文献速递胸部CT

肺腺癌同步多发纯磨玻璃结节的 maximal 直径与平均CT值小于孤立性纯磨玻璃结节

Maximal diameters and mean computed tomography (CT) value of synchronous multiple pure ground-glass opacities in lung adenocarcinoma are smaller.
PubMed 文献 · Clin Radiol · 2024-05-10

回顾性比较138例患者中58例孤立性纯磨玻璃结节(SpGGOs)与80例同步多发纯磨玻璃结节(SMpGGOs,共187个)的影像特征。SMpGGOs诊断腺癌的最大直径阈值为5.5 mm(敏感度86.4%,特异度55.6%,AUC 0.777),平均CT值阈值为-615.0 Hu(敏感度61.4%,特异度66.7%,AUC 0.651);SpGGOs对应阈值分别为12.5 mm(敏感度54.5%,特异度100%,AUC 0.851)和-531.9 Hu(敏感度43.2%,特异度100%,AUC 0.724)。作者结论认为SMpGGOs的阈值可能小于SpGGOs。

要点

  • SMpGGOs诊断腺癌的最大直径阈值5.5 mm,低于SpGGOs的12.5 mm。
  • SMpGGOs平均CT值阈值-615.0 Hu,低于SpGGOs的-531.9 Hu。
  • SMpGGOs阈值敏感度较高但特异度较低,SpGGOs阈值特异度达100%。

核心结论

  • SMpGGOs诊断腺癌的最大直径和平均CT值阈值可能小于SpGGOs(5.5 mm vs. 12.5 mm,-615.0 Hu vs. -531.9 Hu)。

研究设计与样本

  • 回顾性研究,纳入2018年8月至2020年6月间XXX机构的患者,分为SpGGOs组(58例,58个结节)和SMpGGOs组(80例,187个结节),比较临床记录、病理特征和影像表现,使用SPSS 21.0分析。

诊断标准与关键数值

  • SMpGGOs诊断腺癌的最大直径阈值为5.5 mm(敏感度86.4%,特异度55.6%,AUC 0.777)。
  • SMpGGOs诊断腺癌的平均CT值阈值为-615.0 Hu(敏感度61.4%,特异度66.7%,AUC 0.651)。
  • SpGGOs诊断腺癌的最大直径阈值为12.5 mm(敏感度54.5%,特异度100%,AUC 0.851)。
  • SpGGOs诊断腺癌的平均CT值阈值为-531.9 Hu(敏感度43.2%,特异度100%,AUC 0.724)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIMS: Synchronous multiple pure ground-glass opacities (SMpGGOs) are observed more commonly. Nevertheless whether characteristics of SMpGGOs are similar to those of solitary pure ground-glass opacities (SpGGOs), remains unknown. This retrospective study aimed to compare radiographic characteristics between SMpGGOs and SpGGOs.

MATERIALS AND METHODS: We retrospectively included patients along with SpGGOs or SMpGGOs at XXX between August 2018 and June 2020. They were enrolled in two groups (SpGGOs and SMpGGOs). The clinical records, pathologic features, and radiographic manifestations of two groups were collected and compared with SPSS 21.0.

RESULTS: 138 patients (58 patients with 58 SpGGOs, 80 patients with 187 SMpGGOs) were evaluated. The threshold values of maximal diameters and mean computed tomography value for adenocarcinoma were 5.5 mm (sensitivity 86.4%, specificity 55.6%, AUC 0.777) and -615.0 Hu in SMpGGOs (sensitivity 61.4%, specificity 66.7%, AUC 0.651) for SMpGGOs, whereas 12.5 mm (sensitivity 54.5%, specificity 100%, AUC 0.851) and -531.9 Hu (sensitivity 43.2%, specificity 100%, AUC 0.724) in SpGGOs.

CONCLUSION: The threshold values of maximal diameters and mean computed tomography value for adenocarcinoma in SMpGGOs may be smaller than those in SpGGOs (5.5 mm vs. 12.5mm, -615.0 Hu vs. -531.9 Hu).

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang L, Zhao L, Zhao W, et al. Maximal diameters and mean computed tomography (CT) value of synchronous multiple pure ground-glass opacities in lung adenocarcinoma are smaller. Clin Radiol. 2024. PMID: 38890050. doi:10.1016/j.crad.2024.05.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。