健康肺人群低剂量CT支气管参数的分布研究
本研究基于荷兰一般人群前瞻性纵向生命线影像研究,纳入8869名肺健康参与者(平均年龄60.9岁±10.4,女性占54.6%),分析低剂量胸部CT自动分割获得的支气管参数分布及其与性别、年龄、身高、体重、吸烟状态的关系。结果显示男性、年龄增长与管腔更宽、管壁更厚相关,年龄、性别、身高、体重和吸烟史最多解释46%的支气管参数变异。
要点
- 健康人群中男性支气管参数(Pi10、LA、WT)均高于女性(所有P<.001)。
- 年龄增长与Pi10、LA、WT升高相关(所有P<.001)。
- Pi10在从不吸烟者最低,其次为既往吸烟者和当前吸烟者(3.62 mm±0.13、3.68 mm±0.14、3.70 mm±0.14,所有P<.001)。
核心结论
- 在健康个体中,支气管参数随性别、身高、体重和吸烟史不同而异;男性性别和年龄增长与管腔更宽和管壁更厚相关。
研究设计与样本
- 前瞻性研究,纳入2017年5月至2022年10月期间完成生命线影像研究第二轮评估的参与者,年龄至少45岁,排除肺功能异常、自报呼吸系统疾病或CT显示肺部疾病征象者,共8869名肺健康参与者(平均年龄60.9岁±10.4,女性4841名占54.6%),采用低剂量胸部CT自动分割气道管腔和管壁。
诊断标准与关键数值
- 计算内周长10 mm的假想气道支气管壁面积的平方根(Pi10)、管腔面积(LA)、管壁厚度(WT)和管壁面积百分比;男性Pi10斜率β范围3.49-3.66 mm、LA β范围25.40-29.76 mm2、WT β范围0.98-1.03 mm(所有P<.001);年龄增长与Pi10、LA、WT相关系数r2范围分别为0.06-0.09、0.02-0.01和0.02-0.07(所有P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background CT-derived bronchial parameters have been linked to chronic obstructive pulmonary disease and asthma severity, but little is known about these parameters in healthy individuals. Purpose To investigate the distribution of bronchial parameters at low-dose CT in individuals with healthy lungs from a Dutch general population. Materials and Methods In this prospective study, low-dose chest CT performed between May 2017 and October 2022 were obtained from participants who had completed the second-round assessment of the prospective, longitudinal Imaging in Lifelines study. Participants were aged at least 45 years, and those with abnormal spirometry, self-reported respiratory disease, or signs of lung disease at CT were excluded. Airway lumens and walls were segmented automatically. The square root of the bronchial wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10), luminal area (LA), wall thickness (WT), and wall area percentage were calculated. Associations between sex, age, height, weight, smoking status, and bronchial parameters were assessed using univariable and multivariable analyses. Results The study sample was composed of 8869 participants with healthy lungs (mean age, 60.9 years ± 10.4 [SD]; 4841 [54.6%] female participants), including 3672 (41.4%) never-smokers and 1197 (13.5%) individuals who currently smoke. Bronchial parameters for male participants were higher than those for female participants (Pi10, slope [β] range = 3.49-3.66 mm; LA, β range = 25.40-29.76 mm2; WT, β range = 0.98-1.03 mm; all P < .001). Increasing age correlated with higher Pi10, LA, and WT (r2 range = 0.06-0.09, 0.02-0.01, and 0.02-0.07, respectively; all P < .001). Never-smoking individuals had the lowest Pi10 followed by formerly smoking and currently smoking individuals (3.62 mm ± 0.13, 3.68 mm ± 0.14, and 3.70 mm ± 0.14, respectively; all P < .001). In multivariable regression models, age, sex, height, weight, and smoking history explained up to 46% of the variation in bronchial parameters. Conclusion In healthy individuals, bronchial parameters differed by sex, height, weight, and smoking history; male sex and increasing age were associated with wider lumens and thicker walls. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Emrich and Varga-Szemes in this issue.
引用
- Dudurych I, Pelgrim GJ, Sidorenkov G, et al. Low-Dose CT-derived Bronchial Parameters in Individuals with Healthy Lungs. Radiology. 2024. PMID: 38916504. doi:10.1148/radiol.232677
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。