应用CT灌注氧代谢率定量急性缺血性卒中患者的梗死核心体积
本研究纳入76例急性缺血性卒中患者,在CT灌注上自动生成CMRO2与CBF图,以治疗前DWI梗死核心体积为参考,比较rCMRO2<20%-30%与rCBF<30%的定量表现。rCMRO2<26%与DWI的梗死核心体积差最小、95%一致性界限最窄、ICC最大(0.936),Bland-Altman体积偏差为1.96 mL,而rCBF<30%的偏差为14.10 mL。作者认为CT灌注衍生的CMRO2是估测急性缺血性卒中梗死核心体积的有前景参数。
要点
- rCMRO2<26%与DWI梗死核心体积的ICC为0.936,体积偏差1.96 mL。
- rCBF<30%与DWI的体积偏差为14.10 mL,大于rCMRO2<26%。
- CT灌注衍生CMRO2是估测梗死核心体积的有前景参数。
核心结论
- CT灌注衍生的CMRO2是估测急性缺血性卒中患者梗死核心体积的有前景参数。
研究设计与样本
- 研究纳入76例符合入组标准的急性缺血性卒中患者(平均年龄69.97±12.15岁,43例男性),由后处理软件自动生成CT灌注的CMRO2与CBF图,以治疗前DWI衍生的梗死核心体积为参考标准。
诊断标准与关键数值
- 以治疗前DWI衍生的梗死核心体积为参考,rCMRO2<26%在备选阈值中平均梗死核心体积差最小、95%一致性界限最窄、ICC最大(ICC=0.936)。
- Bland-Altman分析显示DWI与rCMRO2<26%之间的体积偏差为1.96 mL。
- DWI与rCBF<30%之间的体积偏差为14.10 mL,rCBF<30%的ICC为0.934。
临床应用与阅片要点
- 作者认为CT灌注衍生的CMRO2是估测急性缺血性卒中梗死核心体积的有前景参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The cerebral metabolic rate of oxygen (CMRO2) is considered a robust marker of the infarct core in 15O-tracer-based PET. We aimed to delineate the infarct core in patients with acute ischemic stroke by using commonly used relative CBF (rCBF) < 30% and oxygen metabolism parameter of CMRO2 on CT perfusion in comparison with pretreatment DWI-derived infarct core volume.
MATERIALS AND METHODS: Patients with acute ischemic stroke who met the inclusion criteria were recruited. The CMRO2 and CBF maps in CT perfusion were automatically generated by using postprocessing software. The infarct core volume was quantified with relative cerebral metabolic rate of oxygen (rCMRO2) <20% -30% and rCBF <30%. The optimal threshold was defined as those that demonstrated the smallest mean absolute error, lowest mean infarct core volume difference, narrowest 95% limit of agreement, and largest intraclass correlation coefficient (ICC) against the DWI.
RESULTS: This study included 76 patients (mean age ± standard deviation, 69.97 ± 12.15 years, 43 men). The optimal thresholds of rCMRO2 <26% resulted in the lowest mean infarct core volume difference, narrowest 95% limit of agreement, and largest ICC among different thresholds. Bland-Altman analysis demonstrated a volumetric bias of 1.96 mL between DWI and rCMRO2 <26%, whereas in cases of DWI and rCBF <30%, the bias was notably larger at 14.10 mL. The highest correlation was observed for rCMRO2 <26% (ICC = 0.936), whereas rCBF <30% showed a slightly lower ICC of 0.934.
CONCLUSIONS: CT perfusion-derived CMRO2 is a promising parameter for estimating the infarct core volume in patients with acute ischemic stroke.
引用
- Otgonbaatar C, Song H, Jung KH, et al. Quantification of Infarct Core Volume in Patients with Acute Ischemic Stroke Using Cerebral Metabolic Rate of Oxygen in CT Perfusion. AJNR Am J Neuroradiol. 2024. PMID: 38806237. doi:10.3174/ajnr.A8360
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。