基于PET影像组学预测非小细胞肺癌EGFR突变状态的跨设备验证
该研究回顾性收集郑州大学第一附属医院和义分院(西门子设备)和东院区(GE设备)核医学科的患者,建立5个逻辑回归模型预测非小细胞肺癌EGFR突变状态,结果显示同设备训练测试的模型AUC高于跨设备模型,影像组学的跨设备通用性在临床实践中不够好。
要点
- 基于PET影像组学预测EGFR突变状态时,同设备模型AUC高于跨设备模型。
- 同设备训练/测试的模型测试集AUC最高为0.73(GE数据集模型)。
- 跨设备通用性不足,临床应用中需注意设备差异对模型性能的影响。
核心结论
- 同设备数据集训练和测试的模型AUC高于不同设备数据集,影像组学的跨设备通用性在临床实践中不够好。
研究设计与样本
- 回顾性研究,收集郑州大学第一附属医院和义分院(西门子设备)和东院区(GE设备)核医学科的患者,建立5个逻辑回归模型,分别用GE数据集、西门子数据集、混合数据集训练测试以及交叉训练测试。
诊断标准与关键数值
- 第1至第5个模型的训练/测试数据集AUC均值分别为0.78/0.73、0.74/0.72、0.75/0.70、0.74/0.65和0.68/0.63。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To validate the inter-equipment generality of the radiomics based on PET images to predict the EGFR mutation status of patients with non-small cell lung cancer.
MATERIALS AND METHODS: Patients were retrospectively collected in the departments of nuclear medicine of Heyi branch (Siemens equipment) and East branch (General Electric (GE) equipment) of the first affiliated hospital of Zhengzhou university. 5 predicting logistic regression models were established. The 1st one was trained and tested by the GE dataset; The 2nd one was trained and tested by the Siemens dataset; The 3rd one was trained and tested by the mixed dataset consisting of GE and Siemens. The 4th one was trained by GE and tested by Siemens; The 5th one was trained by Siemens and tested by GE.
RESULTS: For the 1st ∼ 5th models, the mean values of AUCs for training/testing datasets were 0.78/0.73, 0.74/0.72, 0.75/0.70, 0.74/0.65 and 0.68/0.63, respectively.
CONCLUSION: The AUCs of the models trained and tested on the datasets from the same equipment were higher than those for different equipment. The inter-equipment generality of the radiomics was not good enough in clinical practice.
引用
- Wang B, Bao C, Wang X, et al. Inter-equipment validation of PET-based radiomics for predicting EGFR mutation statuses in patients with non-small cell lung cancer. Clin Radiol. 2024. PMID: 38821756. doi:10.1016/j.crad.2023.12.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。