文献速递妇产影像介入泌尿生殖MR

T2加权MR图像信号强度异质性定量分析对高强度聚焦超声治疗子宫肌瘤的预测作用

The Predictive Effect of Quantitative Analysis of Signal Intensity Heterogeneity on T2-Weighted MR Images for High-intensity Focused Ultrasound Treatment of Uterine Fibroids.
PubMed 文献 · Acad Radiol · 2024-05-03

研究采用T2WI信号强度标准差量化异质性,回顾性分析575例HIFU治疗患者,发现标准差与无灌注体积比负相关(r=-0.460,p<0.001),预测消融效果优于标化信号强度(0.767 vs. 0.701,p=0.006),并据此分为三级;另用65例外中心数据验证分级性能。

要点

  • T2WI信号强度标准差与子宫肌瘤HIFU消融的无灌注体积比呈负相关(r=-0.460,p<0.001)。
  • SD预测消融效果的效能高于标化信号强度(0.767 vs. 0.701,p=0.006)。
  • 按SD分级:SD I<101.0,SD II 101.0≤SD<138.7,SD III≥138.7;SD I的治疗时间、辐照时间、治疗强度及总能量均低于SD II和III(p<0.05)。

核心结论

  • 子宫肌瘤T2WI信号强度异质性与无灌注体积比负相关,信号强度标准差可用于预测HIFU消融难度和消融效果。

研究设计与样本

  • 回顾性分析575例接受HIFU治疗的子宫肌瘤患者,采用T2WI信号强度标准差量化异质性;另用另一中心65例作为外部验证集验证SD分级性能。

关键影像表现/征象

  • T2WI信号强度标准差与无灌注体积比呈负相关(r=-0.460,p<0.001)。
  • SD I级的治疗时间、辐照时间、治疗强度和总能量低于SD II级和SD III级(p<0.05)。

诊断标准与关键数值

  • SD预测消融效果的效能高于标化信号强度(0.767 vs. 0.701,p=0.006)。
  • 单因素和多因素logistic回归分析显示SD是消融效果的独立预测因素。
  • 按SD分为三级:SD I为SD<101.0,SD II为101.0≤SD<138.7,SD III为SD≥138.7。

临床应用与阅片要点

  • 可测量子宫肌瘤T2WI信号强度标准差以量化异质性,辅助预判HIFU消融难度和效果。
  • SD I级者治疗时间、辐照时间、治疗强度和总能量较低,SD II和III级相应较高(p<0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate whether the quantitative index of signal intensity (SI) heterogeneity on T2-weighted (T2W) magnetic resonance images can predict the difficulty and efficacy of high-intensity focused ultrasound (HIFU) ablation for uterine fibroids.

MATERIALS AND METHODS: The standard deviation (SD) of T2W image (T2WI) SI was used to quantify SI heterogeneity. The correlation between SD and the non-perfused volume ratio (NPVR) in 575 patients undergoing HIFU treatment was retrospectively analyzed, and the efficacy of SD in predicting NPVR was discussed. Three classifications were made based on the SD, and the ablation difficulty and ablation effect of different grades were compared. A total of 65 cases from another center were used as an external validation set to verify the classification performance of SD.

RESULTS: The SD of SI was negatively correlated with NPVR (r = -0.460, p < 0.001). The predictive efficiency of SD for the ablation effect was higher than that of the scaled signal intensity (0.767 vs. 0.701, p = 0.006). Univariate and multivariate logistic regression analyses showed that SD was an independent predictor of ablation effect. Based on SD, the three classifications were divided into SD I: SD < 101.0, SD II: 101.0 ≤ SD < 138.7, and SD III: SD≥ 138.7. The treatment time, sonication time, treatment intensity, and total energy of SD I were lower than those of SD II and III (p < 0.05).

CONCLUSION: The heterogeneity of T2WI SI of uterine fibroids is negatively correlated with NPVR. The SD of SI can be used to predict the ablation difficulty and ablation effect of HIFU.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang L, Liu Y, Lin J, et al. The Predictive Effect of Quantitative Analysis of Signal Intensity Heterogeneity on T2-Weighted MR Images for High-intensity Focused Ultrasound Treatment of Uterine Fibroids. Acad Radiol. 2024. PMID: 38704283. doi:10.1016/j.acra.2024.04.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。