文献速递外周血管技术与安全US

实时剪切波弹性成像与超快脉搏波速度评估代谢综合征患者颈动脉僵硬度

Evaluation of Carotid Stiffness in Metabolic Syndrome by Real-Time Shear Wave Elasticity Imaging and Ultrafast Pulse Wave Velocity.
PubMed 文献 · Ultrasound Med Biol · 2024-05-27

本研究纳入181例代谢综合征患者(按颈动脉内膜中层厚度及斑块分为MS I、MS II、MS III三组)与73例健康对照,采用实时剪切波弹性成像和超快脉搏波速度评估颈动脉僵硬度。结果显示PWV-BS、PWV-ES与动脉硬化严重程度显著相关,MS III和MS II组PWV-ES值高于MS I组和对照组,MS III组颈动脉前壁和后壁弹性模量Mean、Max、Min值均超过其他组。作者认为这两种无创、安全、可重复的影像技术可定量评估颈总动脉壁僵硬度,为心血管风险评估提供重要信息。

要点

  • PWV-ES在四组间差异有统计学意义(p < 0.05),MS III和MS II组PWV-ES值高于MS I组和对照组。
  • MS III组颈动脉前壁和后壁弹性模量Mean、Max、Min值均超过其他组。
  • PWV-BS、PWV-ES与动脉硬化严重程度显著相关,随动脉硬化进展重要性增加。

核心结论

  • 实时剪切波弹性成像和超快脉搏波速度是评估代谢综合征患者动脉粥样硬化风险的有价值工具,可无创、安全、可重复地定量评估颈总动脉壁僵硬度,为心血管风险评估提供重要信息。

研究设计与样本

  • 研究纳入181例代谢综合征患者(MS组)与73例健康成人(NC组)进行比较;MS组分为MS I组(CIMT正常,CIMT < 1.0 mm,无斑块,n = 61)、MS II组(CIMT增厚,1.0 mm ≤ CIMT < 1.5 mm,无斑块,n = 39)、MS III组(斑块组,CIMT ≥ 1.5 mm,有斑块,n = 81);评估参数包括CIMT、颈动脉前壁和后壁弹性模量值(Mean、Max、Min)、收缩期开始脉搏波速度(PWV-BS)和收缩期结束脉搏波速度(PWV-ES)。

关键影像表现/征象

  • MS III组颈动脉前壁和后壁弹性模量Mean、Max、Min值均超过其他组。
  • MS III和MS II组PWV-ES值高于MS I组和对照组。
  • MS III、MS II和MS I组分别与对照组比较差异有统计学意义(p < 0.05)。

诊断标准与关键数值

  • MS I组:CIMT < 1.0 mm,无斑块(n = 61)。
  • MS II组:1.0 mm ≤ CIMT < 1.5 mm,无斑块(n = 39)。
  • MS III组:CIMT ≥ 1.5 mm,有斑块(n = 81)。
  • PWV-ES在四组间差异有统计学意义(p < 0.05)。

临床应用与阅片要点

  • 实时剪切波弹性成像和超快脉搏波速度可定量评估颈总动脉壁僵硬度,用于代谢综合征患者动脉粥样硬化风险评估。
  • PWV-ES在代谢综合征伴颈动脉内膜中层厚度增厚或斑块的患者中升高,可作为评估动脉硬化严重程度的参考指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study utilized real-time shear wave elasticity imaging (SWE) and ultrafast pulse wave velocity (ufPWV) to assess carotid arterial stiffness, aiming to predict atherosclerosis risk in patients with metabolic syndrome (MS).

METHODS: In this study, 181 patients with metabolic syndrome (MS group) were compared with 73 healthy adults. The MS group was divided into three groups: MS I group: CIMT was normal (CIMT < 1.0 mm, no plaque, n = 61); MS II group: CIMT thickening (1.0 mm ≤ CIMT<1.5 mm, no plaque, n = 39); MS III group: plaque group (CIMT ≥ 1.5 mm, plaque, n = 81). Concurrently, the group of 73 healthy individuals was designated as the control set (NC). Parameters assessed include carotid intima-media thickness (CIMT), elastic modulus values of the carotid artery's anterior and posterior walls (Mean, Max, Min), pulse wave velocity at systole's commencement (PWV-BS), and pulse wave velocity at systole's termination (PWV-ES). Differences, distribution characteristics, and correlations across these groups were analyzed.

RESULTS: A significant association was found between PWV-BS, PWV-ES, and arteriosclerosis severity, with these factors gaining importance as arteriosclerosis progressed. Notably, PWV-ES differences were significant across the four groups (p < 0.05). Both MS III and MS II groups exhibited higher PWV-ES values compared to the MS I group and controls. Statistically significant differences were observed between MS III, MS II, and MS I groups relative to the control group (p < 0.05). Additionally, the Mean, Max, and Min values of the anterior and posterior carotid walls in the MS III group surpassed those of the other groups.

CONCLUSION: Real-time shear wave elasticity imaging and ultrafast pulse wave velocity are valuable tools for assessing atherosclerosis risk in MS patients. These non-invasive, safe, and reproducible imaging techniques can quantitatively evaluate the stiffness of the common carotid artery's wall, offering important insights into cardiovascular risk assessment.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Guo S, Gu C, Sun L, et al. Evaluation of Carotid Stiffness in Metabolic Syndrome by Real-Time Shear Wave Elasticity Imaging and Ultrafast Pulse Wave Velocity. Ultrasound Med Biol. 2024. PMID: 38806338. doi:10.1016/j.ultrasmedbio.2024.05.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。