外周性肺病变的对比增强影像:在超声引导活检中的作用
该多中心回顾性研究比较了活检前对比增强超声(CEUS)评估与常规超声引导下外周性肺病变经皮穿刺活检的组织充分性和诊断准确性。CEUS组组织充分性(98.2% vs 95.7%,P=0.03)和诊断准确性(96.9% vs 94.2%,P=0.04)更高,敏感性无显著差异(96.7% vs 94.0%,P=0.06)。倾向性评分匹配后,对于2-7cm病变,CEUS组组织充分性(99.0% vs 95.7%,P=0.04)和诊断准确性(98.5% vs 92.9%,P=0.006)更高;大于7cm病变两组无差异。
要点
- 活检前CEUS评估可提高2-7cm外周性肺病变穿刺活检的组织充分性和诊断准确性。
- 对于大于7cm的病变,CEUS与常规超声引导的活检性能无显著差异。
- CEUS组与常规超声组的活检敏感性无显著差异(96.7% vs 94.0%,P=0.06)。
核心结论
- 对于2-7cm的外周性肺病变,活检前CEUS评估较常规超声引导可显著提高组织充分性和诊断准确性;大于7cm病变两组活检性能相似。
研究设计与样本
- 多中心回顾性研究,纳入2017年1月至2022年10月接受超声引导下经皮穿刺活检的外周性肺病变患者,共分析1027个病变,常规超声组634例(平均年龄59.4岁±13.0,男性413例),CEUS组393例(平均年龄61.2岁±12.5,男性270例),采用倾向性评分匹配(最近邻匹配法)。
诊断标准与关键数值
- CEUS组组织充分性98.2% vs 常规超声组95.7%(P=0.03)。
- CEUS组诊断准确性96.9% vs 常规超声组94.2%(P=0.04)。
- CEUS组敏感性96.7% vs 常规超声组94.0%(P=0.06),无显著差异。
- 倾向性评分匹配后(每组358例),2-7cm病变CEUS组组织充分性99.0% vs 常规超声组95.7%(P=0.04)。
- 倾向性评分匹配后(每组358例),2-7cm病变CEUS组诊断准确性98.5% vs 常规超声组92.9%(P=0.006)。
临床应用与阅片要点
- 对于2-7cm的外周性肺病变,活检前进行CEUS评估可能有助于提高组织充分性和诊断准确性。
- 对于大于7cm的外周性肺病变,CEUS评估与常规超声引导的活检性能相似。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare the tissue adequacy and diagnostic accuracy of US-guided biopsies of peripheral pulmonary lesions (PPLs) with and without contrast agents. Materials and Methods A retrospective study was conducted at four medical centers in patients with PPLs who underwent US-guided percutaneous transthoracic needle biopsy (PTNB) between January 2017 and October 2022. The patients were divided into contrast-enhanced US (CEUS) and US groups based on whether prebiopsy CEUS evaluation was performed. Tissue adequacy and the diagnostic accuracy of PTNB, stratified by lesion size, were analyzed and compared between groups. A propensity score matching (PSM) analysis was conducted using the nearest-neighbor matching method. Results A total of 1027 lesions were analyzed, with 634 patients (mean age, 59.4 years ± 13.0 [SD]; 413 male) in the US group and 393 patients (mean age, 61.2 years ± 12.5; 270 male) in the CEUS group. The CEUS group produced more acceptable samples than the US group (98.2% vs 95.7%; P = .03) and achieved higher diagnostic accuracy (96.9% vs 94.2%; P = .04), with no evidence of a difference in sensitivity (96.7% vs 94.0%; P = .06). PSM and stratified analyses (n = 358 per group) indicated higher tissue adequacy (99.0% vs 95.7%; P = .04) and diagnostic accuracy (98.5% vs 92.9%; P = .006) in the CEUS group compared with the US group for 2-7-cm PPLs but not for lesions larger than 7 cm. Conclusion PTNB with prebiopsy CEUS evaluation demonstrated significantly better tissue adequacy and diagnostic accuracy compared with US guidance alone for PPLs ranging from 2 to 7 cm, with similar biopsy performance achieved between groups for lesions larger than 7 cm. Keywords: Contrast Material, Thoracic Diseases, Ultrasonography, Image-Guided Biopsy © RSNA, 2024.
引用
- Wang XY, Yuan ZF, Gan KH, et al. Contrast-enhanced Imaging in Peripheral Pulmonary Lesions: The Role in US-guided Biopsies. Radiol Cardiothorac Imaging. 2024. PMID: 38695742. doi:10.1148/ryct.230234
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。