文献速递泌尿生殖US

三维多参数超声成像能否预测前列腺穿刺活检结果

Can 3D Multiparametric Ultrasound Imaging Predict Prostate Biopsy Outcome?
PubMed 文献 · Ultrasound Med Biol · 2024-05-11

研究纳入54例未穿刺过的患者,行三维动态对比增强超声与多平面二维剪切波弹性成像,重建三维图并分区对应12针系统穿刺。基于血流动力学与组织硬度定量及影像组学特征构建多参数超声模型,检测临床显著前列腺癌的AUC达0.85,优于单用血流动力学参数的0.81。

要点

  • 三维多参数超声联合血流动力学与组织硬度定量,检测临床显著前列腺癌的AUC为0.85。
  • 单用血流动力学参数的影像组学特征,AUC为0.81。
  • 18个血流动力学参数的平均AUC范围为0.63至0.75,剪切波弹性AUC为0.66。

核心结论

  • 三维多参数超声成像联合血流动力学与组织硬度特征,可能是预测穿刺活检结果、辅助定位临床显著前列腺癌的有前景诊断工具。

研究设计与样本

  • 研究纳入54例未穿刺过的患者,行三维动态对比增强超声记录、从基底到尖部的多平面二维剪切波弹性扫描及12针系统穿刺。

诊断标准与关键数值

  • 以系统穿刺为参考,临床显著前列腺癌检测的多参数模型AUC为0.85,采用梯度提升分类器。
  • 单用血流动力学参数的影像组学特征模型AUC为0.81。
  • 18个血流动力学参数的平均AUC范围为0.63至0.75,剪切波弹性AUC为0.66。
  • 多参数联合较单用血流动力学参数AUC显著提高至0.85,P值小于0.05。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the value of 3D multiparametric ultrasound imaging, combining hemodynamic and tissue stiffness quantifications by machine learning, for the prediction of prostate biopsy outcomes.

METHODS: After signing informed consent, 54 biopsy-naïve patients underwent a 3D dynamic contrast-enhanced ultrasound (DCE-US) recording, a multi-plane 2D shear-wave elastography (SWE) scan with manual sweeping from base to apex of the prostate, and received 12-core systematic biopsies (SBx). 3D maps of 18 hemodynamic parameters were extracted from the 3D DCE-US quantification and a 3D SWE elasticity map was reconstructed based on the multi-plane 2D SWE acquisitions. Subsequently, all the 3D maps were segmented and subdivided into 12 regions corresponding to the SBx locations. Per region, the set of 19 computed parameters was further extended by derivation of eight radiomic features per parameter. Based on this feature set, a multiparametric ultrasound approach was implemented using five different classifiers together with a sequential floating forward selection method and hyperparameter tuning. The classification accuracy with respect to the biopsy reference was assessed by a group-k-fold cross-validation procedure, and the performance was evaluated by the Area Under the Receiver Operating Characteristics Curve (AUC).

RESULTS: Of the 54 patients, 20 were found with clinically significant prostate cancer (csPCa) based on SBx. The 18 hemodynamic parameters showed mean AUC values varying from 0.63 to 0.75, and SWE elasticity showed an AUC of 0.66. The multiparametric approach using radiomic features derived from hemodynamic parameters only produced an AUC of 0.81, while the combination of hemodynamic and tissue-stiffness quantifications yielded a significantly improved AUC of 0.85 for csPCa detection (p-value < 0.05) using the Gradient Boosting classifier.

CONCLUSIONS: Our results suggest 3D multiparametric ultrasound imaging combining hemodynamic and tissue-stiffness features to represent a promising diagnostic tool for biopsy outcome prediction, aiding in csPCa localization.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Chen P, Turco S, Wang Y, et al. Can 3D Multiparametric Ultrasound Imaging Predict Prostate Biopsy Outcome? Ultrasound Med Biol. 2024. PMID: 38734528. doi:10.1016/j.ultrasmedbio.2024.04.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。