文献速递腹部技术与安全CT

基于增强CT的深度学习影像组学模型用于鉴别肝转移瘤的原发来源

Deep Learning Radiomics Model of Contrast-Enhanced CT for Differentiating the Primary Source of Liver Metastases.
PubMed 文献 · Acad Radiol · 2024-05-03

研究收集三个临床中心2018年1月至2023年10月共428例患者的657个肝转移病灶(乳腺癌、肺癌、结直肠癌、胃癌、胰腺癌),按7:3随机分为训练集与验证集,另取另一中心61例患者的112个病灶作为外部测试集,构建基于肝脏增强CT的深度学习影像组学模型,采用逐步分类策略鉴别五种病理类型,并以经典机器学习模型作为对照,用准确率和AUC评价模型性能。

要点

  • 模型在验证集五分类任务中最高准确率0.563、平均AUC 0.796。
  • 消化道癌与非消化道癌分类任务AUC 0.907、准确率0.843。
  • 肺癌与乳腺癌分类任务AUC 0.809、准确率0.772。

核心结论

  • 基于增强CT的深度学习影像组学模型是鉴别肝转移瘤原发来源的有效方法。

研究设计与样本

  • 研究纳入三个临床中心2018年1月至2023年10月共428例患者的657个肝转移病灶,按7:3随机分为训练集与验证集;另取另一临床中心61例患者的112个病灶作为外部测试集,构建基于肝脏增强CT的深度学习影像组学模型,并以经典机器学习模型作为对照。

诊断标准与关键数值

  • 五分类任务验证集最高准确率0.563、平均AUC 0.796。
  • 消化道癌与非消化道癌分类任务AUC 0.907、准确率0.843。
  • 肺癌与乳腺癌分类任务AUC 0.809、准确率0.772。
  • 结直肠癌、胃癌与胰腺癌分类任务准确率0.714、平均AUC 0.811。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and validate a deep learning radiomics (DLR) model based on contrast-enhanced computed tomography (CT) to identify the primary source of liver metastases.

MATERIALS AND METHODS: In total, 657 liver metastatic lesions, including breast cancer (BC), lung cancer (LC), colorectal cancer (CRC), gastric cancer (GC), and pancreatic cancer (PC), from 428 patients were collected at three clinical centers from January 2018 to October 2023 series. The lesions were randomly assigned to the training and validation sets in a 7:3 ratio. An additional 112 lesions from 61 patients at another clinical center served as an external test set. A DLR model based on contrast-enhanced CT of the liver was developed to distinguish the five pathological types of liver metastases. Stepwise classification was performed to improve the classification efficiency of the model. Lesions were first classified as digestive tract cancer (DTC) and non-digestive tract cancer (non-DTC). DTCs were divided into CRC, GC, and PC and non-DTCs were divided into LC and BC. To verify the feasibility of the DLR model, we trained classical machine learning (ML) models as comparison models. Model performance was evaluated using accuracy (ACC) and area under the receiver operating characteristic curve (AUC).

RESULTS: The classification model constructed by the DLR algorithm showed excellent performance in the classification task compared to ML models. Among the five categories task, highest ACC and average AUC were achieved at 0.563 and 0.796 in the validation set, respectively. In the DTC and non-DTC and the LC and BC classification tasks, AUC was achieved at 0.907 and 0.809 and ACC was achieved at 0.843 and 0.772, respectively. In the CRC, GC, and PC classification task, ACC and average AUC were the highest, at 0.714 and 0.811, respectively.

CONCLUSION: The DLR model is an effective method for identifying the primary source of liver metastases.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Jia W, Li F, Cui Y, et al. Deep Learning Radiomics Model of Contrast-Enhanced CT for Differentiating the Primary Source of Liver Metastases. Acad Radiol. 2024. PMID: 38702214. doi:10.1016/j.acra.2024.04.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。