经阴道超声与磁共振成像诊断直肠阴道隔深部浸润型子宫内膜异位的诊断效能:头对头比较的Meta分析
该Meta分析纳入8篇文献共721例患者,比较经阴道超声(TVS)与磁共振成像(MRI)诊断直肠阴道隔深部浸润型子宫内膜异位(DIE)的效能。MRI汇总敏感度0.74(95%CI 0.66-0.82)高于TVS的0.51(95%CI 0.31-0.72)(P=0.04);两者特异度分别为0.93(95%CI 0.84-0.99)与0.97(95%CI 0.94-1.00),差异无统计学意义(P=0.22)。作者认为MRI敏感度更高、特异度相当,但纳入文献有限可能影响证据强度,需更大样本前瞻性研究验证。
要点
- MRI诊断直肠阴道隔DIE的汇总敏感度0.74,高于TVS的0.51(P=0.04)。
- TVS与MRI汇总特异度分别为0.97与0.93,两者差异无统计学意义(P=0.22)。
- 纳入文献仅8篇、共721例,作者认为可能影响证据强度,需进一步研究验证。
核心结论
- 在直肠阴道隔深部浸润型子宫内膜异位患者中,MRI敏感度高于TVS,特异度与TVS相当。
- 作者指出纳入文献数量有限可能影响结果证据强度,需更大样本前瞻性研究验证。
研究设计与样本
- 研究类型为头对头比较的诊断准确性Meta分析。
- 检索PubMed与Embase数据库,检索截止至2023年11月。
- 纳入评估TVS与MRI诊断直肠阴道隔受累DIE诊断效能的研究。
- 共纳入8篇文献、721例患者。
- 采用DerSimonian-Laird法结合Freeman-Tukey双反正弦变换进行敏感度与特异度分析,并以QUADAS-2工具评价研究质量。
诊断标准与关键数值
- TVS诊断直肠阴道隔DIE的汇总敏感度为0.51(95%CI 0.31-0.72),汇总特异度为0.97(95%CI 0.94-1.00)。
- MRI诊断直肠阴道隔DIE的汇总敏感度为0.74(95%CI 0.66-0.82),汇总特异度为0.93(95%CI 0.84-0.99)。
- MRI与TVS敏感度比较P=0.04,特异度比较P=0.22。
临床应用与阅片要点
- 作者结论认为MRI在直肠阴道隔DIE中敏感度高于TVS、特异度与TVS相当。
- 作者指出纳入文献有限可能影响证据强度,需更大样本前瞻性研究验证。
局限性
- 作者指出纳入文献数量有限可能影响结果证据强度。
- 作者指出需更大样本量和前瞻性设计的研究验证这些发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: We aimed to compare the diagnostic performance of transvaginal sonography (TVS) versus magnetic resonance imaging (MRI) in identifying deep infiltrating endometriosis (DIE) in the rectovaginal septum (RVS) of affected patients.
MATERIALS AND METHODS: An extensive search was conducted in the PubMed, Embase databases to identify available publications up to November 2023. Studies evaluating the diagnostic perfor-mance of TVS and MRI for DIE in patients with rectovaginal septum involvement were all included. Sensitivity and specificity analyses employed the DerSi-monian and Laird method, complemented by the Freeman-Tukey double arc-sine trans-formation. Additionally, the study quality was rigorously evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) method.
RESULTS: The meta-analysis encompassed 8 articles with a total of 721 patients. It revealed that the overall sensitivity of TVS was 0.51 (95% CI: 0.31-0.72), contrasted with 0.74 (95% CI: 0.66-0.82) for MRI. This finding suggests a higher sensitivity of MRI compared to TVS (P=0.04). Conversely, the overall specificity was 0.97 (95%CI: 0.94-1.00) for TVS and 0.93 (95% CI: 0.84-0.99) for MRI, indicating a comparable level of specificity between the two modalities (P=0.22).
CONCLUSION: Our meta-analysis reveals that MRI exhibits higher sensitivity and comparable specificity to TVS in patients with DIE of the RVS. However, the limited number of articles included may affect the evidence of these results. Therefore, further d number of articles included may affect the evidence of these results. Therefore, further research with larger sample sizes and prospective designs is essential to validate these findings.
引用
- Lou Y, Li D, Yu J, et al. Diagnostic performance of transvaginal sonography vs. magnetic resonance imaging for rectovaginal septum deep infiltrating endometriosis: a head-to-head comparative meta-analysis. Clin Radiol. 2024. PMID: 38797608. doi:10.1016/j.crad.2024.05.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。