文献速递胸部技术与安全PETCT

深吸气屏气全身PET/CT显像对胸部18F-FDG高摄取病灶的影响:与自由呼吸对比

The impact of deep-inspiration breath-hold total-body PET/CT imaging on thoracic 18F-FDG avid lesions compared with free-breathing.
PubMed 文献 · Eur J Radiol · 2024-06-03

前瞻性纳入145例患者中137例完成常规自由呼吸300秒PET/CT和30秒深吸气屏气全身PET/CT。深吸气屏气30秒较自由呼吸显著降低肺背景摄取、改善肝脏穹顶PET/CT配准,并提高胸部病灶(尤其下胸部)SUV和肿瘤-背景比,检测敏感度分别为97.9%和99.0%。

要点

  • 深吸气屏气30秒全身PET/CT在临床实践中可行,可降低肺背景摄取并改善配准。
  • 下胸部病灶在深吸气屏气下SUV显著高于自由呼吸300秒,上胸部差异无统计学意义。
  • 深吸气屏气下病灶肿瘤-周围背景比在上、下胸部均显著增高。

核心结论

  • 全身深吸气屏气PET/CT技术临床可行,可降低肺背景摄取、获得更好的配准和病灶定量,尤其在下胸部。

研究设计与样本

  • 前瞻性研究,145例前瞻性入组患者中137例完成常规自由呼吸300秒PET/CT和30秒深吸气屏气全身PET/CT(胸至骨盆低剂量CT);重建全身自由呼吸300秒、自由呼吸30秒和深吸气屏气30秒PET图像,采用Wilcoxon符号秩检验比较。

关键影像表现/征象

  • 深吸气屏气30秒肺SUVmax和SUVmean显著低于自由呼吸。
  • 深吸气屏气30秒肝脏穹顶PET与CT距离显著小于自由呼吸。

诊断标准与关键数值

  • 106例患者共195个可评估病灶,自由呼吸300秒检测敏感度97.9%,深吸气屏气30秒检测敏感度99.0%。
  • 小病灶(n=86)和直径≥1 cm较大病灶(n=91)中,深吸气屏气30秒病灶SUV均显著高于自由呼吸300秒。
  • 下胸部病灶(n=97)深吸气屏气30秒与自由呼吸300秒SUV差异显著(p<0.001),上胸部病灶(n=80)差异无统计学意义(p>0.05)。
  • 病灶肿瘤-周围背景比(TsBR)在上胸部和下胸部均显著增高。

临床应用与阅片要点

  • 深吸气屏气30秒全身PET/CT可用于胸部病灶显像,尤其下胸部病灶的定量评估。
  • 阅片时注意深吸气屏气可降低肺背景摄取并提高下胸部病灶SUV,上胸部病灶SUV与自由呼吸差异无统计学意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate PET/CT registration and quantification accuracy of thoracic lesions of a single 30-second deep-inspiration breath-hold (DIBH) technique with a total-body PET (TB-PET) scanner, and compared with free-breathing (FB) PET/CT.

METHODS: 137 of the 145 prospectively enrolled patients finished a routine FB-300 s PET/CT exam and a 30-second DIBH TB-PET with chest to pelvis low dose CT. The total-body FB-300 s, FB-30 s, and DIBH-30 s PET images were reconstructed. Quantitative assessment (SUVmax and SUVmean of lung and other organs), PET/CT registration assessment and lesion analysis (SUVmax, SUVpeak, SUVmean and tumor-background ratio) were compared with Wilcoxon signed-rank tests.

RESULTS: The SUVmax and SUVmean of the lung with DIBH-30 s were significantly lower than those with FB. The distances of the liver dome between PET and CT were significantly smaller with DIBH-30 s than with FB. 195 assessable lesions in 106 patients were included, and the detection sensitivity was 97.9 % and 99.0 % in FB-300 s, and DIBH-30 s, respectively. For both small co-identified lesions (n = 86) and larger co-identified lesions with a diameter ≥ 1 cm (n = 91), the lesion SUVs were significantly greater with DIBH-30 s than with FB-300 s. Regarding lesion location, the differences of the SUVs for the lesions in the lower thorax area (n = 97, p < 0.001) were significant between DIBH-30 s and FB-300 s, while these differences were not statistically significant in the upper thorax (n = 80, p > 0.05). The lesion tumor-to-surrounding-background ratio (TsBR) was significantly increased, both in the upper and lower thorax.

CONCLUSION: The TB DIBH PET/CT technique is feasible in clinical practice. It reduces the background lung uptake and achieves better registration and lesion quantification, especially in the lower thorax.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Cui Y, Jia J, Yan Q, et al. The impact of deep-inspiration breath-hold total-body PET/CT imaging on thoracic 18F-FDG avid lesions compared with free-breathing. Eur J Radiol. 2024. PMID: 38850723. doi:10.1016/j.ejrad.2024.111549

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。