文献速递介入技术与安全US

纳米颗粒介导的组织碎化术采用双频脉冲方法

Nanoparticle-Mediated Histotripsy Using Dual-Frequency Pulsing Methods.
PubMed 文献 · Ultrasound Med Biol · 2024-05-25

本研究在含全氟己烷纳米锥簇的琼脂糖体模中,用500 kHz与3 MHz双频阵列换能器以1:1压力比施加双频组织碎化脉冲,高速光学成像显示可产生可预测的清晰气泡云,空化阈值降低程度与单频脉冲相似;红细胞实验显示双频纳米颗粒介导的组织碎化术在所有体模中均于<1500个脉冲内实现完全消融,较既往单频研究约需4000个脉冲显著提高消融效率。

要点

  • 双频(500 kHz与3 MHz,1:1压力比)脉冲可在琼脂糖体模中产生小而密的气泡云。
  • 双频脉冲的空化阈值降低程度与单频脉冲相似。
  • 双频纳米颗粒介导的组织碎化术在<1500个脉冲内实现完全消融,较单频约4000个脉冲提高效率。

核心结论

  • 本研究提示双频组织碎化方法可能用于提高纳米颗粒介导的组织碎化术的消融效能。

研究设计与样本

  • 体外研究,在含全氟己烷填充纳米锥簇的琼脂糖组织体模中进行,使用模块化500 kHz与3 MHz双频阵列换能器以1:1压力比施加双频组织碎化脉冲,采用高速光学成像分析气泡云特征并测量消融效率。

关键影像表现/征象

  • 光学成像显示所有测试病例均产生可预测、边界清晰的气泡云。
  • 双频脉冲在琼脂糖体模中成核出小而密的气泡云,其大小介于各组成频率之间,但面积更接近较高组成频率。

诊断标准与关键数值

  • 双频纳米颗粒介导的组织碎化术在红细胞实验中于所有体模中均于<1500个脉冲内实现完全消融。
  • 既往单频纳米颗粒介导的组织碎化术研究约需4000个脉冲实现完全消融。

临床应用与阅片要点

  • 作者认为双频组织碎化方法可能提高纳米颗粒介导的组织碎化术的消融效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Nanoparticle-mediated histotripsy (NMH) is a novel ablation method that combines nanoparticles as artificial cavitation nuclei with focused ultrasound pulsing to achieve targeted, non-invasive, and cell-selective tumor ablation. The study described here examined the effect of dual-frequency histotripsy pulsing on the cavitation threshold, bubble cloud characteristics, and ablative efficiency in NMH. High-speed optical imaging was used to analyze bubble cloud characteristics and to measure ablation efficiency for NMH inside agarose tissue phantoms containing perfluorohexane-filled nanocone clusters, which were previously developed to reduce the histotripsy cavitation threshold for NMH.

METHODS: Dual-frequency histotripsy pulsing was applied at a 1:1 pressure ratio using a modular 500 kHz and 3 MHz dual-frequency array transducer. Optical imaging results revealed predictable, well-defined bubble clouds generated for all tested cases with similar reductions in the cavitation thresholds observed for single-frequency and dual-frequency pulsing.

RESULTS: Dual-frequency pulsing was seen to nucleate small, dense clouds in agarose phantoms, intermediate in size of their component frequencies but closer in area to that of the higher component frequency. Red blood cell experiments revealed complete ablations were generated by dual-frequency NMH in all phantoms in <1500 pulses. This result was a significant increase in ablation efficiency compared with the ∼4000 pulses required in prior single-frequency NMH studies.

CONCLUSION: Overall, this study indicates the potential for using dual-frequency histotripsy methods to increase the ablation efficacy of NMH.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Edsall C, Huynh L, Mustafa W, et al. Nanoparticle-Mediated Histotripsy Using Dual-Frequency Pulsing Methods. Ultrasound Med Biol. 2024. PMID: 38797630. doi:10.1016/j.ultrasmedbio.2024.04.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。