校正门静脉期静脉对比剂对自动化CT身体成分测量的影响
本研究纳入1612名老年人,均接受统一的CT尿路上皮方案(平扫、门静脉期、延迟排泄期)。将全自动CT算法用于平扫和门静脉期,量化肌肉和脂肪面积与密度、骨密度及实质器官体积,分析静脉对比剂对这些身体成分测量的影响,并推导线性关系以将门静脉期测量值转换为平扫等效值。结果显示所有自动化软组织测量在平扫与门静脉期之间呈极好正线性相关(r²=0.91-0.99),骨衰减呈中度正线性相关(r²=0.58-0.76)。结论认为门静脉期腹部CT的全自动定量CT生物标志物测量可通过简单线性关系校正为平扫等效值。
要点
- 门静脉期与平扫的自动化软组织测量值呈极好正线性相关(r²=0.91-0.99)。
- 骨衰减的平扫与门静脉期相关性为中度正线性相关(r²=0.58-0.76)。
- 面积和体积测量所需校正小于衰减测量。
核心结论
- 门静脉期腹部CT的全自动定量CT生物标志物测量可通过简单线性关系校正为平扫等效值。
研究设计与样本
- 研究纳入1612名老年人(平均年龄68.0岁,594名女性),均采用统一的CT尿路上皮方案,包括平扫、门静脉期和延迟排泄期。
关键影像表现/征象
- 所有自动化软组织测量在平扫与门静脉期之间呈极好正线性相关(r²=0.91-0.99)。
- 骨衰减在平扫与门静脉期之间呈中度正线性相关(r²=0.58-0.76)。
- 面积和体积测量所需校正小于衰减测量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Fully-automated CT-based algorithms for quantifying numerous biomarkers have been validated for unenhanced abdominal scans. There is great interest in optimizing the documentation and reporting of biophysical measures present on all CT scans for the purposes of opportunistic screening and risk profiling. The purpose of this study was to determine and adjust the effect of intravenous (IV) contrast on these automated body composition measures at routine portal venous phase post-contrast imaging.
METHODS: Final study cohort consisted of 1,612 older adults (mean age, 68.0 years; 594 women) all imaged utilizing a uniform CT urothelial protocol consisting of pre-contrast, portal venous, and delayed excretory phases. Fully-automated CT-based algorithms for quantifying numerous biomarkers, including muscle and fat area and density, bone mineral density, and solid organ volume were applied to pre-contrast and portal venous phases. The effect of IV contrast upon these body composition measures was analyzed. Regression analyses, including square of the Pearson correlation coefficient (r2), were performed for each comparison.
RESULTS: We found that simple, linear relationships can be derived to determine non-contrast equivalent values from the post-contrast CT biomeasures. Excellent positive linear correlation (r2 = 0.91-0.99) between pre- and post-contrast values was observed for all automated soft tissue measures, whereas moderate positive linear correlation was observed for bone attenuation (r2 = 0.58-0.76). In general, the area- and volume-based measurement require less adjustment than attenuation-based measures, as expected.
CONCLUSION: Fully-automated quantitative CT-biomarker measures at portal venous phase abdominal CT can be adjusted to a non-contrast equivalent using simple, linear relationships.
引用
- Moeller AR, Garrett JW, Summers RM, et al. Adjusting for the effect of IV contrast on automated CT body composition measures during the portal venous phase. Abdom Radiol (NY). 2024. PMID: 38744704. doi:10.1007/s00261-024-04376-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。