儿科急诊医师、放射科医师与骨科医师对肱骨髁上骨折Gartland分型的一致性
回顾性独立采用改良Gartland分型对100例儿童肱骨髁上骨折肘关节X线片进行分型,比较两个儿科放射科医师、两个儿科骨科医师和两个儿科急诊医师之间的一致性。三个亚专科间共识分型的观察者间一致性为kappa=0.77(95%CI 0.69-0.85),在区分Gartland I型与更高分型时kappa=0.77(95%CI 0.66-0.89)。结论认为改良Gartland分型在三个专科间具有可重复性。
要点
- 改良Gartland分型在儿科急诊、放射科和骨科医师间共识分型的kappa=0.77(95%CI 0.69-0.85)。
- 区分Gartland I型与更高分型时三专科间kappa=0.77(95%CI 0.66-0.89)。
- 放射科医师分型与参考标准不一致15次,急诊医师19次,骨科医师9次。
核心结论
- 改良Gartland分型用于儿童肱骨髁上骨折在儿科急诊医师、放射科医师和骨科医师间具有可重复性。
研究设计与样本
- 回顾性研究,纳入100例儿童肱骨髁上骨折的肘关节X线片,由2名儿科放射科医师、2名儿科骨科医师和2名儿科急诊医师独立分型,同亚专科第三名医师在需要时打破平局以达成共识,读者互盲且对病历盲,以治疗骨科医师病历记录的改良Gartland分型为参考标准。
诊断标准与关键数值
- 三专科间共识骨折分型的观察者间一致性kappa=0.77(95%CI 0.69-0.85);区分Gartland I型与更高分型时三专科间kappa=0.77(95%CI 0.66-0.89)。
临床应用与阅片要点
- 改良Gartland分型是骨科医师最广泛接受的肱骨髁上骨折分级方法,与识别可能需要手术的骨折相关。
- 儿科放射科医师、儿科骨科医师和儿科急诊医师采用改良Gartland分型评估儿童肱骨髁上骨折时具有可重复性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The modified Gartland classification is the most widely accepted grading method of supracondylar humeral fractures among orthopedic surgeons and is relevant to identifying fractures that may require surgery.
OBJECTIVE: To assess the interobserver reliability of the modified Gartland classification among pediatric radiologists, pediatric orthopedic surgeons, and pediatric emergency medicine physicians.
MATERIALS AND METHODS: Elbow radiographs for 100 children with supracondylar humeral fractures were retrospectively independently graded by two pediatric radiologists, two pediatric orthopedic surgeons, and two pediatric emergency medicine physicians using the modified Gartland classification. A third grader of the same subspecialty served as a tie-breaker as needed to reach consensus. Readers were blinded to one another and to the medical record. The modified Gartland grade documented in the medical record by the treating orthopedic provider was used as the reference standard. Interobserver agreement was assessed using kappa statistics.
RESULTS: There was substantial interobserver agreement (kappa = 0.77 [95% CI, 0.69-0.85]) on consensus fracture grade between the three subspecialties. Similarly, when discriminating between Gartland type I and higher fracture grades, there was substantial interobserver agreement between specialties (kappa = 0.77 [95% CI, 0.66-0.89]). The grade assigned by pediatric radiologists differed from the reference standard on 15 occasions, pediatric emergency medicine differed on 19 occasions, and pediatric orthopedics differed on 9 occasions.
CONCLUSION: The modified Gartland classification for supracondylar humeral fractures is reproducible among pediatric emergency medicine physicians, radiologists, and orthopedic surgeons.
引用
- Schultz RJ, Amaral JZ, Bridges CS, et al. Gartland classification concordance of supracondylar fractures among pediatric emergency medicine physicians, radiologists, and orthopedic surgeons. Pediatr Radiol. 2024. PMID: 38693251. doi:10.1007/s00247-024-05935-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。