CT引导下肺活检中降低气胸风险:肺穿刺前向胸膜注入液体及胸膜压重力效应的影响
该单中心回顾性研究分析2020年1月至2023年4月72例CT引导下经皮肺活检,按活检时是否向胸膜下或胸膜腔注入10 ml 1%利多卡因液体及活检区域是否为重力依赖区分组。结果显示注液和重力依赖区活检均与较低围干预期气胸发生率显著相关,多因素校正后仍独立相关(注液病灶OR 0.071,p≤.01;重力依赖区病灶OR 0.077,p=.016)。
要点
- 穿刺前向胸膜下或胸膜腔注入10 ml 1%利多卡因液体与气胸风险降低独立相关(OR 0.071,p≤.01)。
- 在重力依赖区进行活检与气胸风险降低独立相关(OR 0.077,p=.016)。
- 注液且重力依赖区活检组气胸发生率为0%(n=0),未注液非依赖区组为65%(n=15)。
核心结论
- 穿刺前向胸膜注入液体及考虑患者体位重力效应可有效减少CT引导下肺活检的气胸发生。
研究设计与样本
- 单中心回顾性分析,纳入2020年1月至2023年4月72例经皮CT引导下肺活检,按活检时是否注液及活检区域是否为重力依赖区分组,采用Kruskal-Wallis检验、Fisher精确检验和多因素逻辑回归分析。
诊断标准与关键数值
- 围干预期气胸发生率:未注液非依赖区65%(n=15)、未注液依赖区42%(n=5)、注液非依赖区36%(n=5)、注液依赖区0%(n=0),p=.001;多因素校正后注液病灶OR 0.071(p≤.01),依赖区病灶OR 0.077(p=.016)。
临床应用与阅片要点
- 作者结论认为穿刺前向胸膜注液及体位重力效应可有效减少气胸发生。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study investigated strategies to reduce pneumothorax risk in CT-guided lung biopsy. The approach involved administering 10 ml of 1 % lidocaine fluid in the subpleural or pleural space before lung puncture and utilizing the gravitational effect of pleural pressure with specific patient positioning.
METHOD: We retrospectively analyzed 72 percutaneous CT-guided lung biopsies performed at a single center between January 2020 and April 2023. These were grouped based on fluid administration during the biopsy and whether the biopsies were conducted in dependent or non-dependent lung regions. Confounding factors like patient demographics, lesion characteristics, and procedural details were assessed. Patient characteristics and the occurrence of pneumothoraces were compared using a Kurskal-Wallis test for continuous variables and a Fisher's exact test for categorical variables. Multivariable logistic regression was used to identify potential confounders.
RESULTS: Subpleural or pleural fluid administration and performing biopsies in dependent lung areas were significantly linked to lower peri-interventional pneumothorax incidence (n = 15; 65 % without fluid in non-dependent areas, n = 5; 42 % without fluid in dependent areas, n = 5; 36 % with fluid in non-dependent areas,n = 0; 0 % with fluid in dependent areas; p = .001). Even after adjusting for various factors, biopsy in dependent areas and fluid administration remained independently associated with reduced pneumothorax risk (OR 0.071, p<=.01 for lesions with fluid administration; OR 0.077, p = .016 for lesions in dependent areas).
CONCLUSIONS: Pre-puncture fluid administration to the pleura and consideration of gravitational effects during patient positioning can effectively decrease pneumothorax occurrences in CT-guided lung biopsy.
引用
- Brönnimann MP, Christe A, Heverhagen JT, et al. Pneumothorax risk reduction during CT-guided lung biopsy - Effect of fluid application to the pleura before lung puncture and the gravitational effect of pleural pressure. Eur J Radiol. 2024. PMID: 38810440. doi:10.1016/j.ejrad.2024.111529
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。