文献速递腹部技术与安全CT

双能CT在肝脏成像中的应用:放射科医生和技师应了解什么?一项系统综述

Dual-energy CT applications on liver imaging: what radiologists and radiographers should know? A systematic review.
PubMed 文献 · Abdom Radiol (NY) · 2024-05-30

本系统综述检索1980至2024年MEDLINE/EMBASE上关于肝脏双能CT(DECT)的研究,最终纳入153篇。文章汇总了DECT技术、采集流程和后处理方法,比较其与传统单能CT的优缺点,发现采集参数差异大,主要应用为检出局灶性肝病变(47%),并推荐使用80/140 kVp管电压、碘对比剂1.5 mL/kg、流率3-4 mL/s,后处理包括低keV虚拟单能图像、碘图及虚拟平扫。

要点

  • 推荐管电压80/140 kVp,碘对比剂1.5 mL/kg、流率3-4 mL/s。
  • 后处理推荐低keV虚拟单能图像增强病变检出,碘图评估肿瘤碘含量,虚拟平扫降低剂量。
  • 文献异质性妨碍协议标准化,采集参数除管电压和碘对比剂给药外差异广泛。

核心结论

  • 本综述推荐使用80/140 kVp管电压、碘对比剂1.5 mL/kg、流率3-4 mL/s,后处理应包括低keV虚拟单能图像增强病变检出、碘图评估肿瘤碘含量、虚拟平扫降低剂量;但文献异质性妨碍协议标准化。

研究设计与样本

  • 系统综述,检索MEDLINE/EMBASE 1980至2024年发表的肝脏DECT研究,最终纳入153篇文章。

关键影像表现/征象

  • DECT后处理图像的主要应用为检出局灶性肝病变,占47%的文章。
  • 研究以肝细胞癌(HCC)为主,占27%的文章。
  • 16%的文章关注优化DECT协议,15%的文章探索转移瘤检出。
  • 虚拟平扫(VNC)成为降低辐射剂量的常见策略。

诊断标准与关键数值

  • 管电压80/140 kVp组合在50%的文章中报告。
  • 碘对比剂给药1.5 mL/kg、流率3-4 mL/s,在91%的文章中报告。
  • 辐射剂量信息仅在40%的文章中提供,范围为6-80 mGy。

临床应用与阅片要点

  • 本综述推荐使用80/140 kVp管电压、碘对比剂1.5 mL/kg、流率3-4 mL/s。
  • 后处理应包括低keV虚拟单能图像增强病变检出、碘图评估肿瘤碘含量、虚拟平扫降低剂量。
  • 文献异质性妨碍协议标准化。

局限性

  • 文献异质性妨碍协议标准化。
  • 采集参数存在广泛差异,仅管电压(80/140 kVp组合)在50%的文章中报告、碘对比剂给药(1.5 mL/kg、3-4 mL/s)在91%的文章中报告。
  • 辐射剂量信息仅在40%的文章中提供,范围为6-80 mGy。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This review aims to provide a comprehensive summary of DECT techniques, acquisition workflows, and post-processing methods. By doing so, we aim to elucidate the advantages and disadvantages of DECT compared to conventional single-energy CT imaging.

METHODS: A systematic search was conducted on MEDLINE/EMBASE for DECT studies in liver imaging published between 1980 and 2024. Information regarding study design and endpoints, patient characteristics, DECT technical parameters, radiation dose, iodinated contrast agent (ICA) administration and postprocessing methods were extracted. Technical parameters, including DECT phase, field of view, pitch, collimation, rotation time, arterial phase timing (from injection), and venous timing (from injection) from the included studies were reported, along with formal narrative synthesis of main DECT applications for liver imaging.

RESULTS: Out of the initially identified 234 articles, 153 met the inclusion criteria. Extensive variability in acquisition parameters was observed, except for tube voltage (80/140 kVp combination reported in 50% of articles) and ICA administration (1.5 mL/kg at 3-4 mL/s, reported in 91% of articles). Radiation dose information was provided in only 40% of articles (range: 6-80 mGy), and virtual non-contrast imaging (VNC) emerged as a common strategy to reduce the radiation dose. The primary application of DECT post-processed images was in detecting focal liver lesions (47% of articles), with predominance of study focusing on hepatocellular carcinoma (HCC) (27%). Furthermore, a significant proportion of the articles (16%) focused on enhancing DECT protocols, while 15% explored metastasis detection.

CONCLUSION: Our review recommends using 80/140 kVp tube voltage with 1.5 mL/kg ICA at 3-4 mL/s flow rate. Post-processing should include low keV-VMI for enhanced lesion detection, IMs for tumor iodine content evaluation, and VNC for dose reduction. However, heterogeneous literature hinders protocol standardization.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Asmundo L, Rizzetto F, Srinivas Rao S, et al. Dual-energy CT applications on liver imaging: what radiologists and radiographers should know? A systematic review. Abdom Radiol (NY). 2024. PMID: 38811447. doi:10.1007/s00261-024-04380-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。