文献速递腹部儿科影像技术与安全USMRCT

儿童与成人胆道树正常形态测量:系统综述与荟萃分析

Normal morphometry of the biliary tree in pediatric and adult populations: A systematic review and meta-analysis.
PubMed 文献 · Eur J Radiol · 2024-04-18

该系统综述与荟萃分析纳入60项研究,其中44项提供可提取数据,共23,796名受试者,汇总胆总管平均直径为4.69 mm(95%CI 4.28-5.11);儿童胆总管直径1.32 mm(95%CI 1.03-1.61)显著小于成人4.97 mm(95%CI 4.67-5.27);超声测量3.82 mm(95%CI 3.15-4.49)显著小于MRI 6.21 mm(95%CI 4.85-7.57)和ERCP 7.24 mm(95%CI 6.08-8.40);胆总管远端直径5.20 mm(95%CI 4.60-5.80)显著大于近端4.01 mm(95%CI 3.51-4.51)。

要点

  • 儿童胆总管直径1.32 mm(95%CI 1.03-1.61)显著小于成人4.97 mm(95%CI 4.67-5.27)。
  • 超声测量胆总管直径3.82 mm(95%CI 3.15-4.49)显著小于MRI 6.21 mm(95%CI 4.85-7.57)。
  • 胆总管远端直径5.20 mm(95%CI 4.60-5.80)显著大于近端4.01 mm(95%CI 3.51-4.51)。

核心结论

  • 这项基于证据的研究结果可能有助于建立儿童和成人胆道树正常参考值和范围的标准,并促进临床理解。

研究设计与样本

  • 系统综述与荟萃分析,遵循PRISMA指南并在PROSPERO注册,检索MEDLINE、EMBASE、SCOPUS和Web of Science数据库至2022年10月并更新至2023年8月;共纳入60项研究,其中44项研究提供可提取数据进行荟萃分析,共23,796名受试者;使用解剖学质量评估(AQUA)工具评估纳入研究质量;按性别、年龄、地理位置和成像方式进行了亚组分析。

诊断标准与关键数值

  • 胆总管汇总平均直径为4.69 mm(95%CI 4.28-5.11)。
  • 儿童胆总管直径1.32 mm(95%CI 1.03-1.61)vs 成人4.97 mm(95%CI 4.67-5.27),儿童显著小于成人。
  • 超声测量胆总管直径3.82 mm(95%CI 3.15-4.49)vs MRI 6.21 mm(95%CI 4.85-7.57)vs ERCP 7.24 mm(95%CI 6.08-8.40),超声测量值显著小于MRI和ERCP。
  • 胆总管远端直径5.20 mm(95%CI 4.60-5.80)vs 近端4.01 mm(95%CI 3.51-4.51),远端显著大于近端。

临床应用与阅片要点

  • 作者认为该研究结果可能有助于建立儿童和成人胆道树正常参考值和范围的标准,并促进临床理解。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aimed to characterise the normal morphometry of the biliary tree in pediatric and adult populations, through a systematic review and meta-analysis.

METHODS: This study, conducted using the PRISMA guidelines and registered with PROSPERO, searched MEDLINE, EMBASE, SCOPUS and Web of Science databases up to October 2022, and updated to August 2023. Studies that reported extractable data on diameter and length of the right, left and common hepatic ducts (LHD, RHD and CHD), and common bile duct (CBD) were included. Quality of the included studies were assessed using the Anatomical Quality Assessment (AQUA) tool. Statistical analysis included subgroup analyses according to sex, age, geographical location, and imaging modality.

RESULTS: In total, 60 studies were included, of which 44 studies reported adequate data for meta-analysis on 23,796 subjects. Overall, the pooled mean diameter of the CBD was 4.69 mm (95 % CI: 4.28-5.11). Significant differences were found between pediatric (1.32 mm, 95 % CI: 1.03-1.61) and adult (4.97 mm, 95 % CI: 4.67-5.27) subjects, as well as US (3.82 mm, 95 % CI: 3.15-4.49) and other imaging modalities, including MRI (6.21 mm, 95 % CI: 4.85-7.57) and ERCP (7.24 mm, 95 % CI: 6.08-8.40). The CBD diameter measured significantly larger distally (5.20 mm, 95 % CI: 4.60-5.80) than proximally (4.01 mm, 95 % CI: 3.51-4.51).

CONCLUSIONS: The results obtained from this evidence-based study may guide the establishment of standardised reference values and ranges of the normal biliary tree in pediatric and adult populations and aid clinical understanding.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Chau P, Moses D, Pather N, et al. Normal morphometry of the biliary tree in pediatric and adult populations: A systematic review and meta-analysis. Eur J Radiol. 2024. PMID: 38718450. doi:10.1016/j.ejrad.2024.111472

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。