文献速递外周血管介入胸部CTDSA

支气管动脉颗粒栓塞治疗合并分流的咯血患者的疗效与安全性

Efficacy and safety of particle embolization in bronchial arteries of hemoptysis patients with shunts.
PubMed 文献 · Clin Radiol · 2024-06-08

回顾性单中心研究分析2020年6月至2023年4月312例支气管动脉栓塞术,其中49例存在支气管动脉与非支气管体循环动脉及肺动脉之间的分流。技术成功率98%,术后24小时内所有患者咯血停止或显著减少,临床成功率1个月97.9%、6个月93.9%、1年89.8%,未检测到分流相关并发症。

要点

  • 合并支气管动脉与体循环动脉及肺动脉分流的咯血患者,颗粒栓塞技术成功率98%。
  • 术后24小时内所有患者咯血停止或显著减少,1年临床成功率89.8%。
  • 未检测到分流相关并发症,提示颗粒栓塞在复杂分流病例中安全有效。

核心结论

  • 支气管动脉栓塞术中使用颗粒栓塞是治疗咯血的安全有效方法,尤其适用于支气管动脉与非支气管体循环动脉及肺动脉之间存在复杂分流的病例。

研究设计与样本

  • 回顾性单中心研究,分析2020年6月至2023年4月期间实施的312例支气管动脉栓塞术,患者队列存在支气管动脉与非支气管体循环动脉及肺动脉之间的分流;收集临床特征、CT影像和栓塞操作细节。

诊断标准与关键数值

  • 49例患者检出血管分流,咯血病因包括结核后遗症42.8%、支气管扩张26.5%、活动性结核12.2%、曲霉球8.1%、细菌性肺炎4.1%、肺癌4.1%、非结核分枝杆菌感染2%。
  • 技术成功率98%,152支 identified 血管中149支成功栓塞。
  • 临床成功率:1个月97.9%,6个月93.9%,1年89.8%。
  • 未检测到分流相关并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: This study assesses the safety and efficacy of particle embolization during bronchial artery embolization (BAE) in patients with shunts between bronchial and non-bronchial systemic arteries and the pulmonary artery.

METHODS: In this retrospective, single-center study, we analyzed 312 BAE procedures performed from June 2020 to April 2023. The patient cohort had shunts between bronchial and non-bronchial systemic arteries and the pulmonary artery. We meticulously collected and examined comprehensive data, including clinical characteristics, computed tomography (CT) imaging, and embolization procedural details.

RESULTS: Vascular shunts were identified in 49 patients. The etiologies of hemoptysis included post-TB sequelae (42.8%), bronchiectasis (26.5%), active TB (12.2%), aspergilloma (8.1%), bacterial pneumonia (4.1%), lung cancer (4.1%), and non-tuberculous mycobacterial infection (2%). The technical success rate of the procedures was 98%, with 149 out of 152 identified vessels successfully embolized. All patients experienced cessation or significant reduction of hemoptysis within 24 hours following the procedure. The clinical success rates were 97.9% at one month, 93.9% at six months, and 89.8% at one year. No shunt-related complications were detected.

CONCLUSION: BAE with particle embolization is a safe and effective treatment for hemoptysis, particularly in cases with complex shunts between bronchial and non-bronchial systemic arteries and the pulmonary artery.