文献速递神经介入DSACT

Neuroform Atlas支架与LVIS Jr支架治疗载瘤动脉直径<2 mm的未破裂颅内动脉瘤的多中心经验

Use of the Neuroform Atlas Stent or LVIS Jr Stent for Treatment of Unruptured Intracranial Aneurysms in Parent Arteries of <2 mm in Diameter: A Multicenter Experience.
PubMed 文献 · AJNR Am J Neuroradiol · 2024-07-08

回顾性分析135例载瘤动脉直径<2 mm的未破裂颅内动脉瘤患者,分别使用Neuroform Atlas支架(66例)或LVIS Jr支架(69例)辅助弹簧圈栓塞。HR-CBCT显示LVIS Jr支架在瘤颈处贴壁不良多于Neuroform Atlas支架(11例 vs 1例,P<.05)。多因素回归显示支架角度≥75°(OR 23.963)和载瘤动脉直径不匹配比≥1.25(OR 8.043)是不完全贴壁的危险因素。

要点

  • 载瘤动脉<2 mm的未破裂动脉瘤,两种支架辅助栓塞均有效。
  • LVIS Jr支架在瘤颈处贴壁不良多于Neuroform Atlas支架(11例 vs 1例,P<.05)。
  • 支架角度≥75°或载瘤动脉直径不匹配比≥1.25是不完全贴壁危险因素。

核心结论

  • Neuroform Atlas支架和LVIS Jr支架治疗载瘤动脉直径<2 mm的未破裂颅内动脉瘤均有效,但LVIS Jr支架在部分动脉瘤瘤颈处的贴壁劣于Neuroform Atlas支架。

研究设计与样本

  • 回顾性分析2022年3月至2023年4月135例(135个动脉瘤)载瘤动脉直径<2 mm的未破裂颅内动脉瘤患者,采用Neuroform Atlas支架(66例)或LVIS Jr支架(69例)辅助弹簧圈栓塞,以HR-CBCT评估支架贴壁,2D DSA及改良Raymond-Roy分级评估即刻栓塞程度和6个月随访闭塞情况。

关键影像表现/征象

  • 术中HR-CBCT显示1枚Neuroform Atlas支架和11枚LVIS Jr支架在动脉瘤瘤颈处不完全贴壁(P<.05)。
  • DSA随访显示LVIS Jr组有3例动脉瘤复发。
  • 围手术期并发症3例(2.22%),包括2例神经系统并发症(1例远端颅内血管栓塞和1例脑实质出血)和1例术后严重消化道出血。

诊断标准与关键数值

  • 支架贴壁以术中HR-CBCT评估,不完全贴壁定义为支架在动脉瘤瘤颈处未完全贴壁。
  • 即刻栓塞程度和6个月随访闭塞以2D DSA和改良Raymond-Roy分级评估。
  • 多因素回归显示支架角度≥75°(OR 23.963;P = .005)和载瘤动脉直径不匹配比≥1.25(OR 8.043;P = .037)是不完全贴壁的危险因素,尤其对LVIS Jr支架(OR 20.297;P = .015)。

临床应用与阅片要点

  • 对于载瘤动脉直径<2 mm的未破裂颅内动脉瘤,可考虑使用Neuroform Atlas支架或LVIS Jr支架辅助弹簧圈栓塞。
  • 使用LVIS Jr支架时,若支架角度≥75°或载瘤动脉直径不匹配比≥1.25,需注意不完全贴壁的风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The Neuroform Atlas stent and the LVIS Jr stent are intracranial microstent systems for the treatment of wide-neck intracranial aneurysms. Hence, this study aimed to compare the efficacy and safety of the Neuroform Atlas stent and the LVIS Jr stent for the treatment of unruptured intracranial aneurysms in parent arteries of <2 mm in diameter.

MATERIALS AND METHODS: From March 2022 to April 2023, the clinical and imaging data of 135 patients with unruptured intracranial aneurysms treated with stent-assisted coiling using the Neuroform Atlas or LVIS Jr stent in parent arteries of <2 mm in diameter were retrospectively analyzed. Stent apposition was evaluated by high-resolution conebeam CT (HR-CBCT). Immediate aneurysm-embolization attenuation and occlusion at 6-month follow-up were evaluated using 2D DSA and the modified Raymond-Roy classification. Adverse events were recorded. Multivariate logistic regression analysis was undertaken to determine the independent factors affecting incomplete stent apposition.

RESULTS: One hundred thirty-five patients (135 aneurysms) underwent stent-assisted coiling (66 Neuroform Atlas stents and 69 LVIS Jr stents). Intraoperative HR-CBCT showed that 1 Neuroform Atlas stent and 11 LVIS Jr stents had incomplete stent apposition at the aneurysm neck (P < .05). Perioperative complications occurred in 3 cases (2.22%). These comprised 2 cases of neurologic complications (1 case of distal intracranial vascular embolism and 1 case of cerebral parenchymal hemorrhage) and 1 case of severe postprocedural gastrointestinal hemorrhage. DSA follow-up showed 3 cases of aneurysm recurrence in the LVIS Jr group. Multivariate regression analysis showed that a stent angle of ≥75° (OR, 23.963; P = .005) or a parent artery diameter mismatch ratio of ≥1.25 (OR, 8.043; P = .037) were risk factors for incomplete stent apposition, especially for the LVIS Jr stent (OR, 20.297; P = .015).

CONCLUSIONS: The Neuroform Atlas stent and LVIS Jr stent are efficacious in the treatment of unruptured intracranial aneurysms in parent arteries of <2 mm in diameter. Apposition of the LVIS Jr stent was worse than in the Neuroform Atlas stent at the neck of some aneurysms.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Li T, Shi S, Chen Q, et al. Use of the Neuroform Atlas Stent or LVIS Jr Stent for Treatment of Unruptured Intracranial Aneurysms in Parent Arteries of <2 mm in Diameter: A Multicenter Experience. AJNR Am J Neuroradiol. 2024. PMID: 38871372. doi:10.3174/ajnr.A8238

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。