基于深度学习重建的三维T1 SPACE血管壁成像在缩短扫描时间的同时提高图像质量:一项初步研究

Deep Learning-Based Reconstruction of 3D T1 SPACE Vessel Wall Imaging Provides Improved Image Quality with Reduced Scan Times: A Preliminary Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-11-07

本研究比较了临床常规与深度学习图像重建优化的T1 3D SPACE序列,在10名健康对照者的非增强序列和5例连续患者的增强后序列上进行评估。深度学习重建序列扫描时间为5分23秒,短于临床序列的7分26分钟,在多数血管节段显示更高的管壁信号和管腔可视化评分,且背景噪声更低、图像锐度更高、脑脊液信号均匀。初步结论提示该优化序列可能有助于在缩短梯度时间的同时改善血管壁可视化和整体图像质量,但需在更大队列中进一步验证。

要点

  • 深度学习重建序列扫描时间5分23秒,较临床序列7分26分钟缩短。
  • 增强前后多数血管节段管壁信号和管腔可视化评分深度学习重建更高。
  • 深度学习重建图像背景噪声更低、锐度更高、脑脊液信号均匀。

核心结论

  • 初步研究提示基于深度学习图像重建优化的颅内血管壁成像序列可能有助于实现更短的梯度时间,并改善血管壁可视化和整体图像质量;这些改进可能有助于颅内血管壁成像在临床实践中的更广泛应用,并应在更大队列中进一步验证。

研究设计与样本

  • 初步研究,比较临床常规与深度学习图像重建优化的T1 3D SPACE序列,在10名健康对照者中评估非增强序列、在5例连续患者中评估增强后序列,由4名接受过专科培训的神经放射科医生采用类Likert量表(评分范围1-4分)对11个血管节段的管壁和管腔显示进行评分。

关键影像表现/征象

  • 深度学习图像重建序列在增强前后图像上多数血管节段显示更高的管壁信号和管腔可视化评分,差异有统计学意义。
  • 深度学习图像重建序列背景噪声更低、图像锐度更高、脑脊液信号均匀。
  • 深度学习图像重建序列对颅内病变的显示优于或与临床序列相似。

诊断标准与关键数值

  • 采用类Likert量表评分,范围1-4分,分别对11个血管节段的管壁和管腔显示进行评分。
  • 临床序列与深度学习图像重建序列扫描时间分别为7分26分钟和5分23分钟。
  • 节段评分比较采用配对样本t检验。

临床应用与阅片要点

  • 深度学习图像重建优化的T1 3D SPACE序列可在缩短扫描时间的同时改善血管壁可视化和整体图像质量,可能有助于颅内血管壁成像的临床推广。
  • 作者指出这些改进应在更大队列中进一步验证。

局限性

  • 原文为初步研究,样本量小(10名健康对照者和5例连续患者)。
  • 作者指出这些改进应在更大队列中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Intracranial vessel wall imaging is technically challenging to implement, given the simultaneous requirements of high spatial resolution, excellent blood and CSF signal suppression, and clinically acceptable gradient times. Herein, we present our preliminary findings on the evaluation of a deep learning-optimized sequence using T1-weighted imaging.

MATERIALS AND METHODS: Clinical and optimized deep learning-based image reconstruction T1 3D Sampling Perfection with Application optimized Contrast using different flip angle Evolution (SPACE) were evaluated, comparing noncontrast sequences in 10 healthy controls and postcontrast sequences in 5 consecutive patients. Images were reviewed on a Likert-like scale by 4 fellowship-trained neuroradiologists. Scores (range, 1-4) were separately assigned for 11 vessel segments in terms of vessel wall and lumen delineation. Additionally, images were evaluated in terms of overall background noise, image sharpness, and homogeneous CSF signal. Segment-wise scores were compared using paired samples t tests.

RESULTS: The scan time for the clinical and deep learning-based image reconstruction sequences were 7:26 minutes and 5:23 minutes respectively. Deep learning-based image reconstruction images showed consistently higher wall signal and lumen visualization scores, with the differences being statistically significant in most vessel segments on both pre- and postcontrast images. Deep learning-based image reconstruction had lower background noise, higher image sharpness, and uniform CSF signal. Depiction of intracranial pathologies was better or similar on the deep learning-based image reconstruction.

CONCLUSIONS: Our preliminary findings suggest that deep learning-based image reconstruction-optimized intracranial vessel wall imaging sequences may be helpful in achieving shorter gradient times with improved vessel wall visualization and overall image quality. These improvements may help with wider adoption of intracranial vessel wall imaging in clinical practice and should be further validated on a larger cohort.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Bathla G, Messina SA, Black DF, et al. Deep Learning-Based Reconstruction of 3D T1 SPACE Vessel Wall Imaging Provides Improved Image Quality with Reduced Scan Times: A Preliminary Study. AJNR Am J Neuroradiol. 2024. PMID: 38889969. doi:10.3174/ajnr.A8382

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。