全脑增强3D TSE T1WI与眼眶增强2D冠状位T1WI在3T MRI上检测急性视力丧失患者视神经强化的比较

Comparison of a Whole-Brain Contrast-Enhanced 3D TSE T1WI versus Orbits Contrast-Enhanced 2D Coronal T1WI at 3T MRI for the Detection of Optic Nerve Enhancement in Patients with Acute Loss of Visual Acuity.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-07-08

该回顾性单中心研究纳入1023例急性视力丧失患者,比较全脑增强3D TSE T1WI与眼眶增强2D冠状位T1WI检测视神经强化。两种序列检测视神经强化的一致性很强(κ=0.87),3D T1WI检测管内段强化和视盘强化的比例更高,严重伪影更少,但冠状位T1WI的阅片者信心更高。

要点

  • 全脑增强3D TSE T1WI与眼眶增强2D冠状位T1WI检测视神经强化的一致性很强(κ=0.87)。
  • 3D T1WI检测管内段强化比例高于2D T1WI(17.4% vs 13.5%,P<.001)。
  • 3D T1WI严重伪影更少(6.6% vs 9.8%),但2D T1WI阅片者信心更高(5 vs 3,P<.001)。

核心结论

  • 全脑增强3D T1WI与眼眶增强2D冠状位T1WI检测急性视力丧失患者视神经强化的一致性很强,3D T1WI诊断视神经炎的敏感度和特异度更高,尤其在管内段受累时。

研究设计与样本

  • 经机构审查委员会批准的回顾性单中心研究,纳入2014年11月至2020年2月接受3T MR成像的急性视力丧失患者1023例(女638例,男385例;平均年龄42岁,SD 18.3岁)。

诊断标准与关键数值

  • 两种序列检测视神经强化的一致性κ=0.87(95%CI 0.84-0.90)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: MR imaging is the technique of choice for patients presenting with acute loss of visual acuity with no obvious ophthalmologic cause. The goal of our study was to compare orbits contrast-enhanced 2D coronal T1WI with a whole-brain contrast-enhanced 3D (WBCE-3D) TSE T1WI at 3T for the detection of optic nerve enhancement.

MATERIALS AND METHODS: This institutional review board-approved retrospective single-center study included patients presenting with acute loss of vision who underwent 3T MR imaging from November 2014 to February 2020. Two radiologists, blinded to all data, individually assessed the presence of enhancement of the optic nerve on orbits contrast-enhanced 2D T1WI and WBCE-3D T1WI separately and in random order. A McNemar test and a Cohen κ method were used for comparing the 2 MR imaging sequences.

RESULTS: One thousand twenty-three patients (638 women and 385 men; mean age, 42 [SD, 18.3] years) were included. There was a strong concordance between WBCE-3D T1WI and orbits contrast-enhanced 2D T1WI when detecting enhancement of the optic nerve: κ = 0.87 (95% CI, 0.84-0.90). WBCE-3D T1WI was significantly more likely to detect canalicular enhancement compared with orbits contrast-enhanced 2D T1WI: 178/1023 (17.4%) versus 138/1023 (13.5%) (P < .001) and 108/1023 (10.6%) versus 90/1023 (8.8%) (P = .04), respectively. The WBCE-3D T1WI sequence detected 27/1023 (3%) instances of optic disc enhancement versus 0/1023 (0%) on orbits contrast-enhanced 2D T1WI. There were significantly fewer severe artifacts on WBCE-3D T1WI compared with orbits contrast-enhanced 2D T1WI: 68/1023 (6.6%) versus 101/1023 (9.8%) (P < .001). The median reader-reported confidence was significantly higher with coronal T1WI compared with 3D TSE T1WI: 5 (95% CI, 4-5) versus 3 (95% CI, 1-4; P < .001).

CONCLUSIONS: Our study showed that there was a strong concordance between WBCE-3D T1WI and orbits contrast-enhanced 2D T1WI when detecting enhancement of the optic nerve in patients with acute loss of visual acuity with no obvious ophthalmologic cause. WBCE-3D T1WI demonstrated higher sensitivity and specificity in diagnosing optic neuritis, particularly in cases involving the canalicular segments.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Prillard D, Charbonneau F, Clavel P, et al. Comparison of a Whole-Brain Contrast-Enhanced 3D TSE T1WI versus Orbits Contrast-Enhanced 2D Coronal T1WI at 3T MRI for the Detection of Optic Nerve Enhancement in Patients with Acute Loss of Visual Acuity. AJNR Am J Neuroradiol. 2024. PMID: 38902008. doi:10.3174/ajnr.A8233