拓展保乳手术的边界——多导丝定位(3根或以上)是否与切缘阳性风险增加及长期复发相关?
回顾性单中心研究纳入2010至2020年间232例需至少3根导丝定位的保乳手术患者(多导丝组),并与232例单导丝保乳患者(单导丝组)按时间匹配。多导丝组切缘阳性率更高(13% vs 7%,P=0.03),但导丝数量并非切缘阳性的独立预测因子;多导丝组远处转移率更高(12% vs 4%,P=0.006),局部区域无病生存两组相似(P=0.1)。
要点
- 多导丝保乳组切缘阳性率13% vs 单导丝组7%(P=0.03),但导丝数量不是切缘阳性的独立预测因子。
- 切缘阳性更常见于含导管原位癌成分(77% vs 53%,P=0.001)、含浸润性小叶癌成分(15% vs 9%,P=0.013)及ER阳性(94% vs 85%,P=0.05)者。
- 多导丝组远处转移率12% vs 单导丝组4%(P=0.006),局部区域无病生存两组相似(P=0.1)。
核心结论
- 需3根或以上导丝定位的保乳手术与略高的切缘阳性比例相关,该风险增加似乎与肿瘤类型(导管原位癌成分、浸润性小叶癌成分及ER状态)有关而非导丝数量;导丝数量对局部区域无病生存无显著影响。
研究设计与样本
- 回顾性单中心研究,多导丝组232例(2010至2020年间保乳手术需至少3根导丝定位),对照组为232例单导丝保乳患者并按时间与多导丝组匹配;纳入浸润性恶性肿瘤或导管原位癌患者,收集临床、影像及病理数据。
诊断标准与关键数值
- 多导丝组切缘阳性13% vs 单导丝组7%(P=0.03),多导丝组再行肿块切除或转为乳房切除的比例为7% vs 4%(P=0.17)。
- 全队列多变量分析中切缘阳性者含导管原位癌成分77% vs 53%(P=0.001)、含浸润性小叶癌成分15% vs 9%(P=0.013)、ER阳性94% vs 85%(P=0.05)。
- 多导丝组 vs 单导丝组:平均年龄57岁 vs 63.1岁(P<0.001),平均肿瘤大小5.1 cm vs 1.3 cm(P<0.001)。
- 多导丝组 vs 单导丝组:钼靶钙化72% vs 17%(P<0.001),阳性淋巴结75% vs 45%(P=0.019),导管原位癌成分72% vs 38%(P<0.001)。
- 多导丝组 vs 单导丝组:远处转移12% vs 4%(P=0.006),局部区域无病生存两组相似(P=0.1)。
临床应用与阅片要点
- 多导丝定位保乳术前应结合钼靶钙化范围及肿瘤大小评估切缘风险。
- 含导管原位癌成分、浸润性小叶癌成分或ER阳性的肿瘤切缘阳性风险更高,报告时应提示临床。
- 导丝数量本身不是切缘阳性的独立预测因子,多导丝组远处转移率更高(12% vs 4%,P=0.006)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: In the last two decades there has been a paradigm shift with breast conserving surgery (BCS) being applied to larger and more extensive breast malignancies. The aim of this study is to examine the success of BCS being performed in patients with extensive breast malignancies requiring at least 3 wires for localization, and to assess possible risk factors for failure.
MATERIALS AND METHODS: We performed a retrospective single center review of 232 patients who underwent BCS between 2010 and 2020 requiring at least 3 wires for localization, thus comprising the multi-wire group (MWG). The cohort included a control group of 232 single-wire BCS patients (SWG) chronologically matched with the MWG. Patients with either invasive malignancy or ductal carcinoma in situ (DCIS) were included in the study. Clinical, radiological, and pathological data was collected. Proportions of positive surgical margins, re-lumpectomies and conversion to mastectomy were calculated. Survival analysis for locoregional and distant recurrence was performed.
RESULTS: Women in the MWG were younger (mean age 57 vs. 63.1, P < 0.001), had larger tumor size (mean size 5.1 cm vs. 1.3 cm, p < 0.001), a higher prevalence of calcifications on mammograms (72 % vs. 17 %, P < 0.001), a higher proportion of positive lymph nodes (75 % vs. 45 %, P = 0.019), and an elevated incidence of a ductal carcinoma in situ (DCIS) component (72 % vs. 38 %, P < 0.001). Positive surgical margins were higher in the MWG (13 % vs 7 %, P = 0.03), which lead to higher proportions of re-lumpectomies or conversion to mastectomies (7 % vs 4 %, P = 0.17). On multivariate analysis of the entire cohort, patients with positive margins were more likely to have a DCIS component (77 % vs 53 %, P = 0.001), an infiltrating lobular carcinoma (ILC) component (15 % vs 9 %, P = 0.013), and positive ER hormonal status (94 % vs 85 %, p = 0.05). The number of wires was not an independent predictor of positive margins. On long-term analysis, the locoregional disease-free survival was similar between the SWG and MWG (P = 0.1). However, the MWG showed higher rates of distant metastasis (12 % vs 4 %, P = 0.006).
CONCLUSIONS: BCS requiring 3 or more wires is associated with a slightly higher proportion of positive margins. The increased risk of positive margins appears to be related to the type of tumor (DCIS component, ILC component and ER status) rather than to the number of wires. The number of wires does not significantly impact locoregional disease-free survival.
引用
- Golan O, Khatib M, Menes TS, et al. Pushing the envelope in breast conserving surgery - is multiple-wire localization (3 or more wires) associated with increased risk of compromised margins and long-term recurrence? Eur J Radiol. 2024. PMID: 38776805. doi:10.1016/j.ejrad.2024.111511
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。