文献速递胸部介入CT

CT引导下经皮穿刺活检伴囊性含气腔的肺部病变:病例对照研究

CT-Guided Core Needle Biopsy of Pulmonary Lesions Associated With Cystic Airspaces: A Case-Control Study.
PubMed 文献 · AJR Am J Roentgenol · 2024-05-08

回顾性病例对照研究纳入90例伴囊性含气腔肺病变及180例非囊性非空洞病变行CT引导下空心针活检,两组并发症、非诊断性活检率及诊断效能均无显著差异,囊性含气腔病变诊断准确率94%,囊性含气腔多代表肿瘤退变(71%)。

要点

  • 伴囊性含气腔肺病变行CT引导下空心针活检的并发症发生率与对照无显著差异。
  • 非诊断性活检率两组无显著差异(12% vs 9%),假阴性均见于非诊断性活检。
  • 囊性含气腔术后病理多数为肿瘤退变(71%),活检不影响诊断准确性。

核心结论

  • CT引导下空心针活检用于伴囊性含气腔的肺部病变是安全且准确的,有助于避免此类病变的癌症漏诊或延迟诊断。

研究设计与样本

  • 回顾性病例对照研究,纳入2010年2月至2022年12月行CT引导下空心针活检的90例伴囊性含气腔肺病变患者(中位年龄69.5岁,女28例、男62例)及按2:1匹配的180例非囊性非空洞病变对照(中位年龄68.0岁,女56例、男124例),以全部记录联合复核的最终诊断为参考标准。

关键影像表现/征象

  • 伴囊性含气腔病变最终恶性占90%(81/90),非囊性非空洞病变恶性占92%(165/180)。
  • 对活检后手术切除的伴囊性含气腔病变(均为恶性)行组织学复核,囊性含气腔最常见代表肿瘤退变(22/31,71%)。

诊断标准与关键数值

  • 伴囊性含气腔病变组诊断准确率94%(85/90),敏感度94%(76/81),特异度100%(9/9)。
  • 非囊性非空洞病变组诊断准确率97%(175/180),敏感度97%(160/165),特异度100%(15/15)。
  • 两组准确率比较P=.50,敏感度比较P=.50,特异度比较P>.99。
  • 非诊断性活检定义为非特异性良性、非典型细胞或标本不足,伴囊性含气腔组为12%(11/90),对照组为9%(16/180),P=.40。

临床应用与阅片要点

  • 伴囊性含气腔肺病变在CT引导下空心针活检时并发症、非诊断性活检率及诊断效能与非囊性非空洞病变无显著差异。
  • 两组所有恶性假阴性结果均出现在活检结果为非诊断性的患者中。
  • 作者指出空心针活检可能有助于避免伴囊性含气腔肺病变的癌症漏诊或延迟诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Concern may exist that pulmonary lesions associated with cystic airspaces are at risk of increased biopsy complications or lower biopsy accuracy given challenges in targeting tissue abutting or intermingled with the cystic airspaces. OBJECTIVE. The purpose of this study was to evaluate the safety and diagnostic performance of CT-guided core needle biopsy (CNB) of pulmonary lesions associated with cystic airspaces. METHODS. This retrospective study included 90 patients (median age, 69.5 years; 28 women, 62 men) who underwent CT-guided CNB of pulmonary lesions associated with cystic airspaces (based on review of procedural images) from February 2010 to December 2022 and a matched control group (2:1 ratio) of 180 patients (median age, 68.0 years; 56 women, 124 men) who underwent CNB of noncystic noncavitary lesions during the same period. The groups were compared in terms of complications, nondiagnostic biopsies (i.e., nonspecific benignities, atypical cells, or insufficient specimens), and CNB diagnostic performance for detecting malignancy using as reference the final diagnosis from a joint review of all available records. For lesions associated with cystic airspaces that underwent surgical resection after CNB, histologic slides were reviewed to explore the nature of the cystic airspace. RESULTS. The final diagnosis was malignant in 90% (81/90) of lesions associated with cystic airspaces and 92% (165/180) of noncystic noncavitary lesions. Patients with lesions associated with cystic airspaces and patients with noncystic noncavitary lesions showed no significant difference in frequency of complications (overall: 40% [36/90] vs 38% [68/180], p = .79; major: 4% [4/90] vs 6% [10/180], p = .78; minor: 36% [32/90] vs 32% [58/180], p = .59), frequency of nondiagnostic biopsies (12% [11/90] vs 9% [16/180], p = .40), or diagnostic performance (accuracy: 94% [85/90] vs 97% [175/180], p = .50; sensitivity: 94% [76/81] vs 97% [160/165], p = .50; specificity: 100% [9/9] vs 100% [15/15]; p > .99), respectively. All false-negative results for malignancy in both groups occurred in patients with nondiagnostic CNB results. Among lesions associated with cystic airspaces that were resected after CNB (all malignant), the cystic airspaces most commonly represented tumor degeneration (22/31 [71%]). CONCLUSION. CT-guided CNB is safe and accurate for assessing pulmonary lesions associated with cystic airspaces. CLINICAL IMPACT. CNB may help avoid a missed or delayed cancer diagnosis in pulmonary lesions with cystic airspaces.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Balbi M, Capelli S, Caroli A, et al. CT-Guided Core Needle Biopsy of Pulmonary Lesions Associated With Cystic Airspaces: A Case-Control Study. AJR Am J Roentgenol. 2024. PMID: 38717239. doi:10.2214/AJR.24.31042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。