一种创建应用专用超声散斑追踪算法的优化方法
本研究提出一种仅需重复测量数据的优化方法,用于为猪和人类膝关节内侧韧带结构定制超声散斑追踪算法。经1500次迭代优化后,调优算法在独立测试集上的超声应变与数字图像相关测量高度一致(猪R>0.99,RMSE<0.59%),人类动态数据集RMSE<6.28%,人膝屈曲时内侧韧带结构应变与前后位置强相关(R>0.91)。
要点
- 基于重复测量标准差的替代优化可无需金标准参考数据即定制散斑追踪算法。
- 调优算法在猪离体韧带准静态测量中与DIC表面应变高度一致(R>0.99,RMSE<0.59%)。
- 人离体膝动态载荷下,调优算法测得的韧带附着点长度变化RMSE<6.28%。
核心结论
- 基于重复性的优化流程调整超声散斑追踪算法,对膝关节内侧韧带结构可获得稳健可靠、低RMSE的结果,该工具可能同样有益于其他软组织位移或应变测量应用,并有助于开发评估软组织生物力学的新型超声诊断工具。
研究设计与样本
- 方法学研究:对三只准静态加载猪离体膝关节的内侧副韧带及一例动态加载人离体膝关节的内侧韧带结构进行超声软组织运动采集,以训练子集通过替代优化创建定制散斑追踪算法,再用独立测试子集验证。
关键影像表现/征象
- 优化经1500次迭代后,猪与人训练数据收敛至相近的重复应变图归一化标准差(猪0.19,人0.26)。
- 调优算法在猪准静态测量中计算出的超声应变与DIC测量高度匹配(R>0.99,RMSE<0.59%)。
- 调优算法在人动态数据集中测得的被追踪韧带附着点间长度变化与光学追踪值匹配(RMSE<6.28%)。
- 人标本屈曲过程中内侧韧带结构的应变与韧带前后位置强相关(R>0.91)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Ultrasound speckle tracking enables in vivo measurement of soft tissue deformation or strain, providing a non-invasive diagnostic tool to quantify tissue health. However, adoption into new fields is challenging since algorithms need to be tuned with gold-standard reference data that are expensive or impractical to acquire. Here, we present a novel optimization approach that only requires repeated measurements, which can be acquired for new applications where reference data might not be readily available or difficult to get hold of.
METHODS: Soft tissue motion was captured using ultrasound for the medial collateral ligament (MCL) of three quasi-statically loaded porcine stifle joints, and medial ligamentous structures of a dynamically loaded human cadaveric knee joint. Using a training subset, custom speckle tracking algorithms were created for the porcine and human ligaments using surrogate optimization, which aimed to maximize repeatability by minimizing the normalized standard deviation of calculated strain maps for repeat measurements. An unseen test subset was then used to validate the tuned algorithms by comparing the ultrasound strains to digital image correlation (DIC) surface strains (porcine specimens) and length change values of the optically tracked ligament attachments (human specimens).
RESULTS: After 1500 iterations, the optimization routine based on the porcine and human training data converged to similar values of normalized standard deviations of repeat strain maps (porcine: 0.19, human: 0.26). Ultrasound strains calculated for the independent test sets using the tuned algorithms closely matched the DIC measurements for the porcine quasi-static measurements (R > 0.99, RMSE < 0.59%) and the length change between the tracked ligament attachments for the dynamic human dataset (RMSE < 6.28%). Furthermore, strains in the medial ligamentous structures of the human specimen during flexion showed a strong correlation with anterior/posterior position on the ligaments (R > 0.91).
CONCLUSION: Adjusting ultrasound speckle tracking algorithms using an optimization routine based on repeatability led to robust and reliable results with low RMSE for the medial ligamentous structures of the knee. This tool may be equally beneficial in other soft-tissue displacement or strain measurement applications and can assist in the development of novel ultrasonic diagnostic tools to assess soft tissue biomechanics.