基于群体与个体动脉输入函数的超快动态增强乳腺MRI定量分析及与半定量分析的比较
前瞻性纳入99例患者109个病灶(85恶性、24良性),比较基于群体动脉输入函数(P-AIF)的在线定量分析、基于个体动脉输入函数(I-AIF)的离线定量分析与半定量分析对乳腺癌的诊断价值;P-AIF在线定量kep的AUC与I-AIF离线定量相似(0.782 vs 0.779),高于半定量washin(0.782 vs 0.630),F1分数更大(0.920 vs 0.780 vs 0.480)。
要点
- P-AIF在线定量kep诊断乳腺癌AUC为0.782,与I-AIF离线定量0.779相似。
- P-AIF在线定量kep的AUC高于半定量washin的0.630。
- P-AIF在线定量F1分数0.920,高于I-AIF离线0.780与半定量0.480。
核心结论
- CDTV超快DCE-MRI基于P-AIF的在线定量分析对乳腺病灶的鉴别诊断准确性与基于I-AIF的离线定量分析相似,且高于半定量分析。
研究设计与样本
- 前瞻性研究纳入99例连续患者共109个病灶(85个恶性、24个良性),采用CAIPIRINHA-Dixon-TWIST-VIBE(CDTV)DCE-MRI获取基于模型的参数(Ktrans、kep、ve)和无模型参数(washin、washout)。
诊断标准与关键数值
- P-AIF在线定量kep诊断乳腺癌AUC为0.782,I-AIF离线定量kep为0.779,两者比较p=0.954。
- P-AIF在线定量kep的AUC高于半定量washin的0.630,p=0.034。
- P-AIF在线定量F1分数为0.920,I-AIF离线定量为0.780,半定量分析为0.480。
- 两种定量分析方案的kep值比较p=0.944,无统计学显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the value of inline quantitative analysis of ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a population-based arterial input function (P-AIF) compared with offline quantitative analysis with an individual AIF (I-AIF) and semi-quantitative analysis for diagnosing breast cancer.
METHODS: This prospective study included 99 consecutive patients with 109 lesions (85 malignant and 24 benign). Model-based parameters (Ktrans, kep, and ve) and model-free parameters (washin and washout) were derived from CAIPIRINHA-Dixon-TWIST-VIBE (CDTV) DCE-MRI. Univariate analysis and multivariate logistic regression analysis with forward stepwise covariate selection were performed to identify significant variables. The AUC and F1 score were assessed for semi-quantitative and two quantitative analyses.
RESULTS: kep from inline quantitative analysis with P-AIF for diagnosing breast cancer provided an AUC similar to kep from offline quantitative analysis with I-AIF (0.782 vs 0.779, p = 0.954), higher compared to washin from semi-quantitative analysis (0.782 vs 0.630, p = 0.034). Furthermore, the inline quantitative analysis with P-AIF achieved the larger F1 score (0.920) compared with offline quantitative analysis with I-AIF (0.780) and semi-quantitative analysis (0.480). There were no statistically significant differences for kep values between the two quantitative analysis schemes (p = 0.944).
CONCLUSION: The inline quantitative analysis with P-AIF from CDTV in characterizing breast lesions could offer similar diagnostic accuracy to offline quantitative analysis with I-AIF, and higher diagnostic accuracy to semi-quantitative analysis.
引用
- Xie T, Zhao Q, Fu C, et al. Quantitative analysis from ultrafast dynamic contrast-enhanced breast MRI using population-based versus individual arterial input functions, and comparison with semi-quantitative analysis. Eur J Radiol. 2024. PMID: 38788607. doi:10.1016/j.ejrad.2024.111501
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。