基于T1WI图像的影像组学模型与深度学习模型用于急性淋巴细胞白血病识别
本研究利用604例儿童脑部T1WI图像,沿正中矢状位斜坡手动勾画兴趣区提取影像组学特征,并按9:1随机分为训练集与测试集,分别构建支持向量机影像组学模型和Efficientnet-B3深度学习模型。测试集中深度学习模型AUC为0.981,影像组学模型AUC为0.962,DeLong检验显示两模型无统计学差异(P>0.05),两模型对急性淋巴细胞白血病均表现出良好的诊断效能。
要点
- 深度学习模型在测试集AUC为0.981,影像组学模型为0.962,两者无统计学差异(P>0.05)。
- 影像组学模型准确度/敏感度/特异度分别为0.9180/0.9565/0.8947。
- 深度学习模型准确度/敏感度/特异度分别为0.9344/0.8696/0.9737。
核心结论
- 深度学习与影像组学模型在训练集和测试集中均显示高AUC值,对预测急性淋巴细胞白血病表现出良好的诊断效能。
研究设计与样本
- 研究纳入急性淋巴细胞白血病组与正常儿童组共604例脑部磁共振数据,由两名放射科医师独立沿T1WI正中矢状位斜坡手动勾画兴趣区后提取影像组学特征,按9:1比例随机分为训练集和测试集,训练集中采用相关系数大于0.99的特征以支持向量机分类构建影像组学模型,并以Efficientnet-B3网络模型接收训练集图像构建深度学习模型,在测试集中验证两种模型后计算敏感度、特异度和ROC曲线下面积以评估诊断效能。
诊断标准与关键数值
- 测试集中深度学习模型AUC为0.981,高于影像组学模型的0.962,DeLong检验显示两模型无统计学差异(P>0.05);影像组学模型准确度/敏感度/特异度/阴性预测值/阳性预测值分别为0.9180/0.9565/0.8947/0.9714/0.8462,深度学习模型分别为0.9344/0.8696/0.9737/0.9250/0.9524。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: This study aimed to develop highly precise radiomics and deep learning models to accurately detect acute lymphoblastic leukemia (ALL) using a T1WI image.
MATERIALS AND METHODS: A total of 604 brain magnetic resonance data of ALL group and normal children (NC) group. Two radiologists independently retrieved radiomics features after manually delineating the area of interest along the clivus at the median sagittal position of T1WI. According to the 9:1 ratio, all samples were randomly divided into the training cohort and the testing cohort. support vector machine was then used to classify the radiomics model using the features that had a correlation coefficient of greater than 0.99 in the training cohort. The Efficientnet-B3 network model received the training set images to create a deep learning model. The sensitivity, specificity, and area under the ROC curve were calculated in order to evaluate the diagnostic efficacy of the different models after the validation of two aforementioned models in the testing cohort.
RESULTS: The deep learning model had a higher AUC value of 0.981 than the radiomics model's value of 0.962 in the testing cohort. Delong's test showed no statistical difference between the two models (P>0.05). The accuracy/sensitivity/specificity/negative predictive value/positive predictive value achieved 0.9180/0.9565/0.8947/0.9714/0.8462 for the radiomics model and 0.9344/0.8696/0.9737/0.9250/0.9524 for deep learning model.
CONCLUSIONS: The deep learning and radiomics models showed high AUC values in the training and test cohorts. They also exhibited good diagnostic efficacy for predicting ALL.
引用
- Cai Q, Tang H, Wei W, et al. Radiomics model and deep learning model based on T1WI image for acute lymphoblastic leukemia identification. Clin Radiol. 2024. PMID: 38796378. doi:10.1016/j.crad.2024.04.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。