文献速递神经MR

三维T1加权涡轮自旋回波血管内强化征与大脑中动脉粥样硬化管腔内血栓的关系

Relationship between the intravascular enhancement sign on three-dimensional T1-weighted turbo spin echo and intraluminal thrombus in middle cerebral artery atherosclerosis.
PubMed 文献 · Eur J Radiol · 2024-05-03

回顾性分析132例患者194个大脑中动脉斑块的高分辨磁共振血管壁成像数据,发现血管内强化征(IVES)血管数与信号强度比(SIR)是管腔内血栓(ILT)的独立相关因素,两者联合诊断ILT的AUC为0.89。

要点

  • IVES血管数(OR=1.089)与SIR(OR=0.007)是ILT的独立相关因素。
  • IVES血管数诊断ILT的AUC为0.81,SIR的AUC为0.88,两者联合AUC为0.89。
  • 伴ILT的粥样硬化斑块强化程度更高、狭窄更重、重构比更低。

核心结论

  • IVES血管数和SIR是ILT的独立危险因素,可能为粥样硬化性狭窄患者卒中预防提供新的监测靶点。

研究设计与样本

  • 回顾性分析2021年5月至2023年5月行HR-VWI的患者数据,共132例患者194个MCA斑块,评估临床信息、IVES血管数、狭窄程度、ILT、3D T1加权涡轮自旋回波序列斑块特征及3D TOF MRA的SIR,行相关和logistic回归分析。

关键影像表现/征象

  • 伴ILT较不伴ILT的粥样硬化缺血事件发生率更高、斑块强化程度和狭窄程度更高、IVES血管数更多。
  • 伴ILT较不伴ILT的斑块重构比、管腔面积、管壁面积、总血管面积和SIR更低。

诊断标准与关键数值

  • IVES血管数诊断ILT的AUC为0.81(95%CI 0.75-0.87,P<0.001)。
  • SIR诊断ILT的AUC为0.88(95%CI 0.82-0.94,P<0.001)。
  • IVES联合SIR诊断ILT的AUC为0.89(95%CI 0.84-0.94,P<0.001)。
  • 多因素logistic回归示IVES血管数与ILT相关OR=1.089(95%CI 1.013-1.170,P=0.020),SIR与ILT相关OR=0.007(95%CI 0.0004-0.124,P<0.001)。

临床应用与阅片要点

  • 阅片时可关注3D T1加权涡轮自旋回波序列上的IVES血管数及TOF MRA的SIR,两者与ILT独立相关。
  • IVES血管数增多和SIR降低可能提示ILT存在,联合两者诊断ILT的AUC达0.89。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the association between the intravascular enhancement sign (IVES) and intraluminal thrombus (ILT) detected by high-resolution magnetic resonance vessel wall imaging (HR-VWI) in patients with middle cerebral artery (MCA) atherosclerosis.

METHOD: The data of patients who underwent HR-VWI between May 2021 and May 2023, including clinical information, the number of IVES vessels, stenosis degree, ILT, plaque features on 3D T1-weighted turbo spin echo sequences, and signal intensity ratio (SIR) on 3D time-of-flight magnetic resonance angiography, were retrospectively analyzed. Correlation and logistic regression analyses were performed.

RESULTS: A total of 194 MCA plaques were identified in 132 patients (103 [53 %] on the left). Atherosclerosis with, relative to without, ILT was associated with a higher incidence of ischemic events, higher plaque enhancement and stenosis degrees, more vessels with IVES, and lower remodeling ratio, lumen area, wall area, total vessel area, and SIR. Multivariate logistic regression analysis showed significant and independent associations of the number of IVES vessels (OR = 1.089; 95 % CI [1.013-1.170]; P = 0.020) and SIR (OR = 0.007; 95 % CI [0.0004-0.124]; P < 0.001) with ILT. The number of vessels with the IVES (AUC = 0.81, 95 % CI [0.75-0.87]; P < 0.001) and SIR (AUC = 0.88, 95 % CI [0.82-0.94]; P < 0.001) sufficiently diagnosed ILT, and the AUC of the combination of the IVES and SIR was 0.89 (95 % CI [0.84-0.94]; P < 0.001).

CONCLUSION: The number of IVES vessels and SIR are independent risk factors for ILT. They may provide new monitoring targets for stroke prevention in patients with atherosclerotic stenosis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ouyang F, Liu J, Wu Q, et al. Relationship between the intravascular enhancement sign on three-dimensional T1-weighted turbo spin echo and intraluminal thrombus in middle cerebral artery atherosclerosis. Eur J Radiol. 2024. PMID: 38714134. doi:10.1016/j.ejrad.2024.111495

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。