使用CT影像组学预测肺癌侵袭性组织病理学特征:一项系统综述
该系统综述纳入11项CT影像组学检测肺癌侵袭性组织病理学特征的试验准确性研究,其中10/11来自东亚人群,4/11研究STAS,6/11研究腺癌侵袭性或生长模式,1/11研究LVI。报告准确度范围为0.67至0.94,但由于偏倚风险高和适用性担忧,证据尚不确定影像组学特征能否准确预测这些特征;许多研究因缺乏外部验证被排除,需严格的前瞻性研究。
要点
- CT影像组学预测肺癌STAS、腺癌模式/分级、LVI的准确度范围为0.67至0.94。
- 纳入研究的方法学质量总体为混合至差,偏倚风险高且适用性存忧。
- 许多研究因缺乏外部验证被排除,证据尚不确定。
核心结论
- 由于偏倚风险高和适用性担忧,证据尚不确定影像组学特征能否准确预测肺癌侵袭性组织病理学特征。
研究设计与样本
- 系统综述,检索Medline、Embase、Web of Science和Cochrane Library至2023年11月3日,最终纳入11项CT影像组学试验准确性研究,采用QUADAS-2工具评估方法学质量,进行叙述性数据合成。
诊断标准与关键数值
- 报告准确度范围为0.67至0.94,对应CT影像组学模型预测肺癌侵袭性组织病理学特征。
- 4/11研究探讨STAS,6/11研究腺癌侵袭性或生长模式,1/11研究LVI。
局限性
- 纳入研究的方法学质量总体为混合至差。
- 偏倚风险高且适用性存忧,证据尚不确定。
- 许多研究因缺乏外部验证被排除。
- 需要严格的前瞻性研究且具备足够外部效度,影像组学模型才能助力改善肺癌结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To examine the accuracy of CT radiomics to predict histopathological features of aggressiveness in lung cancer using a systematic review of test accuracy studies.
METHODS: Data sources searched included Medline, Embase, Web of Science, and Cochrane Library from up to 3 November 2023. Included studies reported test accuracy of CT radiomics models to detect the presence of: spread through air spaces (STAS), predominant adenocarcinoma pattern, adenocarcinoma grade, lymphovascular invasion (LVI), tumour infiltrating lymphocytes (TIL) and tumour necrosis, in patients with lung cancer. The primary outcome was test accuracy. Two reviewers independently assessed articles for inclusion and assessed methodological quality using the QUality Assessment of Diagnostic Accuracy Studies-2 tool. A single reviewer extracted data, which was checked by a second reviewer. Narrative data synthesis was performed.
RESULTS: Eleven studies were included in the final analysis. 10/11 studies were in East Asian populations. 4/11 studies investigated STAS, 6/11 investigated adenocarcinoma invasiveness or growth pattern, and 1/11 investigated LVI. No studies investigating TIL or tumour necrosis met inclusion criteria. Studies were of generally mixed to poor methodological quality. Reported accuracies for radiomic models ranged from 0.67 to 0.94.
CONCLUSION: Due to the high risk of bias and concerns regarding applicability, the evidence is inconclusive as to whether radiomic features can accurately predict prognostically important histopathological features of cancer aggressiveness. Many studies were excluded due to lack of external validation. Rigorously conducted prospective studies with sufficient external validity will be required for radiomic models to play a role in improving lung cancer outcomes.
引用
- Cheng DO, Khaw CR, McCabe J, et al. Predicting histopathological features of aggressiveness in lung cancer using CT radiomics: a systematic review. Clin Radiol. 2024. PMID: 38853080. doi:10.1016/j.crad.2024.04.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。