胸部CT影像组学用于判定儿童肺炎支原体肺炎大环内酯类耐药相关基因突变状态:一项双中心研究
本研究回顾性纳入两家机构的258例肺炎支原体肺炎患儿,从胸部CT病灶提取影像组学特征,建立逻辑回归和随机森林模型判定23S rRNA基因突变状态。训练集五折交叉验证平均AUC分别为0.868和0.941,外部测试集AUC分别为0.855和0.815。胸部CT影像组学可能成为判定大环内酯类耐药基因突变状态的有前景的诊断工具。
要点
- 影像组学模型基于胸部CT病灶的8个特征判定23S rRNA基因突变状态。
- 训练集五折交叉验证平均AUC:逻辑回归0.868,随机森林0.941。
- 外部测试集AUC:逻辑回归0.855,随机森林0.815。
核心结论
- 胸部CT影像组学是判定肺炎支原体肺炎大环内酯类耐药基因突变状态的有前景的诊断工具。
研究设计与样本
- 回顾性纳入两家机构的258例肺炎支原体肺炎患者,训练集为第一机构194例,外部测试集为第二机构64例。
- 以鼻咽拭子聚合酶链反应检测23S rRNA基因突变状态为参考标准。
- 从半自动勾画的肺部病灶胸部CT图像中提取影像组学特征,经特征降维后采用逻辑回归和随机森林算法建模,训练集五折交叉验证,外部测试集验证。
诊断标准与关键数值
- 影像组学特征选择后保留8个特征。
- 训练集五折交叉验证平均AUC:逻辑回归模型0.868(95%CI:0.813-0.923),随机森林模型0.941(95%CI:0.907-0.975)。
- 外部测试集AUC:逻辑回归模型0.855(95%CI:0.758-0.952),随机森林模型0.815(95%CI:0.705-0.925)。
临床应用与阅片要点
- 原文结论认为胸部CT影像组学是判定肺炎支原体肺炎大环内酯类耐药基因突变状态的有前景的诊断工具。
- 原文未据此给出具体的临床推荐或阅片流程建议。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The mutations in the 23S ribosomal RNA (rRNA) gene are associated with an increase in resistance to macrolides in children with Mycoplasma pneumoniae pneumonia (MPP). This study aimed to develop and validate a chest computed tomography (CT) radiomics model for determining macrolide resistance-associated gene mutation status in MPP.
MATERIALS AND METHODS: A total of 258 MPP patients were retrospectively included from two institutions (training set: 194 patients from the first institution; external test set: 64 patients from the second). The 23S rRNA gene mutation status was tested by nasopharyngeal swab polymerase chain reaction. Radiomics features were extracted from chest CT images of pulmonary lesions segmented with semi-automatic delineation. Subsequently, radiomics feature reduction was applied to identify the most relevant features. Logistic regression and random forest algorithms were employed to establish the radiomics models, which were five-fold cross-validated in the training set and validated in the external test set.
RESULTS: The radiomics feature selection resulted in eight features. After five-fold cross-validation in the training set, the mean areas under the receiver operating characteristic curve (AUCs) of the logistic regression and random forest models were 0.868 (95% confidence interval (CI): 0.813-0.923) and 0.941 (95% CI: 0.907-0.975), respectively. In the external test set, the corresponding AUCs were 0.855 (95% CI: 0.758-0.952) and 0.815 (95% CI: 0.705-0.925).
CONCLUSION: Chest CT radiomics is a promising diagnostic tool for determining macrolide resistance gene mutation status in MPP.
AVAILABILITY OF DATA AND MATERIAL: The datasets generated or analyzed during the study are available from the corresponding author on reasonable request.
引用
- Wang H, Zhao L, Yang Y, et al. Chest Computed Tomography Radiomics for Determining Macrolide Resistance-Associated Gene Mutation Status in Children with Mycoplasma pneumoniae Pneumonia: A Two-Center Study. Acad Radiol. 2024. PMID: 38772798. doi:10.1016/j.acra.2024.05.008