应用斑点追踪超声心动图评估血红蛋白巴特病胎儿的心脏表现
这项前瞻性队列研究纳入115例有胎儿血红蛋白巴特病风险的孕妇,在17至24周孕龄于侵入性产前检测前行胎儿心脏斑点追踪分析。38例(33.0%)胎儿确诊巴特病,其中9例(23.7%)出现胎儿水肿。基于头围校正的斑点追踪心脏测量组合可区分非水肿型巴特病贫血胎儿与未患病胎儿,敏感度100%、特异度98.7%、总准确率99.1%。
要点
- 巴特病贫血胎儿可表现为四腔心切面增大及右心室腔呈球形。
- 非水肿型患病胎儿左心室整体及纵向收缩力较对照组显著降低。
- 基于头围校正的斑点追踪测量组合诊断敏感度100%、特异度98.7%。
核心结论
- 胎儿心脏斑点追踪分析有潜力在孕中期准确识别巴特病贫血的早期胎儿心脏改变,为巴特病贫血提供新的预测标志物,并有助于探讨胎儿贫血相关心力衰竭的机制。
研究设计与样本
- 前瞻性队列研究,纳入2019年1月至2021年1月泰国曼谷Siriraj医院115例有胎儿血红蛋白巴特病风险的单胎妊娠孕妇,均在羊膜腔穿刺或脐带穿刺前于四腔心切面行胎儿心脏斑点追踪分析,以侵入性产前检测结果为参考。
关键影像表现/征象
- 与对照组相比,患病胎儿四腔心切面增大,右心室腔呈球形。
- 与对照组相比,非水肿型患病胎儿左心室整体及纵向收缩力均显著降低。
- 孕中期两组间横向收缩力及左心室功能(射血分数除外)无显著差异。
诊断标准与关键数值
- 基于头围校正的斑点追踪心脏测量组合区分非水肿型巴特病贫血胎儿与未患病胎儿,敏感度100%、特异度98.7%、总准确率99.1%。
- 队列中38例(33.0%)确诊巴特病,其中9例(23.7%)出现胎儿水肿。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Hemoglobin (Hb) Bart's disease is a severe manifestation of alpha-thalassemia, resulting in fetal tissue hypoxia and severe anemia. There is limited research available on assessing speckle-tracking analysis of the fetal heart as a response to fetal anemia caused by Hb Bart's disease. This study aimed to assess the diagnostic performance of fetal cardiac measurements derived from speckle-tracking analysis to identify fetuses with Bart's anemia between 17 and 24 weeks of gestation.
METHODS: This prospective cohort study included 115 women with singleton pregnancies at risk for fetal Hb Bart's disease who underwent either amniocentesis or cordocentesis at Siriraj Hospital, Bangkok, Thailand, in the period between January 2019 and January 2021. Speckle-tracking analysis of the fetal heart was performed in the four-chamber view (4CV), assessing ventricular size and shape, ventricular contractility and left ventricular function, prior to invasive prenatal testing. Logistic regression analysis was used to determine significant cardiac predictors and calculate the probability of a fetus having Hb Bart's anemia.
RESULTS: Among the cohort, 38 (33.0%) fetuses were diagnosed with Hb Bart's disease, and of these, nine (23.7%) cases exhibited fetal hydrops. In comparison to the control group, affected fetuses displayed enlargement of the 4CV, with a globular shape of the right ventricular chamber. Additionally, there were significant reductions in both global and longitudinal left ventricular contractility in non-hydropic affected fetuses compared with the controls. At mid-gestation, no significant differences were observed in transverse contractility or left ventricular function, except for the ejection fraction, between the two groups. Based on logistic regression analysis, combined cardiac measurements derived from speckle-tracking analysis, as a function of head circumference, could differentiate non-hydropic fetuses with Hb Bart's anemia from unaffected fetuses, achieving a sensitivity of 100%, specificity of 98.7% and overall accuracy of 99.1%.
CONCLUSIONS: Speckle-tracking analysis of the fetal heart has the potential to accurately identify early fetal cardiac changes during the second trimester in individuals with Bart's anemia. These findings not only offer a novel predictive marker for Hb Bart's anemia, but also help address the question of the underlying mechanisms of heart failure associated with fetal anemia. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Anuwutnavin S, Russameecharoen K, Ruangvutilert P, et al. Evaluation of cardiac findings using speckle-tracking echocardiography in fetuses with hemoglobin Bart's disease. Ultrasound Obstet Gynecol. 2024. PMID: 38706423. doi:10.1002/uog.27676
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。