如何精准命中过敏靶点:淋巴结内免疫治疗的批判性评价与超声引导注射的实用建议

How to hit the allergy target: A critical appraisal of intralymphatic immunotherapy with practical recommendations on ultrasound-guided injections.
指南 / 共识 · Allergy · 2024-05-07

该研究回顾分析28例女性与32例男性共173次超声引导淋巴结内免疫治疗注射,发现针尖斜面全长未刺入淋巴结时药液会反流至间质,选择更浅表淋巴结及更小角度进针可显著改善超声下针道可见性,持续练习与注射准确性相关,作者据此提出淋巴结选择与探头、针具操作的实用建议。

要点

  • 针尖斜面全长必须刺入淋巴结,否则药液反流至间质。
  • 选择更浅表淋巴结并以更小角度进针可改善超声下针道可见性。
  • 持续练习与更准确的淋巴结内注射及针道可见性改善相关。

核心结论

  • 正确将针尖置于淋巴结内最为关键;针尖斜面未全长刺入淋巴结时可见药液反流至间质;选择更浅表淋巴结并减小进针角度可显著改善超声下针道可见性;持续练习与更准确的注射及更好的针道可见性显著相关;作者基于结果与经验提出淋巴结选择及超声探头、针具操作的若干建议。

研究设计与样本

  • 回顾性分析173次超声引导淋巴结内免疫治疗注射,对象为28例(47%)女性与32例(53%)男性,中位年龄29岁(21-59岁),记录注射位置、针道可见性、药液释放及患者特征。

关键影像表现/征象

  • 针尖斜面全长未刺入淋巴结时,观察到药液反流至间质。
  • 选择更浅表淋巴结并以更小角度进针可显著改善超声下针道可见性。
  • 持续练习与更好的针道可见性及更准确的淋巴结内注射显著相关。

临床应用与阅片要点

  • 作者提出淋巴结选择及超声探头与针具正确操作的若干建议,以推进淋巴结内免疫治疗标准化与培训。
  • 作者认为淋巴结内免疫治疗的标准化与培训对实现良好安全性与有效性目标很重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Intralymphatic immunotherapy (ILIT) represents a promising novel approach treating allergic diseases. However, no standardized procedures or recommendations have been established or reported, despite the recognized fact that treatment efficacy relies on the ability to inject the allergen intranodally.

OBJECTIVE: We aim to provide a critical appraisal of ILIT as a method of allergen immunotherapy and to deliver practical recommendations for accurate ILIT.

METHODS: One hundred and seventy-three ILIT injections were performed in 28 (47%) women and 32 (53%) men with median age of 29 years (21-59). The injections were ultrasound-guided and recorded for retrospective analysis with respect to injection location, needle visibility, medication release, and patient characteristics.

RESULTS: The results show that the correct positioning of the needle within the lymph node (LN) was most critical. If the whole length of the needle bevel was not inserted into the LN, substance backflush into the interstitium was observed. Selecting a more superficial LN and inserting the needle at a smaller angle towards the LN significantly improved needle visibility in the ultrasound. Longitudinal results showed that continuous practice significantly correlated with improved needle visibility and more accurate ILIT injections.

CONCLUSION: Based on our results and practical experience, we propose several recommendations for LN selection and the correct handling of ultrasound probe and needle. We are confident that ILIT standardization and training will be important as to meet the goals of good safety and efficacy of ILIT.

来源:Allergy,查看原文。版权归原作者所有。