profile is reliable for detecting elevated right atrial pressure (RAP).

METHODS: In 193 patients with cardiovascular diseases who underwent cardiac catheterization within 2 d of echocardiography, the hepatic vein systolic filling fraction (HV-SFF) and the ratio of the peak systolic to diastolic forward velocities of the SVC (SVC-S/D) were measured. HV-SFF < 55% and SVC-S/D < 1.9 were regarded as elevated RAP. We also calculated the fibrosis 4 index (FIB-4) as a serum liver fibrosis marker.

RESULTS: HV-SFF and SVC-S/D were feasible in 177 (92%) and 173 (90%) patients, respectively. In the 161 patients in whom both venous Doppler waveforms could be measured, HV-SFF and SVC-S/D were inversely correlated with RAP (r = -0.350, p < 0.001; r = -0.430, p < 0.001, respectively). SVC-S/D > 1.9 showed a significantly higher diagnostic accuracy of RAP elevation compared with HV-SFF < 55% (area under the curve, 0.842 vs. 0.614, p < 0.001). Multivariate analyses showed that both FIB-4 (β = -0.211, p = 0.013) and mean RAP (β = -0.319, p < 0.001) were independent determinants of HV-SFF. In contrast, not FIB-4 but mean RAP (β = -0.471, p < 0.001) was an independent determinant of SVC-S/D. The diagnostic accuracy remained unchanged when HV-SFF < 55% was considered in conjunction with the estimated RAP based on the inferior vena cava morphology. Conversely, SVC-S/D showed an incremental diagnostic value over the estimated RAP.

CONCLUSIONS: SVC-S/D enabled a more accurate diagnosis of RAP elevation than HV-SFF.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Murayama M, Kaga S, Onoda A, et al. Head-to-Head Comparison of Hepatic Vein and Superior Vena Cava Flow Velocity Waveform Analyses for Predicting Elevated Right Atrial Pressure. Ultrasound Med Biol. 2024. PMID: 38834491. doi:10.1016/j.ultrasmedbio.2024.05.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。