文献速递骨肌MR

深度学习重建用于快速自旋回波前瞻性加速踝关节MRI:多读者研究

Deep learning reconstruction for turbo spin echo to prospectively accelerate ankle MRI: A multi-reader study.
PubMed 文献 · Eur J Radiol · 2024-04-03

前瞻性纳入56例需行踝关节MRI的患者,比较常规TSE与前瞻性欠采样DLR-TSE序列。DLR-TSE总采集时间233秒,较常规TSE的547秒减少57.4%,整体图像质量更优、伪影更少、噪声更低,解剖细节区分、诊断信心及结构异常检出与常规TSE无差异,互换性分析显示诊断等效。

要点

  • DLR-TSE踝关节MRI总采集时间233秒,较常规TSE的547秒减少57.4%。
  • DLR-TSE整体图像质量更优、伪影更少、噪声更低(均P<0.05)。
  • 两种序列解剖细节区分、诊断信心及结构异常检出无差异,互换性分析示诊断等效。

核心结论

  • DLR可前瞻性加速常规TSE踝关节MRI至约4分钟综合检查水平,图像质量更优且病灶检出率相似。

研究设计与样本

  • 前瞻性研究,2023年3月至2023年5月纳入56例(平均年龄32.6±10.6岁,男35例),每例均行常规TSE与前瞻性欠采样DLR-TSE序列,由4名经验丰富的放射科医师独立评估。

关键影像表现/征象

  • DLR-TSE整体图像质量优于常规TSE,伪影更少、噪声更低(均P<0.05)。
  • DLR-TSE与常规TSE在解剖细节区分、诊断信心及结构异常评估方面无差异(P>0.05)。

诊断标准与关键数值

  • 图像质量采用5分制评估,涵盖整体图像质量、解剖细节区分、诊断信心、伪影和噪声。
  • 互换性分析涉及所有分析的结构异常,DLR-TSE相对常规TSE显示诊断等效。

临床应用与阅片要点

  • DLR-TSE可将踝关节MRI总采集时间从547秒缩短至233秒(减少57.4%),图像质量更优且结构异常检出与常规TSE等效。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate a deep learning reconstruction for turbo spin echo (DLR-TSE) sequence of ankle magnetic resonance imaging (MRI) in terms of acquisition time, image quality, and lesion detectability by comparing with conventional TSE.

METHODS: Between March 2023 and May 2023, patients with an indication for ankle MRI were prospectively enrolled. Each patient underwent a conventional TSE protocol and a prospectively undersampled DLR-TSE protocol. Four experienced radiologists independently assessed image quality using a 5-point scale and reviewed structural abnormalities. Image quality assessment included overall image quality, differentiation of anatomic details, diagnostic confidence, artifacts, and noise. Interchangeability analysis was performed to evaluate the equivalence of DLR-TSE relative to conventional TSE for detection of structural pathologies.

RESULTS: In total, 56 patients were included (mean age, 32.6 ± 10.6 years; 35 men). The DLR-TSE (233 s) protocol enabled a 57.4 % reduction in total acquisition time, compared with the conventional TSE protocol (547 s). DLR-TSE images had superior overall image quality, fewer artifacts, and less noise (all P < 0.05), compared with conventional TSE images, according to mean ratings by the four readers. Differentiation of anatomic details, diagnostic confidence, and assessments of structural abnormalities showed no differences between the two techniques (P > 0.05). Furthermore, DLR-TSE demonstrated diagnostic equivalence with conventional TSE, based on interchangeability analysis involving all analyzed structural abnormalities.

CONCLUSION: DLR can prospectively accelerate conventional TSE to a level comparable with a 4-minute comprehensive examination of the ankle, while providing superior image quality and similar lesion detectability in clinical practice.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Xie Y, Li X, Hu Y, et al. Deep learning reconstruction for turbo spin echo to prospectively accelerate ankle MRI: A multi-reader study. Eur J Radiol. 2024. PMID: 38593573. doi:10.1016/j.ejrad.2024.111451

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。