文献速递儿科影像骨肌DR

镇静对疑似虐待儿童初始骨骼调查质量的影响:一项两中心比较审计

The impact of sedation on the quality of initial skeletal surveys performed for suspected physical abuse in children: a comparative two-centre audit.
PubMed 文献 · Clin Radiol · 2024-04-24

该两中心审计比较了镇静与不镇静下疑似虐待儿童初始骨骼调查的质量,共100例<2岁患儿、4055次投照。镇静组重复投照总数及<12月龄重复数更少,但检查时间显著更长;重复投照的有效剂量无显著差异。作者认为若主要考虑降低辐射剂量和检查时间,不支持常规使用镇静。

要点

  • 镇静组重复投照总数及<12月龄重复数显著少于不镇静组。
  • 不镇静组平均检查时间显著更短,排除离群值后仍显著。
  • 重复投照的有效剂量两组无显著差异。

核心结论

  • 镇静组重复投照更少(尤其<12月龄),但检查时间显著更长;重复投照有效剂量无差异;若主要考虑降低辐射剂量和检查时间,不支持常规镇静。

研究设计与样本

  • 两中心比较审计,回顾性纳入两家三级儿童医院连续100例<2岁疑似虐待儿童的生前初始骨骼调查;中心1不镇静,中心2常规镇静。

关键影像表现/征象

  • 共完成4055次投照,其中93次(2.3%)为重复投照。
  • 重复投照总数两组差异显著(P=0.001),<12月龄重复数差异显著(P=0.008)。
  • 不镇静组平均检查时间显著更短(P=0.005),排除离群值后仍显著(P=0.002)。

诊断标准与关键数值

  • 常规投照数(P=0.587)、成像不完整部位(P=0.254)、旋转/体位欠佳(P=0.527)两组无显著差异。
  • >12月龄重复数(P=0.089)、<12月龄常规投照数(P=0.642)、>12月龄常规投照数(P=0.979)两组无显著差异。
  • 重复投照的有效剂量两组无显著差异(P=0.286)。

临床应用与阅片要点

  • 作者认为若主要考虑降低辐射剂量和检查时间,不支持常规使用镇静。
  • 镇静可减少重复投照,尤其<12月龄患儿,但需权衡检查时间延长。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The impact of sedation on the quality of initial skeletal surveys performed for suspected physical abuse in children is not known.

OBJECTIVE: To assess whether sedation influenced the number of, reason for and effective dose of repeat radiographs obtained as part of initial skeletal surveys, and their mean examination times.

MATERIALS AND METHODS: One hundred consecutive antemortem initial skeletal survey examinations performed for suspected physical abuse in children <2 years were retrieved from two tertiary paediatric hospitals: Centre 1, where sedation is not used for initial skeletal survey imaging; and Centre 2, where sedation is used routinely.

RESULTS: In total, 4055 radiographic projections were performed, of which 93 (2.3%) were repeats. Comparing centres, there was a significant difference in the total number of repeats (P=0.001) and the number of repeats in children aged <12 months (P=0.008). Mean examination times were significantly shorter in unsedated children (P=0.005), even after outliers were excluded (P=0.002). There was no significant difference between the number of routine projections (P=0.587), incompletely imaged body parts (P=0.254), rotation/suboptimal positioning (P=0.527), repeats in children aged >12 months (P=0.089), routine projections in children aged <12 months (P=0.642) or >12 months (P=0.979) or the effective doses of repeats (P=0.286).

CONCLUSION: There were fewer repeat projections in sedated children and those aged <12 months but examination times were significantly longer. There was no difference in the effective doses of repeated projections. The routine use of sedation is not supported when performing skeletal survey imaging if the primary considerations are reducing radiation dose and examination time.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Paddock M, Johnson PC, Staley A, et al. The impact of sedation on the quality of initial skeletal surveys performed for suspected physical abuse in children: a comparative two-centre audit. Clin Radiol. 2024. PMID: 38772767. doi:10.1016/j.crad.2024.04.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。