利用超极化129Xe磁共振评估衰老、吸烟和慢性阻塞性肺疾病引起的肺生理变化
研究纳入90名受试者分为健康年轻组、年龄匹配对照组、无症状吸烟者和COPD患者,使用超极化129Xe磁共振测量通气缺陷百分比、肺泡套深度、表观扩散系数、总间隔壁厚度及红细胞与组织血浆信号比,发现衰老、吸烟和COPD导致肺结构和功能改变呈进行性恶化。
要点
- 超极化129Xe MR可无创评估与衰老、吸烟和COPD相关的肺生理变化。
- COPD患者较年龄匹配对照组VDP、d和ADC升高,h和RBC/TP降低。
- 无症状吸烟者较年龄匹配对照组VDP和d升高。
核心结论
- 衰老、吸烟和COPD引起的肺结构和功能改变各不相同,并随着吸烟和COPD等危险因素的累积呈进行性恶化。
研究设计与样本
- 研究共纳入90名受试者,分为健康年轻组(n=20)、年龄匹配对照组(n=20)、无症状吸烟者组(n=28)和COPD患者组(n=22),使用129Xe MR获取肺生理参数。
关键影像表现/征象
- COPD患者较年龄匹配对照组VDP更高(p<0.001)、d更高(p<0.001)、ADC更高(p<0.001),h更低(p<0.001)和RBC/TP更低(p<0.001)。
- 无症状吸烟者较年龄匹配对照组VDP更高(p=0.020)和d更高(p=0.048)。
- 健康年轻组与年龄匹配对照组之间VDP(p=0.035)、h(p=0.003)和RBC/TP(p=0.003)存在显著差异。
- 无症状吸烟者与COPD患者之间VDP(p<0.001)、h(p<0.001)、ADC(p<0.001)、d(p=0.008)和RBC/TP(p=0.032)存在显著差异。
临床应用与阅片要点
- 129Xe MR可评估与衰老、吸烟和COPD相关的肺结构及功能变化,有助于分期和评估疾病的病因。
- 常规肺功能和胸部CT在评估肺病理生理变化方面存在局限性,129Xe MR可展示多种常见因素引起的结构和功能改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To comprehensively assess the impact of aging, cigarette smoking, and chronic obstructive pulmonary disease (COPD) on pulmonary physiology using 129Xe MR.
METHODS: A total of 90 subjects were categorized into four groups, including healthy young (HY, n = 20), age-matched control (AMC, n = 20), asymptomatic smokers (AS, n = 28), and COPD patients (n = 22). 129Xe MR was utilized to obtain pulmonary physiological parameters, including ventilation defect percent (VDP), alveolar sleeve depth (h), apparent diffusion coefficient (ADC), total septal wall thickness (d), and ratio of xenon signal from red blood cells and interstitial tissue/plasma (RBC/TP).
RESULTS: Significant differences were found in the measured VDP (p = 0.035), h (p = 0.003), and RBC/TP (p = 0.003) between the HY and AMC groups. Compared with the AMC group, higher VDP (p = 0.020) and d (p = 0.048) were found in the AS group; higher VDP (p < 0.001), d (p < 0.001) and ADC (p < 0.001), and lower h (p < 0.001) and RBC/TP (p < 0.001) were found in the COPD group. Moreover, significant differences were also found in the measured VDP (p < 0.001), h (p < 0.001), ADC (p < 0.001), d (p = 0.008), and RBC/TP (p = 0.032) between the AS and COPD groups.
CONCLUSION: Our findings indicate that pulmonary structure and functional changes caused by aging, cigarette smoking, and COPD are various, and show a progressive deterioration with the accumulation of these risk factors, including cigarette smoking and COPD.
CLINICAL RELEVANCE STATEMENT: Pathophysiological changes can be difficult to comprehensively understand due to limitations in common techniques and multifactorial etiologies. 129Xe MRI can demonstrate structural and functional changes caused by several common factors and can be used to better understand patients' underlying pathology.
KEY POINTS: Standard techniques for assessing pathophysiological lung function changes, spirometry, and chest CT come with limitations. 129Xe MR demonstrated progressive deterioration with accumulation of the investigated risk factors, without these limitations. 129Xe MR can assess lung changes related to these risk factors to stage and evaluate the etiology of the disease.
引用
- Rao Q, Li H, Zhou Q, et al. Assessment of pulmonary physiological changes caused by aging, cigarette smoking, and COPD with hyperpolarized 129Xe magnetic resonance. Eur Radiol. 2024. PMID: 38748243. doi:10.1007/s00330-024-10800-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。