儿童烟雾病全麻下MR血氧水平依赖(BOLD)脑血管反应性评估
纳入28对检查(平均年龄7.3±4.0岁),评估全麻下BOLD-CVR成像的同日重复性。28对中18对(64.3%)的组内重复性达优秀至良好(≥0.59);重复扫描间灰质和白质CVR估计值无显著差异(所有P值>0.05);Bland-Altman图显示合理一致且无系统偏倚。结论:全麻下BOLD-CVR成像可重复评估烟雾病患儿的脑血管储备。
要点
- 全麻下BOLD-CVR在烟雾病患儿中同日重复性优秀至良好者占64.3%(18/28对)。
- 重复扫描间灰质和白质CVR估计值无显著差异(所有P值>0.05)。
- Bland-Altman图显示重复扫描间合理一致且无系统偏倚。
核心结论
- 全麻下BOLD-CVR成像可为烟雾病患儿提供可重复的脑血管储备评估。
研究设计与样本
- 同日重复性研究,纳入28对检查,平均年龄7.3±4.0岁;采用BOLD MRI脑血管反应性(CVR)成像,在全麻下进行;以ICC、Wilcoxon符号秩检验和Bland-Altman图评估扫描间变异性。
诊断标准与关键数值
- 28对检查中18对(64.3%)的组内重复性达优秀至良好(ICC≥0.59)。
- 重复扫描间灰质和白质CVR估计值无显著差异(所有P值>0.05)。
- Bland-Altman图显示正性和负性反应体素平均信号幅度及正性和负性CVR分数估计值的重复扫描间合理一致且无系统偏倚。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Moyamoya is a progressive, non-atherosclerotic cerebral arteriopathy that may present in childhood and currently has no cure. Early diagnosis is critical to prevent a lifelong risk of neurological morbidity. Blood-oxygen-level-dependent (BOLD) MRI cerebrovascular reactivity (CVR) imaging provides a non-invasive, in vivo measure of autoregulatory capacity and cerebrovascular reserve. However, non-compliant or younger children require general anesthesia to achieve BOLD-CVR imaging.
OBJECTIVE: To determine the same-day repeatability of BOLD-CVR imaging under general anesthesia in children with moyamoya.
MATERIALS AND METHODS: Twenty-eight examination pairs were included (mean patient age = 7.3 ± 4.0 years). Positive and negatively reacting voxels were averaged over signals and counted over brain tissue and vascular territory. The intraclass correlation coefficient (ICC), Wilcoxon signed-rank test, and Bland-Altman plots were used to assess the variability between the scans.
RESULTS: There was excellent-to-good (≥ 0.59) within-day repeatability in 18 out of 28 paired studies (64.3%). Wilcoxon signed-rank tests demonstrated no significant difference in the grey and white matter CVR estimates, between repeat scans (all p-values > 0.05). Bland-Altman plots of differences in mean magnitude of positive and negative and fractional positive and negative CVR estimates illustrated a reasonable degree of agreement between repeat scans and no systematic bias.
CONCLUSION: BOLD-CVR imaging provides repeatable assessment of cerebrovascular reserve in children with moyamoya imaged under general anesthesia.
引用
- Choi EJ, Levin D, Robertson A, et al. Assessment of MR blood-oxygen-level-dependent (BOLD) cerebrovascular reactivity under general anesthesia in children with moyamoya. Pediatr Radiol. 2024. PMID: 38777883. doi:10.1007/s00247-024-05930-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。