文献速递心血管US

基于人工智能的右向左分流分级自动评估方法:在生理盐水造影经胸超声心动图中的应用

An Artificial Intelligence-Driven Approach for Automatic Evaluation of Right-to-Left Shunt Grades in Saline-Contrasted Transthoracic Echocardiography.
PubMed 文献 · Ultrasound Med Biol · 2024-05-01

本研究基于174例受试者的23665帧生理盐水造影经胸超声心动图图像,训练EfficientNet-b4模型自动检测微泡并评估右向左分流分级;内部测试集准确率0.926、敏感度0.827、特异度0.951,外部验证集(33例隐源性缺血性卒中患者)准确率0.864、敏感度0.818、特异度0.909,均高于住院医师的0.727、0.636、0.818。作者认为该模型可快速、准确、易部署地用于右向左分流分级,有助于住院医师培训和减轻心脏科医师工作负荷。

要点

  • AI模型在内部测试集上评估右向左分流分级的准确率为0.926、敏感度0.827、特异度0.951。
  • 外部验证集(33例隐源性缺血性卒中患者)中AI模型准确率0.864、敏感度0.818、特异度0.909。
  • 住院医师评估的准确率0.727、敏感度0.636、特异度0.818,均低于AI模型。

核心结论

  • AI模型为生理盐水造影经胸超声心动图右向左分流分级提供了快速、精确且易于部署的方法,对常规临床实践有重要意义;住院医师可从该算法中获益,提高右向左分流诊断的准确性和效率。

研究设计与样本

  • 研究纳入174例受试者的23665帧生理盐水造影经胸超声心动图图像,按患者层面划分为训练集20475帧和内部验证集3190帧,另纳入33例隐源性缺血性卒中患者作为外部验证集;采用EfficientNet-b4模型进行右向左分流程度分类,以AUC、敏感度和特异度评估模型性能并与住院医师比较。

诊断标准与关键数值

  • 内部测试集:AI模型准确率0.926、敏感度0.827、特异度0.951;住院医师准确率0.727、敏感度0.636、特异度0.818。
  • 外部验证集:AI模型准确率0.864、敏感度0.818、特异度0.909;住院医师准确率0.727、敏感度0.636、特异度0.818。

临床应用与阅片要点

  • 作者认为该AI模型可用于自动检测生理盐水造影经胸超声心动图图像中的微泡并评估右向左分流分级,支持住院医师培训并减少心脏科医师工作量。
  • 作者指出生理盐水微泡在左心的识别对新手住院医师可能具有挑战性,可能延迟诊断和治疗,该AI工具有望辅助解决这一问题。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Intracardiac or pulmonary right-to-left shunt (RLS) is a common cardiac anomaly associated with an increased risk of neurological disorders, specifically cryptogenic stroke. Saline-contrasted transthoracic echocardiography (scTTE) is often used for RLS diagnosis. However, the identification of saline microbubbles in the left heart can be challenging for novice residents, potentially leading to a delay in diagnosis and treatment. In this study, we proposed an artificial intelligence (AI)-based algorithm designed to automatically detect microbubbles in scTTE images and evaluate right-to-left shunt grades. This tool aims to support residency training and decrease the workload of cardiologists.

METHODS: A dataset of 23,665 scTTE images obtained from 174 individuals was included in this study. This dataset was partitioned into a training set (n = 20,475) and an internal validation set (n = 3,190) on a patient-level basis. An additional cohort of 33 patients diagnosed with cryptogenic ischemic stroke was enrolled as an external validation set. The proposed algorithm for right-to-left shunt degree classification employed the EfficientNet-b4 model, and the model's performance was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity, and compared to the performance of residents.

RESULTS: Our AI model demonstrated robust performance with an accuracy of 0.926, sensitivity of 0.827, and specificity of 0.951 on the internal testing dataset. In the external validation set, our AI model exhibited diagnostic accuracy, sensitivity, and specificity of 0.864, 0.818, and 0.909, respectively. In comparison, residents achieved values of 0.727, 0.636, and 0.818, respectively.

CONCLUSION: Our AI model provides a swift, precise, and easily deployable methodology for grading the degree of right-to-left shunt in scTTE, carrying substantial implications for routine clinical practice. Residents can benefit from our artificial intelligence-based algorithm, enhancing both the accuracy and efficiency of RLS diagnosis.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Li Y, Chen H, Yang X, et al. An Artificial Intelligence-Driven Approach for Automatic Evaluation of Right-to-Left Shunt Grades in Saline-Contrasted Transthoracic Echocardiography. Ultrasound Med Biol. 2024. PMID: 38692941. doi:10.1016/j.ultrasmedbio.2024.03.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。