文献速递腹部US

基于Sonazoid超声造影Kupffer期影像组学特征构建的联合模型用于诊断高分化肝细胞癌与非典型局灶性肝脏病变:一项前瞻性多中心研究

A combined model based on radiomics features of Sonazoid contrast-enhanced ultrasound in the Kupffer phase for the diagnosis of well-differentiated hepatocellular carcinoma and atypical focal liver lesions: a prospective, multicenter study.
PubMed 文献 · Abdom Radiol (NY) · 2024-05-14

该前瞻性多中心研究纳入116例经Sonazoid超声造影确认的高分化肝细胞癌或良性局灶性肝脏病变患者,按7:3随机分为训练队列(79例)和测试队列(37例),基于Kupffer期影像组学特征构建影像组学模型和联合模型。联合模型在训练队列和测试队列的AUC分别为0.951和0.912,均优于影像组学模型(AUC分别为0.905和0.826)。决策曲线分析显示联合模型在0.25至1.00的阈值概率范围内具有更高的净获益,并构建了列线图以减少不必要的活检。

要点

  • 联合模型在测试队列诊断高分化肝细胞癌与非典型良性局灶性肝脏病变的AUC为0.912,优于影像组学模型的0.826。
  • 联合模型在训练队列AUC为0.951,影像组学模型为0.905。
  • 决策曲线分析显示联合模型在阈值概率0.25至1.00范围内净获益更高。

核心结论

  • 基于Sonazoid超声造影Kupffer期影像组学特征的联合模型在诊断高分化肝细胞癌与非典型良性局灶性肝脏病变方面表现出满意性能,可辅助临床医生及时发现恶性局灶性肝脏病变并减少良性病变的不必要活检。

研究设计与样本

  • 前瞻性多中心研究,纳入2020年8月至2021年3月期间116例术前Sonazoid超声造影确认的高分化肝细胞癌或良性局灶性肝脏病变患者,按7:3随机分为训练队列(79例)和测试队列(37例)。

诊断标准与关键数值

  • 联合模型训练队列AUC为0.951,测试队列AUC为0.912;影像组学模型训练队列AUC为0.905,测试队列AUC为0.826;决策曲线分析显示联合模型在阈值概率0.25至1.00范围内净获益更高。

临床应用与阅片要点

  • 联合模型列线图可用于评估减少不必要活检的价值,辅助临床医生及时发现恶性局灶性肝脏病变并减少良性病变的不必要活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to develop a combined model based on radiomics features of Sonazoid contrast-enhanced ultrasound (CEUS) during the Kupffer phase and to evaluate its value in differentiating well-differentiated hepatocellular carcinoma (w-HCC) from atypical benign focal liver lesions (FLLs).

METHODS: A total of 116 patients with preoperatively Sonazoid-CEUS confirmed w-HCC or benign FLL were selected from a prospective multiple study on the clinical application of Sonazoid in FLLs conducted from August 2020 to March 2021. According to the randomization principle, the patients were divided into a training cohort and a test cohort in a 7:3 ratio. Seventy-nine patients were used for establishing and training the radiomics model and combined model. In comparison, 37 patients were used for validating and comparing the performance of the models. The diagnostic efficacy of the models for w-HCC and atypical benign FLLs was evaluated using ROCs curves and decision curves. A combined model nomogram was created to assess its value in reducing unnecessary biopsies.

RESULTS: Among the patients, there were 55 cases of w-HCC and 61 cases of atypical benign FLLs, including 28 cases of early liver abscess, 16 cases of atypical hepatic hemangioma, 8 cases of hepatocellular dysplastic nodules (DN), and 9 cases of focal nodular hyperplasia (FNH). The radiomics model and combined model we established had AUCs of 0.905 and 0.951, respectively, in the training cohort, and the AUCs of the two models in the test cohort were 0.826 and 0.912, respectively. The combined model outperformed the radiomics feature model significantly. Decision curve analysis demonstrated that the combined model achieved a higher net benefit within a specific threshold probability range (0.25 to 1.00). A nomogram of the combined model was developed.

CONCLUSION: The combined model based on the radiomics features of Sonazoid-CEUS in the Kupffer phase showed satisfactory performance in diagnosing w-HCC and atypical benign FLLs. It can assist clinicians in timely detecting malignant FLLs and reducing unnecessary biopsies for benign diseases.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Wang Z, Yao J, Jing X, et al. A combined model based on radiomics features of Sonazoid contrast-enhanced ultrasound in the Kupffer phase for the diagnosis of well-differentiated hepatocellular carcinoma and atypical focal liver lesions: a prospective, multicenter study. Abdom Radiol (NY). 2024. PMID: 38744698. doi:10.1007/s00261-024-04253-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。