文献速递腹部CT

基于人工智能的小肠克罗恩病严重程度局部评估与评分

Local Assessment and Small Bowel Crohn's Disease Severity Scoring using AI.
PubMed 文献 · Acad Radiol · 2024-05-03

研究纳入236例CT小肠造影(CTE)扫描,由两名放射科医生提出严重程度评分并在回肠远端和末端沿曲面重建每7.5 mm间隔评估。开发结合深度学习、3-D CNN和随机森林的混合模型对每个小段分类,在20%留出测试集上精确率和敏感度为42.4%–84.1%,Cohen‘s κ=0.83、准确率70.7%,与经验丰富放射科医生间的一致性(κ=0.87、准确率76.3%)相当。

要点

  • 混合模型在测试集上对正常、轻度、中度、重度各分级分类的精确率和敏感度为42.4%–84.1%。
  • 模型Cohen’s κ=0.83、准确率70.7%,与放射科医生间一致性(κ=0.87、准确率76.3%)相当。
  • 模型预测病变长度与放射科医生报告长度相关(r=0.83),识别中重度病变累及回肠比例准确率91.51%。

核心结论

  • 所提出的自动化混合模型可对小肠克罗恩病严重程度进行标准化、可重复的定量局部评估,并展示了其在克罗恩病严重程度评估中的价值。

研究设计与样本

  • 采用236例CTE扫描,由两名放射科医生提出严重程度评分并在回肠远端和末端沿曲面重建每7.5 mm间隔评估疾病严重程度。

诊断标准与关键数值

  • 混合模型在20%留出测试集上对正常、轻度、中度、重度各严重程度分类的精确率和敏感度为42.4%–84.1%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: We present a machine learning and computer vision approach for a localized, automated, and standardized scoring of Crohn's disease (CD) severity in the small bowel, overcoming the current limitations of manual measurements CT enterography (CTE) imaging and qualitative assessments, while also considering the complex anatomy and distribution of the disease.

MATERIALS AND METHODS: Two radiologists introduced a severity score and evaluated disease severity at 7.5 mm intervals along the curved planar reconstruction of the distal and terminal ileum using 236 CTE scans. A hybrid model, combining deep-learning, 3-D CNN, and Random Forest model, was developed to classify disease severity at each mini-segment. Precision, sensitivity, weighted Cohen's score, and accuracy were evaluated on a 20% hold-out test set.

RESULTS: The hybrid model achieved precision and sensitivity ranging from 42.4% to 84.1% for various severity categories (normal, mild, moderate, and severe) on the test set. The model's Cohen's score (κ = 0.83) and accuracy (70.7%) were comparable to the inter-observer agreement between experienced radiologists (κ = 0.87, accuracy = 76.3%). The model accurately predicted disease length, correlated with radiologist-reported disease length (r = 0.83), and accurately identified the portion of total ileum containing moderate-to-severe disease with an accuracy of 91.51%.

CONCLUSION: The proposed automated hybrid model offers a standardized, reproducible, and quantitative local assessment of small bowel CD severity and demonstrates its value in CD severity assessment.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Enchakalody BE, Wasnik AP, Al-Hawary MM, et al. Local Assessment and Small Bowel Crohn's Disease Severity Scoring using AI. Acad Radiol. 2024. PMID: 38702212. doi:10.1016/j.acra.2024.03.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。