超分辨率深度学习重建用于三维脑部磁共振成像:改善颅神经显示及神经血管冲突评估的观察者间一致性

Super-resolution Deep Learning Reconstruction for 3D Brain MR Imaging: Improvement of Cranial Nerve Depiction and Interobserver Agreement in Evaluations of Neurovascular Conflict.
PubMed 文献 · Acad Radiol · 2024-06-18

这项回顾性研究对37例患者的三维快速非对称自旋回波脑部磁共振图像分别采用超分辨率深度学习重建(SR-DLR)与深度学习重建(DLR)进行重建,由三名盲法阅片者评估神经血管冲突程度、结构显示、锐利度、噪声及诊断可接受性。结果显示SR-DLR在锐利度、颅神经(尤其面神经和听神经)及骨螺旋板显示、诊断可接受性方面显著优于DLR(p<0.001或p≤0.002),但主观图像噪声增加(p≥0.008);面神经神经血管冲突的观察者间一致性SR-DLR为0.429-0.923,DLR为0.175-0.689。

要点

  • SR-DLR在锐利度、面神经和听神经及骨螺旋板显示、诊断可接受性上显著优于DLR(p<0.001或p≤0.002)。
  • 面神经神经血管冲突的观察者间一致性SR-DLR为0.429-0.923,DLR为0.175-0.689。
  • SR-DLR的主观图像噪声较DLR增加(p≥0.008)。

核心结论

  • SR-DLR可提升图像锐利度,从而改善颅神经显示,并倾向于提高面神经神经血管冲突评估的观察者间一致性。

研究设计与样本

  • 回顾性研究,纳入37例患者的三维快速非对称自旋回波脑部磁共振图像,分别用SR-DLR和DLR重建;三名盲法阅片者进行定性分析,定量分析测量基底动脉中心线性感兴趣区信号强度轮廓的边缘上升距离、边缘上升斜率和半高全宽。

关键影像表现/征象

  • SR-DLR在颅神经显示方面显著优于DLR,尤其面神经、听神经及骨螺旋板(p<0.001)。
  • SR-DLR的主观图像噪声较DLR增加(p≥0.008)。
  • SR-DLR的锐利度显著优于DLR(p<0.001)。

诊断标准与关键数值

  • 面神经神经血管冲突的观察者间一致性:SR-DLR为0.429-0.923,DLR为0.175-0.689。
  • 半高全宽(mm):SR-DLR为3.1-4.3,DLR为3.3-4.8。
  • 边缘上升距离(mm):SR-DLR为0.9-1.1,DLR为1.4-2.1。
  • 边缘上升斜率(mm-1):SR-DLR为8795.5-10703.5,DLR为5157.9-7705.8。

临床应用与阅片要点

  • SR-DLR可改善颅神经(尤其面神经和听神经)及骨螺旋板的显示,有助于神经血管冲突评估。
  • 使用SR-DLR时需注意主观图像噪声较DLR增加(p≥0.008)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To determine if super-resolution deep learning reconstruction (SR-DLR) improves the depiction of cranial nerves and interobserver agreement when assessing neurovascular conflict in 3D fast asymmetric spin echo (3D FASE) brain MR images, as compared to deep learning reconstruction (DLR).

MATERIALS AND METHODS: This retrospective study involved reconstructing 3D FASE MR images of the brain for 37 patients using SR-DLR and DLR. Three blinded readers conducted qualitative image analyses, evaluating the degree of neurovascular conflict, structure depiction, sharpness, noise, and diagnostic acceptability. Quantitative analyses included measuring edge rise distance (ERD), edge rise slope (ERS), and full width at half maximum (FWHM) using the signal intensity profile along a linear region of interest across the center of the basilar artery.

RESULTS: Interobserver agreement on the degree of neurovascular conflict of the facial nerve was generally higher with SR-DLR (0.429-0.923) compared to DLR (0.175-0.689). SR-DLR exhibited increased subjective image noise compared to DLR (p ≥ 0.008). However, all three readers found SR-DLR significantly superior in terms of sharpness (p < 0.001); cranial nerve depiction, particularly of facial and acoustic nerves, as well as the osseous spiral lamina (p < 0.001); and diagnostic acceptability (p ≤ 0.002). The FWHM (mm)/ERD (mm)/ERS (mm-1) for SR-DLR and DLR was 3.1-4.3/0.9-1.1/8795.5-10,703.5 and 3.3-4.8/1.4-2.1/5157.9-7705.8, respectively, with SR-DLR's image sharpness being significantly superior (p ≤ 0.001).

CONCLUSION: SR-DLR enhances image sharpness, leading to improved cranial nerve depiction and a tendency for greater interobserver agreement regarding facial nerve neurovascular conflict.

来源:Acad Radiol,查看原文。版权归原作者所有。