文献速递胸部CT

能谱CT用于实性T1期非小细胞肺癌N2站淋巴结转移的术前诊断

Spectral CT for preoperative diagnosis of N2 station lymph node metastasis in solid T1 non-small cell lung cancer.
PubMed 文献 · Eur J Radiol · 2024-06-06

回顾性纳入2019年9月至2023年6月60例实性T1期非小细胞肺癌患者共121枚淋巴结(38枚转移),评估双期增强能谱CT参数的诊断价值。转移淋巴结动脉期和静脉期CT40KeV、λHu、nIC、nZeff均低于非转移淋巴结,短轴直径高于非转移淋巴结;短轴直径AUC最高(0.788),联合静脉期λHu和nZeff后AUC升至0.871。

要点

  • 转移淋巴结动脉期和静脉期CT40KeV、λHu、nIC、nZeff均低于非转移淋巴结。
  • 转移淋巴结短轴直径高于非转移淋巴结,诊断AUC为0.788。
  • 短轴直径联合静脉期λHu和静脉期nZeff可将AUC提高至0.871。

核心结论

  • 能谱CT是实性T1期非小细胞肺癌N2站淋巴结转移术前诊断的补充手段,联合参数具有更高的诊断效能。

研究设计与样本

  • 回顾性研究,纳入2019年9月至2023年6月行双期增强CT的60例非小细胞肺癌患者(平均年龄62.85岁±8.49,44例男性),共121枚淋巴结(38枚转移),由2名放射科医师独立测量能谱CT定量参数,行Logistic回归分析和Delong检验。

关键影像表现/征象

  • 原发灶与转移淋巴结动脉期λHu、静脉期λHu差异均无统计学意义(P>0.05)。
  • 原发灶与静脉期λHu在非转移淋巴结间差异有统计学意义(P<0.001)。
  • 转移淋巴结动脉期和静脉期CT40KeV、λHu、nIC、nZeff均低于非转移淋巴结(均P<0.05)。
  • 转移淋巴结短轴直径高于非转移淋巴结(P<0.001)。

诊断标准与关键数值

  • 短轴直径诊断转移淋巴结的AUC最高,为0.788。
  • 短轴直径联合静脉期λHu和静脉期nZeff诊断转移淋巴结的AUC为0.871。

临床应用与阅片要点

  • 阅片时可测量淋巴结短轴直径,并结合静脉期λHu和nZeff综合判断N2站淋巴结转移。
  • 转移淋巴结的动脉期和静脉期CT40KeV、λHu、nIC、nZeff均低于非转移淋巴结,可作为辅助鉴别指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic value of spectral CT for the preoperative diagnosis of N2 station lymph nodes metastasis in solid T1 non-small cell lung cancer (NSCLC).

METHOD: For this retrospective study, dual-phase contrast agent-enhanced CT was performed in patients with NSCLC from September 2019 to June 2023. Quantitative spectral CT parameters measurements were performed by 2 radiologists independently. Logistic regression analysis and Delong test were performed.

RESULTS: 60 NSCLC patients (mean age, 62.85 years ± 8.49, 44men) were evaluated. A total of 121 lymph nodes (38 with metastasis) were enrolled. There was no significant difference in the slope of the spectral Hounsfield unit curve (λHu) on arterial phase (AP) or venous phase (VP) between primary lesions and metastatic lymph nodes (P > 0.05), but significant difference in VP λHu between primary lesions and non-metastatic lymph nodes (P < 0.001). The CT40KeV, λHu, normalized iodine concentration (nIC), normalized effective atomic number (nZeff) measured during both AP and VP were lower in metastatic lymph nodes than in non-metastatic lymph nodes (all P < 0.05). Short-axis diameter (S) of metastatic lymph nodes was higher than non-metastatic lymph nodes (P < 0.001). Area under the curve (AUC) for S performed the highest (0.788) in diagnosing metastatic lymph nodes. When combined with VP λHu, VP nZeff, AUC increased to 0.871.

CONCLUSION: Spectral CT is a complementary means for the preoperative diagnosis of N2 station lymph nodes metastasis in solid T1 NSCLC. The combined parameters have higher diagnostic efficiency.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhu G, Wang JA, Xiao D, et al. Spectral CT for preoperative diagnosis of N2 station lymph node metastasis in solid T1 non-small cell lung cancer. Eur J Radiol. 2024. PMID: 38878500. doi:10.1016/j.ejrad.2024.111553

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。