胸部CT平均强度投影(AIP)重建对胸膜-肺实质异常的诊断性能
研究纳入142例24小时内接受胸部CT和胸片检查的患者,以CT为参考标准,由3名阅片者分别独立评估常规胸片与AIP重建的合成胸片对实变、结节/肿块、线状影、网格状影和胸腔积液的诊断性能。合成胸片各病变敏感度范围分别为45-67%、12-28%、17-33%、2-61%和33-58%,特异度分别为65-83%、83-94%、94-98%、93-100%和79-86%。结论认为AIP重建的合成胸片可用于临床实践中的图像比较及教学目的。
要点
- AIP重建合成胸片对胸腔积液和实变的敏感度相对较高,对结节/肿块及网格状影敏感度低。
- 合成胸片对各病变特异度均较高,网格状影特异度达93-100%。
- 阅片者间一致性在结节/肿块、线状影和网格状影上较低,K值范围分别为0.05-0.25、-0.05-0.11和-0.01-0.15。
核心结论
- AIP技术重建的合成胸片图像可在临床实践及教学目的中与常规图像进行比较。
研究设计与样本
- 回顾性研究,纳入142例在24小时内接受胸部CT和胸片检查的患者,以CT为标准参考;3名阅片者在两个独立环节分别评估常规胸片和合成胸片。
诊断标准与关键数值
- 合成胸片实变敏感度45-67%、特异度65-83%、准确率66-68%。
- 合成胸片结节/肿块敏感度12-28%、特异度83-94%、准确率74-79%。
- 合成胸片线状影敏感度17-33%、特异度94-98%、准确率89-91%。
- 合成胸片网格状影敏感度2-61%、特异度93-100%、准确率61-65%。
- 合成胸片胸腔积液敏感度33-58%、特异度79-86%、准确率68-72%。
临床应用与阅片要点
- 合成胸片可用于与常规胸片进行对比,但结节/肿块、线状影和网格状影的敏感度较低,阅片者间一致性亦低。
- 合成胸片对网格状影的敏感度范围宽(2-61%),阅片时需注意其检出能力有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: The comparison between chest x-ray (CXR) and computed tomography (CT) images is commonly required in clinical practice to assess the evolution of chest pathological manifestations. Intrinsic differences between the two techniques, however, limit reader confidence in such a comparison. CT average intensity projection (AIP) reconstruction allows obtaining "synthetic" CXR (s-CXR) images, which are thought to have the potential to increase the accuracy of comparison between CXR and CT imaging. We aim at assessing the diagnostic performance of s-CXR imaging in detecting common pleuro-parenchymal abnormalities.
MATERIALS AND METHODS: 142 patients who underwent chest CT examination and CXR within 24 hours were enrolled. CT was the standard of reference. Both conventional CXR (c-CXR) and s-CXR images were retrospectively reviewed for the presence of consolidation, nodule/mass, linear opacities, reticular opacities, and pleural effusion by 3 readers in two separate sessions. Sensitivity, specificity, accuracy and their 95% confidence interval were calculated for each reader and setting and tested by McNemar test. Inter-observer agreement was tested by Cohen's K test and its 95%CI.
RESULTS: Overall, s-CXR sensitivity ranged 45-67% for consolidation, 12-28% for nodule/mass, 17-33% for linear opacities, 2-61% for reticular opacities, and 33-58% for pleural effusion; specificity 65-83%, 83-94%, 94-98%, 93-100% and 79-86%; accuracy 66-68%, 74-79%, 89-91%, 61-65% and 68-72%, respectively. K values ranged 0.38-0.50, 0.05-0.25, -0.05-0.11, -0.01-0.15, and 0.40-0.66 for consolidation, nodule/mass, linear opacities, reticular opacities, and pleural effusion, respectively.
CONCLUSION: S-CXR images, reconstructed with AIP technique, can be compared with conventional images in clinical practice and for educational purposes.
引用
- Ledda RE, Schirò S, Leo L, et al. Diagnostic performance of chest CT average intensity projection (AIP) reconstruction for the assessment of pleuro-parenchymal abnormalities. Clin Radiol. 2024. PMID: 38693034. doi:10.1016/j.crad.2024.04.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。