文献速递泌尿生殖US

睾丸癌中定量微血流血管指数的评估

Assessment of quantitative microflow Vascular Index in testicular cancer.
PubMed 文献 · Eur J Radiol · 2024-05-18

该回顾性分析纳入2018至2022年在本院行睾丸超声的62例患者(正常31例、睾丸肿瘤31例),采用标准化SMI默认设置测定血管指数(VI)。正常睾丸VI中位数2.5%,睾丸肿瘤17.4%,两者差异有统计学意义(p < 0.001);VI可区分精原细胞瘤(14.8%)、非精原细胞瘤(17.6%)与淋巴瘤(34.5%)(p = 0.030)。作者认为VI是有用的定量参数,但需在更大研究人群中进一步确认。

要点

  • 正常睾丸VI中位数为2.5%,睾丸肿瘤为17.4%,两者差异有统计学意义(p < 0.001)。
  • VI可区分精原细胞瘤(中位数14.8%)、非精原细胞瘤(17.6%)与淋巴瘤(34.5%),p = 0.030。
  • 血管形态模式同样可区分上述肿瘤类型(p < 0.001)。

核心结论

  • VI是一种可定量、能为鉴别睾丸肿瘤类型提供额外信息的工具,作者认为其可能是有用的定量参数,但需在更大研究人群中进一步确认。

研究设计与样本

  • 回顾性分析,纳入2018至2022年在本院行睾丸超声的患者62例(正常31例、睾丸肿瘤31例),采用Aplio i800/i900超声系统(Canon Medical Systems Corporation,Tochigi,Japan)标准化SMI默认设置(彩色增益44 ± 5),以组织病理学为睾丸肿瘤参考标准,统计方法包括卡方检验、Mann-Whitney U检验与ROC曲线分析。

关键影像表现/征象

  • 正常睾丸VI中位数为2.5%,睾丸肿瘤VI中位数为17.4%,两者差异有统计学意义(p < 0.001)。
  • 血管形态模式在精原细胞瘤、非精原细胞瘤与淋巴瘤之间差异有统计学意义(p < 0.001)。
  • VI在精原细胞瘤(中位数14.8%)、非精原细胞瘤(中位数17.6%)与淋巴瘤(中位数34.5%)之间差异有统计学意义(p = 0.030)。

诊断标准与关键数值

  • SMI-derived VI:正常睾丸中位数2.5%,睾丸肿瘤中位数17.4%(p < 0.001)。
  • VI区分精原细胞瘤(中位数14.8%)、非精原细胞瘤(中位数17.6%)与淋巴瘤(中位数34.5%),p = 0.030。

临床应用与阅片要点

  • 在标准化SMI默认设置(彩色增益44 ± 5)下测定VI,可为鉴别正常睾丸组织与睾丸肿瘤提供定量参考。
  • VI可能为区分精原细胞瘤、非精原细胞瘤与淋巴瘤提供额外定量信息。
  • 作者认为VI可能是有用的定量参数,但需在更大研究人群中进一步确认。

局限性

  • 原文指出需在更大研究人群中进一步确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ultrasound (US) is the primary imaging modality when a testicular tumor is suspected. Superb microvascular imaging (SMI) is a novel, highly sensitive Doppler technique that allows quantification of flow signals by determination of the Vascular Index (VI). The aim of the present study is to investigate the diagnostic significance of the SMI-derived VI in normal testicular tissue and testicular cancer.

METHODS: This retrospective analysis included patients who underwent testicular US in our department from 2018 to 2022. Inclusion criteria were: i) sufficient image quality of the stored images, ii) US with standardized SMI-default setting (colour gain of 44 ± 5), iii) patient age ≥ 18 years, and iv) normal testicular findings or testicular tumor with histopathological workup. US examinations were performed as part of clinical routine using a high-end ultrasound system (Aplio i800/i900, Canon Medical Systems Corporation, Tochigi, Japan). Statistical analysis included Chi-square test and Mann-Whitney U tests and receiver operating characteristic (ROC) curve analysis.

RESULTS: A total of 62 patients (31 each with normal findings and testicular tumors) were included. The VI differed statistically significantly (p < 0.001) between normal testis (median 2.5 %) and testicular tumors (median 17.4 %). Like vascular patterns (p < 0.001), the VI (p = 0.030) was shown to distinguish seminomas (median 14.8 %), non-seminomas (median 17.6 %) and lymphomas (median 34.5 %).

CONCLUSIONS: In conclusion, our study has shown the VI to be a quantitative tool that can add information for differentiating testicular tumor entities. While further confirmation in larger study populations is desirable, our results suggest that the VI may be a useful quantitative parameter.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Spiesecke P, Schmidt J, Peters R, et al. Assessment of quantitative microflow Vascular Index in testicular cancer. Eur J Radiol. 2024. PMID: 38788608. doi:10.1016/j.ejrad.2024.111513

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。